Index User Menu 1 ........16 General considerations ......3 User Menu 2 ........17 Symbology ........3 2Ways2+ Remote Command ....20 Use ..........3 Control panel ........21 Packaging of documentation ....3 9.2.1. The keys ........21 Security warnings ........3 9.2.2. Menu ........
documentation must attached forwarded to the new user/owner. 1. G ENERAL CONSIDERATIONS 2. S ECURITY WARNINGS TEK Biomasse ® is a registered trademark, whose conditioning equipment manufactured by Vitor Monteiro Lda. The instructions contained in this manual must tested in accordance with European reference be followed, both by the Technician (Installer, safety standards.
• Ensure that the equipment installation User site complies with all national and European regulations/laws; Before using for the first time, the user must read this manual in its entirety and bear in • Ensure the use of all personal protective mind the following: equipment;...
• When in operation, the boiler has very • Damage caused during transport or surfaces, should handling; approach or touch these, with special • Failure of components resulting from emphasis glass door, improper use or negligence, lack of chimney, among other elements; maintenance, installation in violation of •...
Technical Fuel Information (Pellets) 5. F Diameter 100% pressed pine wood pellets certified according to the EN PLUS A1 standard are the Length 10 to 30 mm only fuel allowed for use in this boiler. Density in the bag min. 650 kg/m The pellets used must be certified and in accordance with EN Plus 14961 or 17225-2.
Pellet storage Installation constraints The functioning of the boiler largely depends It must be safeguarded that no mechanical on the quality and conservation conditions of exhaust fans or collective ventilation ducts are the pellets, for this reason they must be stored installed at the installation site.
combustible or flammable material and which Outside, you should put protection against rain are exposed to excessive heat from either the and wind. boiler chimney, particularly when Safeguard the requirements and relating to crossing partitions and false ceilings. In these ventilation and air supply referred to.
parameters such as air intake and pellet loading, it will imply the installation of an air Smoke evacuation duct intake valve to the chimney. The smoke discharge from the boiler is with If necessary, contact the technical assistance positive pressure in relation to the surrounding service.
Hydraulic installation The boilers for central heating are equipped with a complete hydraulic kit, equipped with a 2 bar safety valve, circulator pump and a 6 liter expansion vessel. The connection to the hydraulic network must be carried out as shown in the image below. The safety valve must be connected to the sewer, taking into account that it must be properly siphoned.
NOTE: The volume of water in the installation in addition to the boiler water can be managed with the integrated 6 liter expansion vessel. However, the installer must safeguard for each installation, the need to install an additional expansion vessel, taking into account the total volume of the installation.
more detailed information points Safeguarding safety distance from 7.3and 16. combustible materials: see point 10- Boiler installation site. 7.9.1. Calculation Air supply and smoke evacuation: see points thermal power and average 7.4 - Air intake and 7.5 - Smoke evacuation duct.
in operation. This process requires that the Unplug the device from device is not performing any operations and the mains that the display shows “OFF”. Attention! Ensure that the device is not disconnected from the power supply when it is...
Messages Description of messages Code Viewing the status of the temperature probes. The message displayed in the probe Check-Up indicates that the temperature reading on one or more probes is equal to the minimum (0 °C) or maximum value (depends on the probe considered).
User Menu 1 Views By successively clicking on the P1 button, the display shows: tP: DHW temperature [°C] tF: Smoke temperature [°C] UF: Smoke extractor speed / Voltage [RPM / Volt] Co: Speed / Feeder ON time [RPM / sec ] PA: Water Pressure [ mbar ] FL: Primary airflow velocity St: Time remaining for maintenance 1 [h]...
User Menu 2 Access to the menu is done by pressing P3 and P4 at the same time for 3s This menu allows you to modify the value of the remote room thermostat, Thermostats or the temperature required for the DHW cylinder ( PuFF ) in a heating ( TerM ) installation that needs it.
Page 18
(MS). FiSe - Weekend: Allows you to set 3 programs for Monday-Friday (MF) and 3 programs for Saturday-Sunday (S S ). Instructions For each program it is necessary to define the start time and end time. DESCRIPTION display 1) Press the P2/P4 keys until the desired submenu Giorn and press the P3 key 2) Press the P2/P4 keys to select one of the 3...
