Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 1 Products covered by this manual 1.1 Approval note 1.2 Legal Notice 1.3 About Acura 2 Introduction 2.1 About this guide 2.2 Conventions used in this manual 2.3 Target audience 3 Introduction to equipment 4 Table of revisions 4.1 User guide table...
Page 3
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.2 Electrical connections - Reader 8.3 Electrical connections - PCI 8.4 Electrical connections - Ethernet LAN 8.6 Electrical connections - Digital input (Sensor) 8.7 Electrical connections - Relé 8.8 Reader visual indicators 8.8.1 STATUS visual indicator 8.9 POE Injector Visual Indicators Parte 2 - Operation and operation...
Page 4
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 11.1 TCP/IP connections to receive tag readings 11.2 TCP/IP connection, disconnection, and reconnection logic 11.3 Format of reading results via TCP/IP and RS232 11.4 Syslog 12 Mensagens de Log do leitor - Syslog 13 Regional Regulations 13.1 Frequencies and operating region 13.2 RF reader power...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 1 Products covered by this manual This user guide belongs to the following product: Reader Code UHF READER ACURA EDGE-30R+ Autoid 100.644 PCI INTERFACE EDGE-30R + 100.647 ANTENNA SUPPORT MTI BR 66MM 100.320 POE POWER SUPPLY 15.4W 501.248...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Authorized Antenna General Characteristics of the Antenna Edge-30 R+. Vendor MTI Wireless Model MT-262024 Frequency Range (MHz) 902-928 MHz Circular Gain (dBiC) 7,5 dBiC Linear Gain (dBi) 6.0 dBi Polarization Circular (RHCP) Type Patch...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 2 Introduction 2.1 About this guide This user guide provides detailed information about the readers and is divided into two large parts, Part 1 with information for the physical installation (mechanical) of the reader and Part 2 with information on the operation and operation of the reader, including programming and configuration.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 3 Introduction to equipment Edge-30R+ and Edge-30R-N+ readers are equipment with small and high-performance Radio Frequency Identification (UHF) RFID technology and high tag reading performance, with features and functionality useful for vehicular access control solutions that are described throughout this document. Below are the main features: •...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 4 Table of revisions 4.1 User guide table Month/ye Revision Description ar date • Update the information according to the Edge-30R+ Autoid and 02/2021 Edge-30R-N+ Autoid reader; • PcI change and information. •...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 • 03/2015 Creation of this document. 4.2 Readers firmware table Month/ye Revision Description ar date ● Fixed ERROR in the safe mode tag verification algorithm when two 3.4.7 04/2021 readers with different security codes stood side by side, close to each other, improper readings occurred.
Page 11
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 reader; ● Fixed memory consumption ERROR in the RS232 serial sending function. • Fixed ERROR in the IPV4LL generation algorithm in the events of disconnecting and connecting a network cable; •...
Page 12
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 ● Changed the feedback patterns of the status and link LEDs; ● Security Change, there is now a default password acura@autoid , it is no longer allowed to be without any password, changed the page hmtl Security, the password can have up to 16 chars;...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 4.3 Readers hardware table Month/ye Revision Description ar date ● Creation and launch of the Edge-30R reader. 03/2015 5 Installation notes and important warnings The maximum reading distance of passive tags per reader is up to 6m for the Edge-30R+, 4m for the Edge-30R-N+.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 6.2 General reader characteristics Transponder Protocols Protocole ISO 18000-6C (Gen2) Interface RF Edge-30R+: from 0 to 30dBm with 0.5dBm increment RF output power Edge-30R-N+: from 0 to 27dBm with an increment of 0.5dBm Regulation ANATEL (BR) 902 - 907 MHz e 915 - 928 MHz Mode...
