Series MG.., MG..A, MG..A..C (no explosion protection)
Series MG..Xn, MG..A..Xn, MG..A..C..Xn (with
for the intended use in zone 2) in accordance with
2014/34/EU (ATEX 95))
Solenoid drive MG 004 – 008
Unscrew hexagonal head screw (900) and remove it including insulating bush (401*). Remove cover
of solenoid housing (105*) from solenoid housing (103). Loosen and remove connecting bolt (501).
Solenoid drive volume control butterfly valve
Loosen protective cap (505) and remove including o-ring (403*). Remove cover of solenoid housing (105*)
from solenoid housing (103). Unscrew and remove hexagonal nut (901).
Pos.
UNI-Geräte E. Mangelmann Elektrotechnische Fabrik GmbH
Holtumsweg 13, D-47652 Weeze, Tel. +49 2837/9134-0, Fax. +49 2837/1444
www.uni-geraete.de info@uni-geraete.de
Seite 4 / 14
- protection
Solenoid drive MG 010 – 020
I
tem
Description
103
Solenoid housing
106
Upper part of housing
500
Magnet plate
501
Connecting bolt
701
Cable gland
702
Solenoid
714
Mains outlet
800
Solenoid drive
900
Hexagonal head screw
901
Hexagonal nut
1004
Casting compound
TM 4021
220.100.038-18