Page 19
This menu is for setting the time and date. The upper display shows the hour and Clock ( oroL ) minutes, the lower display shows the day of the week. DESCRIPTION DISPLAY Press P3 key to enter edit mode. The hour, minute and day of week 0 7.
9. 2W 2+ R EMOTE OMMAND The radio remote control thermostat manages the operation of the boiler and monitors the operating status in real time. The main features are: • System remote control • Room thermostat • Management of operating and control parameters Attention: The system operates on the 868.3MHz ISM radio band.
Control panel 9.2.1. The keys Occupation Descriptive Turn the boiler on and off by pressing the button for 3 seconds On / Off Unlock System unlocks by pressing the key for 3 seconds Exit menu Enter Submenu, modify and save data Change room Radio thermostat temperature modification...
9.2.2. Menu To enter the menu press the SET key. A list of available submenus appears by pressing, selecting the desired submenu and pressing SET again, the desired parameters will be displayed: Submenu System Menu Auger Auger 1.0_________ Parameter code Auger______ Combustion Fan Combustion Fan 2...
9.2.4. User menu Menu Descriptive Combustion Power management Allows you to modify the combustion power of the system in pellet mode. It can be set to automatic or manual mode. In the first case, the system chooses the combustion power. In the second case, the user selects the desired power. The combustion mode (a = automatic combustion, m = manual combustion) and the system's working power level are indicated on the left side of the display.
Page 24
Current combustion recipe [ nr ] Revenue ( Only visible if >1) Product code Product Code: 537 FSYSI01000060.0.0 Firmware code and version Remote Control firmware code and FSYSC03000006.0.0 version Manual loading Function for filling the auger on the first start-up, or after a start-up failure due to an empty hopper.
Page 25
Radio Test This Menu is used to test the connection between the radio terminal and the boiler controller, thus checking the level of electromagnetic pollution. The Radio Terminal enters continuous transmission and counts correct and failed responses. The signal quality depends on the number of errors (misses). Change code (only if it is necessary to pair different boilers with different thermostats in the same area) Code change allows the remote control to be matched to the boiler, so that a...
Menu restore values Restore Factory Values parameters set by the manufacturer Chrono Menu Menu to set the start and end time of work in heating mode. 9.3.1. Modality To turn the system on using the chrono, select the mode after programming the on and off times. Descriptive Keys Display...
Page 27
• Weekly: Program the times to turn the system on and off (there are 3 time intervals). This mode runs 3 time intervals from Monday to Sunday Schedule Weekly Mon-Sun Daily Weekly 09:30 11:15 Weekend 00:00 00:00 00:00 00:00 • Weekend: Choose between 'Monday-Friday' and 'Saturday and Sunday'.
NSTALLING AND CONFIGURING THE System architecture The architecture includes three macrosystems: 4HEATModule ( Wikey or Pinkey ): hardware device that interacts with the TiEmme electronic control board and the local Wi-Fi router; SERVER CLOUD: web server infrastructure that allows data storage and works as a stellar hub for remote communication;...
Keys and LEDs on 4Heat modules Installation To test the device, perform the following procedures: Connect the 4HEATModule to the power supply: • WiKEY: make sure that the equipment (boiler, stove or stove) is connected to the network; • PinKEY: Wi-Fi led (a) fixed red; Connect the 4HEAT Module to the electronic board using the cable provided in the kit: •...
New 4HEAT module configuration Install the 4HEAT app available on the Play Store and App Store for free, to interact with the heating system. Connect your smartphone to your home Wi-Fi network and disconnect your mobile phone from the data connection. Also activate the GPS. When you open the application you are asked to select the language.
Page 31
7. Make sure that the smartphone is connected to the home Wi-Fi connection again and that the LEDs remain steady, allowing you to continue with the configuration phase. If the configuration procedure was not successful, you can reset the 4HEATModule by holding down the button for 10 seconds.
Connection to 4HEATModule In the "FIND DEVICE" section it is possible to connect to the 4HEATModule by entering the PIN code, only if the 4HEATModule is connected to the same Wi-Fi as the smartphone. You can also connect remotely (by connecting your smartphone data) by entering the access credentials of the 4HEATModule device already configured.