Page 17
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Data / Control Interface (continued) 1x Opto-isolated Digital Input: 1KV RMS insulation Supports Dry Contact, NPN (Sinking) and PNP circuit (Sourcing). Minimum pulse width: 100ms High Level (3.0 to 24.0VCC), Low Level (0 to 2.0VCC) GPIO 1x Digital output opto-insulated by relin: High Level 24VCC...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 6.3 Hardware - PCI interface The PCI Interface should be used in conjunction with the Edge-30R+ Autoid and Edge-30R-N+ Autoid readers with the function of facilitating the installation of the readers. It has RJ45 type connector and terminals for a quick and easy connection between the readers and the client controller.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 6.4 General features of pci interface Data / Control Interface Reader Communication: RJ45 connector Communication/Digital Input/Digital Connectors Output Terminal type Removable terminal for cables/wires 12- 24 AWG [WG/ABA, INPUT, RELAY] Physical Characteristics Degree of protection Internal use only...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7 Mechanical installation 7.1 Reader attachment support Readers together with the fixing bracket can be fixed on poles with a diameter variation from 1" to 1.75" or 1.75" to 3", can also be fixed on flat surfaces such as walls. 7.1.1 Fixing bracket items Item 1 - Qt 1 Item 2 - Qt 4...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.1.4 Fixing the bracket arm at the base of the pole/wall Readers can be mounted with the cable facing the top side or on the sides, as it is easier for installation, as the integrated antenna has circular polarization, the position NOTE: in which the reader is installed relative to the output of its cable will not influence the performance of reading tags.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.2 Positioning of readers The measurements and illustrations described in this section are recommendations for the best performance of reading the passive tag in the vehicle. It is important to follow the reader's maximum installation height recommendations so that the NOTE: effective distance between the reader and the installed tag does not exceed the...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.2.2 Track center Reader Max = 3m Physical barrier Gate sensor Vehicle sensor The angle of the reader depends on the height of installation, the face of the antenna of the reader should be pointed to where the tag in the vehicle will be at the ideal reading distance of 3m between the reader and tag.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.3 Reading problems When there are adjacent lanes near each other, tag readings may occur on unwanted tracks or locations near the reader's installation point. Below are some examples of multi-lane installations. To minimize the occurrence of unwanted reads as much as possible, some actions can be performed: Filter of unwanted side/adjacent readings.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.4 Food and Communication To facilitate the installation of the reader, the power is made from a POE Injector via RJ45 cable, not requiring the PCI to be energized. If wiegand/abatrack communication is used, or the use of the input and logical output, it is necessary to use the PCI, which in turn, this communication is made by an RJ45 cable connected directly to the Interface Card of the reader.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.2 Electrical connections - Reader The figure below describes the reader's connection to the POE Injector. Reader POE Input Injector (Optional) No scale The table below describes the pins and colors of the RJ45 cable that will be used to connect the POE injector with the reader.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.3 Electrical connections - PCI The figure below describes the reader's connection to the PCI. Interface Signal No scale The table below describes the pins and colors of the RJ45 cable that will be used to connect the PCI Interface with the reader.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.4 Electrical connections - Ethernet LAN The figure below describes the connection of the reader's POE injector to the local Ethernet network of the client. Switch/Router Ethernet IN PoE Injector scale (Optional) The table below describes the pins and colors of the network cable that will be used to connect the...
Page 35
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Brown (MR/MR CL) NOTA: A standard T568A or T568B network cable can be used to connect the Injector to the. The figure below describes the electrical connections of the Wiegand/Abatrack communication interface, which can be done with a customer's computer or with the client's controller board.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 To avoid noise and external interference that may hinder communication between the reader and the controller/PC, avoid passing NOTICE: the Wiegand communication cable/flap near sources, lamp reactors, electrical power cables, or other electromagnetic noise sources. 8.6 Electrical connections - Digital input (Sensor) The digital input of the reader has the following electrical characteristics: ●...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 For digital input, use the "ISO_GND" pin for sensors with Dry Contact NOTICE: output and use the "ISO_COM" pin for sensors with wet contact output in any polarity. 8.7 Electrical connections - Relé Built into the PCI, the reader itself can send a digital signal through the handover.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.8 Reader visual indicators The reader has an operating status LED on the antenna. 8.8.1 STATUS visual indicator Blinks once fast (flashs) loop Indicates that the reader is in Continuous Read Mode. Lit during flash Indicates that a Tag Read occurred while the reader was in read mode.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.9 POE Injector Visual Indicators The injector has two status LEDs for operation. Below, here is a table stating what each behavior of the LEDs located on the injector means Yellow LED lit continuously and green LED off Indicates that the injector is being powered but is not connected to the reader...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 9 Modes of operation of the reader 9.1 Continuous reading mode In this read mode, the reader performs read operations continuously, in other words, the reader is placed in a loop where it first performs the inventory operation and then sends the obtained results. This way, whenever a tag enters the reader's reading field, it will be read and its data sent through the communication ports.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 9.2 Trigger read mode In this reading mode, the reader performs read operations only when it receives a signal from a connected sensor in its digital input, which can be accessed by the "SENSOR INPUT" connector of the PCI Interface.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10 Configuring the Readear 10.1 Reader IP address Readers (firmware 2.1.6 or above) with factory settings automatically generates their IP address using the default Range of Local Link Address IPV4 169.254.0.0/16. Readers use the following logic for generating their IP when they have factory settings: IP = 169,254.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 After the user has set up a static IP, the reader no longer generates the IPV4LL, only NOTE: if a Hard reset is performed. 10.2 Configuring the reader via web browser The reader settings are made by accessing the reader through LAN or WAN networks, placing its IP address in an internet browser (Web Browser).
