ET1000 Sliding gate operator Commercial/industrial 1000kg mass support@et.co.za G&C Electronics cc. T/A ET Systems 15 Nelson Rd, Observatory, Cape Town, South Africa www.et.co.za Technical specifications may change without prior notice. All goods are subject to the standard factory warranty as laid out on the last page of this...
Page 2
WARNING TO THE INSTALLER. GENERAL SAFETY OBLIGATIONS. Caution! It is important for personal safety to follow all the instructions carefully. Incorrect installation or misuse may cause serious personal harm. Keep the instructions in a safe place for future reference. This product was designed and manufactured strictly for the use indicated in this documentation.
1.2. Technical specifications. Model ET 1000 Pow er supply 220Vac +/- 10% 50Hz Motor pow er 370W Absorbed Current Motor revolutions 1400 r/min Motor thermal protection Ambient temperature C to 55 Maximum gate w eight 1000kg Maximum gate travel resistance 15KgF...
2. Installation 2.1 Cable requirements. Intercom cable. As per manufacturer's spec. Safety infra red beams transmitter cable (0,5mm x 2) Safety infra red beams receiver cable (0,5mm x 4) Coutesy light cables 220Vac (1,5mm x 3) Earth spike cable (2,5mm x 1) Electrical supply 220Vac (2,5mm x 3) Loop detector feeder (1,5mm x 1 looped) Intercom cable.
2.2 Installation and adjustment. Position the base plate between 30 and 45mm away from the fascia of the gate. NB! Take care when determining the entry point for your cabling. 2.2.2 Installing the rack. (Ensure the rack tracks straight and true across the pinion gear. Where necessary make use of feathering spacers between the rack and gate fascia to compensate for bowed gates).
Page 7
Before installing the limit actuators on the rack, the gearbox must be released into manual mode. To maneuver the gate by hand (manual mode). Slide the cover to the left as shown here. Then insert the release key supplied and turn fully clockwise. To change back to automatic mode (re-engaged) insert release key and turn fully anti-clockwise.
3. Control card. Set run time Set auto-close time Remote transmitter programming button LED 1 Set transmitter LED LED 2 Running state LED Transformer LED 3 Open limit LED LED 4 Close limit LED LED 5 Power LED Adjust load sensing for crawl speed 10 VR2 Adjust load sensing for running speed 11 J3...
Page 10
3.3 SETTING THE RUN TIME. After installing and completing the wiring, (Swap motor wires L1 and L2 if motor runs in the wrong direction). Power up Press and hold P1 for 3 sec. a. Gate will begin running OPEN b. On reaching the OPEN (Blue) limit the gate will begin running CLOSED On reaching the CLOSED (Red) limit the run time programming is complete.
Page 11
3.6 DIPSWITCH SELECTION. Function Autoclose Condo/loop Soft Stop Soft start Dipswitch 1 (Auto-close) Use safety infra Red Beams when activating this function! On – Automatic closing active. (See 3.4 above to program required Auto-close time). Off – Automatic closing not active. Dipswitch 2 (Condominium/loop detector mode) Must be used when connecting a loop detector.
Page 12
LED1 Flashes Meaning Successful - first user programmed. Master remote transmitter . Successful - There is still memory available. Multiple rapid flashes Unsuccessful - Memory is full (Add a RXCONDO receiver) Unsuccessful - Either a non - ETBLUE remote transmitter No flashes is being used or there is another remote transmitter active on 433.92MHz and it is blocking the signal.
Page 13
Faulty goods will be repaired or replaced at the sole discretion of ET Systems free of charge. This warranty is subject to the goods being returned to the premises of ET Systems. The carriage of goods is for the customers account. This warranty is only valid if the correct installation and application of goods, as laid out in the applicable documentation accompanying said goods, is adhered to.