INSTALLATION INSTRUCTIONS
OCCUPANCY SENSOR,
VACANCY SENSOR
WALL SWITCH
OS150B
VS150
SPECIFICATIONS
Voltage .................................................................. 120VAC,60Hz
Fluorescent.........................................................................500VA
Motor ................................................................................1/8Hp
Incandescent ....................................................................... 500W
Time Delay ........................................................ 15Sec to 30Mins
Light Level................................................................ 30 Lux--Daylight
Operation Temperature....................................................... 32 F--131 F
DESCRIPTION
The passive infrared sensors work by detecting the difference between
heat emitted from the human body in motion and the background space.
The sensor switch can turn a load on and hold it as long as the sensor
detects occupancy. After no motion is detected for the set time delay, the
load turns off automatically.The sensor switch has one relay ( equal
to single pole switch), and also includes a Ambient Light Level Sensor.
Coverage Area
The coverage range of the sensor switch is specified and illustrated
in Figure 1. Large objects and some transparent barriers like glass
windows will obstruct the sensors' view and prevent detection, causing
the light to turn off even though someone is still in the detection area.
Top View
18'
9'
9'
Best: 260 sq.ft.
18'
Regular:650 sq.ft.
Maximum: 980 sq.ft.
Side View
5'
4'
15'
150
-01-
OS150B, VS150
WARNING:
INSTALLATION:
1. Connect lead wires as WIRING DIAGRAM (see Figure 2): Black lead to
Line(Hot), Red lead to Load wire, White lead to Neutral wire, Green
lead to Ground.
Wiring Diagram:
2. Gently position wires in wall box, attach sensor switch to the box.
3. Mount device "TOP" up.
4. Restore power at circuit breaker or fuse, wait
5. Remove the small cover plate (Illustrated in Figure 3).
6. Locate the adjustment knobs on the control panel to perform test
and adjustment (Illustrated in Figure 3).
7. Replace the small cover plate after testing and adjustment.
8. Attach the wallplate.
Figure 1
30'
Turn off the circuit breaker before installation.
Indoor use only.
Do not exceed electrical ratings.
OS150B / VS150
Neutral
White
Hot
Load
LOAD
Black
Red
Ground
Neutral(White)
Green
Figure 2
one minute.
Figure 3
0 -
- 2
ADJUSTMENT
Time Delay knob
Default position: 15 Seconds (Test mode)
Adjustable: from 15 Seconds to
30 Minutes (clockwise)
Sensor Sensitivity Range Knob
Default position: Center at 65%
(Position 4)
Adjustable: 30% (Position 1) to 100%
Note: Turn toward right for greater room space.
Turn toward left to avoid false alert in smaller room and near
the doorway or heat source.
Ambient Light Level Knob
Default position: Daylight (100% at position 4)
Adjustable: Daylight to 30Lux (Counter clockwise)
Note: avoid wasting energy by turning on the light under daylight.
OPERATION
Push-button for OS150B
As illustrated in Figure 5, the Load stays Off when the button is
pushed in and locked. (switched Off)
As illustrated in Figure 6, the Load turns On after the button is
pressed and released.The sensor switch stays at the OCC Mode
until the button is pressed Off next time.
Press
(Lock)
OFF
Figure 5
VS150
Manual On/Off Button
By Pushing in the button, the Load can be turned On/Off as illustrated
in Figure 5.
Turning On
Manually turn On the Load by pushing the button whenever the Load is Off.
Turning Off
Manually turn Off the Load by pushing the button . Without pushing
the button, the Load is to be turned Off after set time delay.
Turning On Automatically
Only after the Load automatically turns Off, the Load can be turned On
automatically if occupancy detected within 30 seconds.
0 -
- 3
Figure 4
Press and release
AUTO
Figure 6

Advertisement

loading

Summary of Contents for NICOR MAXCOR OS150B

  • Page 1 INSTALLATION INSTRUCTIONS OS150B, VS150 ADJUSTMENT WARNING: Turn off the circuit breaker before installation. OCCUPANCY SENSOR, Time Delay knob Indoor use only. VACANCY SENSOR Do not exceed electrical ratings. Default position: 15 Seconds (Test mode) WALL SWITCH Adjustable: from 15 Seconds to 30 Minutes (clockwise) INSTALLATION: Sensor Sensitivity Range Knob...