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Only one user is able to connect to the reader configuration page. Login to the setup page expires after 3 (three) minutes. Thus, if another user wants to connect, they NOTE: must wait for the first user to log out or pass the expiration time without any update on the page.
Page 46
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 RFID Hardware Hardware version of the RF module of the reader. AutoID Version Firmware version of the reader's internal controller. Status parameters (Continued): Parameter Description Physical address of the Ethernet interface, consisting of 6 bytes, is MAC Address shown in decimal and hexadecimal format.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.2.2 Security Settings After login, click the Security option. Change the settings. Click Apply to make the changes. If the Restart message is shown, click Restart. Security page parameters: Parameter Description Alphanumeric characters of a maximum of six digits that can be written to the reader to form the password that will give access to the settings...
Page 48
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Security page parameters (Continued): Parameter Description Type of reading algorithm that the reader will run. Normal: The reader does not check any kind of security in reading the tags, it reads any standard ISO-18000-6C tag (UHF Gen2) in its reading field and reports on its communication interfaces.
Page 50
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Parameter Description Defines the behavior of the reader on the network, and can act as Ethernet Mode server or client. Factory configuration: Server Fixed IP address of the reader, this version of the reader does not support DHCP.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.2.4 Setting Up Reading After login, click Read. Change the parameters. Click Apply to save the changes. If you see the message prompting you to restart the reader, click Restart. Reading Parameters: Parâmetro Descrição...
Page 52
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Read parameters (continued): Parameter Description Power in centidBm (dBm / 100) referring to tag reading. The read power can be adjusted to change the read region of tags at the Reading power installation location.
Page 54
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Communication Parameters: Parameter Description Reading results are made available through the Wiegand or Abatrack communication interfaces, and simultaneously through tcp/IP Ethernet interfaces. Type You can use the two signal lines (W0/CLK) and (W1/DATA) as digital outputs, communication selected None(GPO), thereby disabling Wiegand and Abatrack communications.
Page 55
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Communication parameters (Continued): Parameter Description Keyword Description Size [characters] TEMP Temperature in °C of internal RF module. TYPE Tag type read, 'S' for Safe and 'N' for Normal ALIVE Reader uptime in seconds 1 a 10 <CR>...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Note: Other characters or words that do not match the words keys will be mirrored in the keepalive string that the reader transmits at each keepalive time interval. Factory configuration: <CR><LF> Communication parameters (Continuation): Parameter Description...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 IO parameters: Parameter Description Lógica invertida do Reverses the trigger signal trigger ing logic (the NF contact of the lens can be sinal de entrada used for example). trigger Factory configuration: not selected (normal logic). IO (Relé) parameters: Description...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Parameter Description If an SNTP server cannot be used for clock timing Adjust date and there is the possibility of manual adjustment of the watch. time Note: When loading the page, the date and time fields are updated manually with the data from the reader's internal clock.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Messages and replies must contain the prefix "$" (dollar sign followed by space) and the carriage return terminator <CR> The "SET" and "GET" functions should be just after the prefix and before the command separated by a space character.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.3.4 Example of use Terminal emulator software, such as Putty or TeraTerm, should be used when a user wants to check or change reader parameters via ASCII messages. 10.3.5 Checking the status of the reader Command Function Description...
Page 61
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Checks the connection status of the data communication port. Example: Direction Description Host → $ GET STATCONN1<CR> Host sends the message. STATCONN1 Reader STATCONN2 Host ← Reader Disconnected port. $ DISCONNECTED<CR> $ GET STATCONN2<CR>...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Verifica o status da conexão da porta de comunicação de dados. Example: Direction Description Host → Reader Host sends the message. $ GET TMALIVE<CR> TMALIVE $ 80577<CR> Host ← Reader 80577 seconds without rebooting.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Exemplo: Direction Description Host → Reader Host sends message to check which $ GET AUTOID<CR> Autoid System is running. Host ← Reader Reader replies that it is Autoid $ NORMAL<CR> Normal.
Page 64
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Example: Direction Description Host → Leitor $ GET DNS1ADDR<CR> Host sends the message to verify the address of the DNS server. Host ← Reader Reader responds with the $<CR> value of the address; in this case it is empty.
Page 65
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Host → $ SET SYSLGADDR=192..168.0.84<CR> Host sends the message to change the IP address of Reader the Syslog server. $ ERROR<CR> Host ← Reader Reader responds with error because the address format was incorrect.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Checks the physical address of the reader's Ethernet interface in two formats, decimal "MACDEC" and hexadecimal "MACHEX". Example: Direction Description Host → Host sends the message to read the $ GET MACDEC<CR> MAC in decimal.