AINTENANCE Security measures Before starting maintenance work, make sure that boiler disconnected from electricity supply, that the boiler is cold and the Figure 11- Brazier ashes are extinguished. Put the brazier back in place ensuring the Turn off the main power switch located on the perfect alignment of the resistance hole with the rear panel, right side, and the corresponding respective resistance.
Page 34
Once the handle is placed horizontally, pull out the drawer. Carry out the same operation for the Clean the exchanger by opening the top cover. lower lid. Rotate the knobs as shown in the image. Dump the ash from the drawer, and with the aid of an ash vacuum cleaner, vacuum the ash compartments.
Note: For the boiler to work correctly and safely, both the drawer and the lid must be properly closed and watertight. To reassemble everything you just have to carry out the reverse process. To access the fume fan, loosen the six screws that secure the cover to the left side cover.
Remove the motor and clean the blades. To reassemble everything you just have to carry out the reverse process. Complete cleaning At least once a year, the boiler must be completely cleaned, completely eliminating ash other residues encrustations, especially those that occur in water models. This procedure great...
To facilitate cleaning, in particular all chimney Hydraulic installation encrustations, should appropriate maintenance pellets for cleaning at intervals. Annually, and when the installation is shut down, it is necessary to carry out the following checks: • Check the operation and efficiency of the safety valve.
RROR CODES Origin Cause Action Er01 Auger or boiler safety The water is not circulating. Check the installation. thermostat Circulator pump blocked with Wait for the boiler or It occurs if the hopper (85ºc) dirt, installation with air in hopper to cool down or boiler (95ºc) limit the circuit, or closed radiator and for the message...
Page 39
installation. Er10 Water pressure sensor Check the auto-fill valve, it To check for the lack of Occurs if the water pressure may be blocked. expansion capacity, set exceeds the value of 2.4 bar The installation does not have the pressure with the an expansion vessel capable boiler cold at 1.2 bar, of accumulating the...
Page 40
Er42 Air flow/mass sensor Maximum air flow reached, The use of swivels or During the Check Phase Up excessive chimney draft. fans in the chimney is the boiler makes the exhaust not allowed. capacity diagnosis. The maximum reference value has been exceeded Er44 Open door error Check door lock or ash...
IAGRAM OTHER POSSIBLE DIAGRAMS (CONSULT THE MANUFACTURER IN ADVANCE) The boiler allows other types of hydraulic configurations. These configurations are optional and must be requested at the time of ordering, by means of a quote. These settings imply that the start-up is carried out exclusively by a technician of the Tek Biomasse brand, Figure 14- Possible installation diagrams upon quotation...
Page 43
• Without DHW Installation is simple, requiring no additional elements. The ambient temperature probe located at the back of the boiler can be extended into the interior of the house. Using the chrono function and this probe inside the room and activating the ECO mode, the boiler will work for the programmed period, turning off whenever the room temperature is reached and turning it on again when it drops by 1ºC.
Page 44
• With DHW The boiler can produce DHW independently of heating. It can also work with an ambient thermostat for start and stop. To do this, connect the thermostat dry contact to the Remote input located on the rear panel. For the autonomous production of DHW, connect the cylinder thermostat (dry contact) to the cables with indication of DHW Thermostat.
Page 45
• With DHW and underfloor heating Figure 17- Scheme with inertia deposit with DHW, and Clima 610 Configuration not provided in a standard product, subject to order and on-site parameterization by the brand's technician. It implies the separate purchase of the Clima 610 unit for operation of the secondary circuit devices.
ODELS AND TECHNICAL CHARACTERISTICS PIKO Models Pot term Pot term Nominal reduced Weight Height 1280 Width Depth Heating volume 17.1 4.95 Thermal power 18.3 6.01 1.06 Pellet kg/h 1.37 consumption Autonomy 43.8 Performance % CO to 13% O 0.01 0.01 Mass flow of 14.6 8.47...
Page 48
Authorized Agent Office and Factory 1: Factory 2: Estrada dos Guilhermes, 27 Moinho de Vento, 1-E 2405-012 Maceira LRA 2405-008 Maceira LRA Portugal Portugal Phone: +351 244 770 240 comercial@grupovm.pt...