Goodson VGL-100 Instructions

Valve guide level

Advertisement

Available languages

Available languages

VGL-100
Valve Guide Level
nstructions
VGL 100
Please read instructions before use.
VGL-100
VGL-101

Also available from Goodson:

LEV-8
8 inch Cylinder Head Level
LEV-8-1
Replacement Vial
LEV-12
12 inch Cylinder Head Level
LEV-12-1
Replacement Vial
Valve Guide Level
Replacement Vial
Reviewed June 2013

Calibration of Levels

Levels can be calibrated even on a non-level surface:
After purchase of a new level or the installation of a
new vial, place level on a flat surface. Adjust jam nuts
until you get bubble reading on the vial. Rotate level
180 degrees and adjust 1/2 of difference out of bubble
reading. Rotate level 180 degrees again, now bubble
should read exactly the same in both positions. You
may need to repeat this process 2-3 times to fine tune
level.
If you can adjust surface that you just calibrated level
on, adjust it so the bubble reads center of the vial, then
rotate level 180° to prove level repeats (Bubble staying
in the center).

How to adjust the VGL-100 Valve Guide Level

This level is un-calibrated when you receive it. Your
first step is to level machine bed as close as possible (by
eye). Set cylinder head in cradle with chamber side up.
Level by eye as close as possible. Set new level on top
of valve guide pilot. With level vial facing front to back
(position the end with 2 jam nuts facing you). Adjust
level of head or level vial until you can get some sort of
bubble reading. Rotate level 180°, just opposite of
where you started. Read where bubble is exactly, now
rotate level back to its original position. Noting the two
readings, adjust 1/2 of the difference of the two readings
out of the level itself by loosening and snugging the two
nuts on one end.
Even though the level may not read exactly in center it
is calibrated correctly when the readings 180° apart are
the same.
Double check this by rotating 90° from where you are
at. (Perpendicular to the previous placements). Read the
bubble, then rotate 180° from this point, if level is cali-
brated, the bubble will repeat its previous reading in the
new position. (Readings 180° apart will be the same if
the level is calibrated.)
Now to center bubble in level, re-adjust cylinder head
and pilot so bubble reads center. Then rotate level
through full circle (360°). The bubble should remain at
center, if not, repeat calibration process. (Remember
machine must be level to get your Level to read dead
center.)
Even if you are 1/8 of a line space off after calibration
this will be close enough to install guides properly.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VGL-100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Goodson VGL-100

  • Page 1 180° to prove level repeats (Bubble staying in the center). How to adjust the VGL-100 Valve Guide Level This level is un-calibrated when you receive it. Your first step is to level machine bed as close as possible (by eye).
  • Page 2 Ampolleta de Reemplazo nivel es calibrado.) Ahora para centralizar la burbuja en el nivel, re-ajuste la Tambien disponible de Goodson: cabeza del cilindro y el piloto para que la burbuja se lea en el centro. Despues gire el nivel un circulo entero...

This manual is also suitable for:

Vgl-101

Table of Contents