Page 67
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Changes or checks the time, in seconds, of the read trigger. Values from 1 to 600s are allowed. Note: You do not need to reboot the reader. Note: Parameter used only when read mode is Trigger. Example: Direction Description...
Page 68
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Changes or checks the filter value by signal level (RSSI). Values from 20 to 99 dbm are allowed, leaving the value empty disables the filter. Note: You do not need to reboot the reader. Example: Direction Description...
Page 69
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Host → Host sends the message to change the $ SET SNDOPT=DRIVER<CR> parameter. Reader Host ← Reader Reader responds with OK. $ OK<CR> Changes or verifies the id that will be sent when an associated vehicular tag is identified by the reader, and the driver tag associated with the car tag has not been identified.
Page 70
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Setting Reading (continued): Changes or checks the value of the mask that the Id must contain to be read. Values allowed hexadecimal characters of a maximum of 24 digits. Note: You do not need to reboot the reader. Note: Parameter used only when autoid system type is Normal.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.3.9 Configurando Comunicação Changes or verifies which communication interface the reader should use. Values [WIEGAND, WG, ABATRACK, ABA, GPO]. Note: None (GPO) to use w1/DATA and W0/CLK signals as digital outputs triggered via ASCII messages.
Page 72
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Configuring Communication (continued): Change or check the Keepalive String, maximum 15 characters, for more details see section 10.1. Note: You do not need to reboot the reader. STRKP SET/GET Example: Example: Direction Example:...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.3.10 Configuring GPIO Changes or checks the time in milliseconds when the reader's digital input signal must remain enabled for the read operation to fire in trigger mode. Values from 0 to 1000ms.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Host → $ SET OUTPUT0=~<CR> Host sends the message to reverse the logical state of the l.A. Reader Host ← Reader Reader responds with OK. $ OK<CR> Host → Host sends the message to trigger $ SET OUTPUT0=*<CR>...
Page 75
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Changes or checks the use of daylight-saving time on the reader's internal clock. Values [ON, OFF]. Note: You do not need to reboot the reader. Example: Direction Description DLSV SET/GET Host →...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 11 Data communication 11.1 TCP/IP connections to receive tag readings The Edge-30R(-N)+ Autoid reader has the behavior of a Server and is capable of providing up to 2 (two) simultaneous TCP/IP connections for communication of the tag read data, in addition to the Serial Interfaces RS232 and Wiegand/Abatrack, that is, up to two different software (processes) that are on the same Ethernet network of the reader, can connect to it to receive the tag reading results.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 11.2 TCP/IP connection, disconnection, and reconnection logic Readers have the behavior of a Server, that is, it accepts TCP/IP connections on the user-configured port. Below are some important points regarding the reader server behavior: •...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 11.3 Format of reading results via TCP/IP and RS232 The format in which data is sent via Ethernet can be configured using the Data String parameter that uses key words to combine the results of reading tags with other desirable characters in the final string that the reader must send.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Regras de formato da String de dados: 1. Somente pode haver duplicidade dos caracteres de controle <CR> <LF> <STX> <ETX>, as demais palavras chaves não podem ser duplicadas; 2. A String de dados deve conter ao menos uma das palavras chaves IDHEX, IDWG ou IDABA;...
Page 80
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Message Category Description BOOT Messages about the firmware boot of the reader. CLOCK Messages related to the internal clock process. Messages related to the DNS name resolution process of the SNTP and Syslog servers.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 12 Mensagens de Log do leitor - Syslog Collecting syslog messages from the reader is very important to make a diagnosis of how the reader is behaving in its operating environment. It is recommended to collect messages even if the reader is being used with Wiegand or Abatrack interface.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 13 Regional Regulations 13.1 Frequencies and operating region When booting the Edge-30R Autoid reader, the operating frequencies (Hop-Table) are configured according to the pre-established region in the reader firmware. For the Brazil, the configured frequencies are: ANATEL (Brazil) Edge-30R+ 902 to 907MHz and 915 to 928MHz ANATEL (Brazil) Edge-30R-N 915 to 928MHz...
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 15 Solutions to common problems 15.1 I do not know the IP of the Reader In this case there are two options. You can use device explorer software (for Windows) to find readers that are on the same LAN network.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 is properly made according to the Electrical Connections - Ethernet Network; Make sure that the two RJ45 connectors on the reader cable are connected to the PCI Interface in the correct order, connector "COMMAND READER" - black cable and connector "READER ETHERNET"...
Page 92
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 ACURA Global is the pioneer in the Radio Frequency Identification (RFID) market in Brazil and Latin America, and has successfully explored, since the late 1990s, its large-scale adoption in the most diverse sectors of the economy, from mining to from agriculture to food processing, from logistics to retail, from transport to the distribution chain, from access control to asset management.