  • Page 1 Burglar Alarm System...
  • Page 2: Table Of Contents

    Table of Content 1.1General Description------------------------------------------------------------------ - 1 - 2.2System Setup------------------------------------------------------------------------- - 3 - 2.2.1Panel Setup------------------------------------------------------------------------- - 3 - 2.2.2Connections of Cables----------------------------------------------------------- - 3 - 2.2.3SIM Card installation------------------------------------------------------------ - 3 - 3.1Alarm Panel Initial Setup------------------------------------------------------------ 4 - 3.2Add Remote Control:---------------------------------------------------------------- 5 - 3.3Delete the remote control:---------------------------------------------------------- - 5 - 3.4Add detector-------------------------------------------------------------------------- - 5 - 3.5Delete detector----------------------------------------------------------------------- - 5 -...
  • Page 3: General Description

    The system is at a fully ready status where all detectors are activated in a working state, when the some events ( burglar, fire, gas leak, etc ) happened and detected, , alarm system alarm right away. In a ARM status, the panel [ ARM ] light is on, LCD screen show "ARM" is also on.
  • Page 4: System Setup

    In a DISARM status, the panel [ ARM ] light is off, LCD screen show " DISARM " ison. To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once. EMERGENCY When an emergency occurs, press emergency button on the remote or the * /SOS button...
  • Page 5: Alarm Panel Initial Setup

    3.1 Alarm Panel Initial Setup Load the SIM Card, fix the GSM Antenna, connect the power and other cables if any, then power up alarm panel. The alarm panel voice prompt "Welcome to use alarm system", and start self-test the GSM network, LCD shows "GSM signal"...
  • Page 6: Add Remote Control

    3.2 Add Remote Control: Press "#" key to enter the configuration mode: Syntax: 07+(00~99)+# to configure remote control Example: 07 then press 01# , to configure the 1st remote control. then press any key of the remote control to send a signal to the alarm panel, panel beep twice means successful, beep only once means the remote control has been configured before.
  • Page 7: Commands For Configuration

    The status LED is lit on the panel to indicate at the configuration mode, the status light is off upon exit. 4.1 Commands for Configuration Set up voice alarm To set the 1st group to the 9th group of voice alarm phone number phone number 【...
  • Page 8 Set phone number to To set the first group to the sixth group of phone number for SMS receive SMS message message. When alarm panel is alert, it sends a SMS message to the six sets of numbers one by one. Syntax: Example: If the user wants to set 13812345678 SMS for the first group of 【4】...
  • Page 9 then press # to exit setup. Method two: After calling and connected to the panel from remote, press 5260#. Method three: Send SMS message 12345260# Set length of Siren Set alarm length of sounding when panel alarm, could be set to 0-20 sound minutes, factory default is 1 minute.
  • Page 10 【 Number week 】+ 5702120013001234567#, * then press # to exit Setup. 【 # 】 Method two: After calling connected panel from remote, press 57012200070012345,then press5702120013001234567# Method three: Send message 123457012200070012345# 12345702120013001234567# SMS Send ON/OFF [0/1]: 0 means OFF,1 means On\N. Default is OFF When Accessory’s E.g.
  • Page 11 Syntax: 0 means NO and 1 means NC 【 61 】 + 【 zone NO means short-circuit to alarm number 51-54 】 + NC means open-circuit to alarm Example: Set 51 zone to NC, 【0/1 】+ 【# 】 Method one: # Key enters the configuration mode, press 61511# * Then press # To exit Setup.
  • Page 12: Commands Of System Enquiries

    Method one: Syntax: 【14 】 + 【 00-99 】 # , and then press 1450# , press the * then press # Exit Setup + 【 # 】 Method two: After calling and connected to the panel from remote, press 1450# Method three: Send SMS message 12341450# Keyboard...
  • Page 13 alarm phone number phone number on the alarm panel for SMS messages. Press alarm panel query key of your keyboard, then blinking status LED on Syntax: and then press 41#, the alarm panel LCD show 13812345678 means the 4+【 1-6 】 + 【 # 】 first set of SMS message is 13812345678 Query password Used to query the current password of the alarm panel , Press alarm panel...
  • Page 14: Sms Commands

    9901+【 # 】 Other indications as: JP = arm/disarm from keyboard YC = arm/disarm from remote tP = interference alert 01 = remote control number 1 Query alarm panel alarming records The system can save up to the most recent 102 alarming records. Syntax: Press alarm panel query key of your keyboard, then blinking status LED on 9900+【...
  • Page 15 11+ 【# 】 Arming → arm status Relay out off → relay off Alarm out on →integrated alarm on Send SMS on→SMS messaging on Remote set on→remote operation on Password:1234→the password is 1234 Alarm delay:00s→delay alarming 0 second Arm delay:00s→ delay arm 0 second Siren on 1 min→...
  • Page 16: After Receiving The Panel Alert

    80+ 【00-99 】+ "Panel Used to customize the SMS message for zone 00-99. with SMS message"+ Example: Send message “12348001 Front Door Alarm#” to the alarm panel will set alarm panel to send SMS message “Front Door Alarm” upon 【# 】 zone 01 alarm being triggered.
  • Page 17: Definitions Of Zones

    Input voltage: DC9V-12V Standby currents: < 25 mA Alarm current: < 450 mA Wireless frequency: 315/433MHZ , 2262/1.5-4.7M , EV1527/300K  GSM Format: Support GSM850/900/1800/1900MHz (option) Backup battery: Lithium battery DC7.2V  Alarm loudness: 110dB  Detailed parameters: The alarm should be compatible with PT2262, PT2240 and EV1527. Using PT2262 encoding, the resistance is recommended 1.5M-4.7M;...
  • Page 18 After download APP in smart phone, user need to register in APP, click “Register” button to go to register interface. User can choose phone number or email and enter password, then click“ Register” to save settings. Then user can log-in the APP to do operation.