DK2 AC20G User Manual

DK2 AC20G User Manual

Twin cylinder 2 hp 20-gallon oil-free silent air compressor
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

AC20G
TWIN CYLINDER 2 HP 20-GALLON OIL-FREE
SILENT AIR COMPRESSOR
USER MANUAL
DK2 USA WEST
DK2 CORPORATE HEAD OFFICE
DK2 USA EAST
3311 MEADE AVENUE STE
5330 MAINWAY
3750 SOUTH AVENUE
E DOCK 13, LAS VEGAS, NEVADA
BURLINGTON, ONTARIO
NORTH UNIT, TOLEDO, OHIO
89102 USA
L7L6A4 CANADA
43615 USA
CUSTOMER SERVICE 1 (888) 277-6960 | WWW.DK2.COM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AC20G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DK2 AC20G

  • Page 1 DK2 CORPORATE HEAD OFFICE DK2 USA EAST 3311 MEADE AVENUE STE 5330 MAINWAY 3750 SOUTH AVENUE E DOCK 13, LAS VEGAS, NEVADA BURLINGTON, ONTARIO NORTH UNIT, TOLEDO, OHIO 89102 USA L7L6A4 CANADA 43615 USA CUSTOMER SERVICE 1 (888) 277-6960 | WWW.DK2.COM...
  • Page 2: Warranty

    DK2 will repair, replace, or supply any covered defective part at our option. DK2 is 1-year parts only warranty no labor. Upon expiry of one (1) year, DK2 will have no further liability related to the product. DK2 does not authorize any party, including its authorized distributors or dealers, to offer any other warranty on behalf of DK2.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS WARRANTY ................2 TABLE OF CONTENTS .
  • Page 4: Technical Specifications

    50cm (L) x 44cm (W) x 112cm (H) WEIGHT 106.9lb (48.5kg) 18.7” (L) x 17.9” (W) x 45.3” (H) SHIPPING DIMENSIONS 47.5cm (L) x 45.5cm (W) x 115cm (H) SHIPPING WEIGHT 116.8lb (53kg) WARRANTY 1-year limited 4 | AC20G(H) man.
  • Page 5: Section I • Safety

    SECTION I • SAFETY...
  • Page 6: Safety Conventions

    These compressors power spray guns, impact wrenches and other tools. These units operate without oil. Compressed air from this unit will contain moisture. Install a water filter or air dryer if application requires dry air. 6 | AC20G(H) man.
  • Page 7: Safety Decals

    SAFETY DECALS Make sure all safety warning decals are attached and in readable condition. POWER SWITCH AIR COMPRESSOR COMPRESSEUR À AIR Model/Modèle : AC20G INTERRUPTEUR Voltage & Current / Tension et courrant 120V ~ 60Hz 14.5 A Power / Puissance...
  • Page 8: Unpacking

    Grade D breathing as described in Compressed Gas Association Commodity Specification G7.1-1966, OSHA 29 CFR 1910.134, and/or Canadian Standards Associations (CSA). 8 | AC20G(H) man.
  • Page 9 WARNING! Motors, electrical equipment and controls can cause electrical arcs that will ignite a flammable gas or vapor. Never operate or repair in or near a flammable gas or vapor. Never store flammable liquids or gases in the vicinity of the compressor. CAUTION! RISK OF BURNS: Compressor parts may be hot even if the unit is stopped.
  • Page 10 The air compressor should also have the proper three prong grounding plug, correct voltage, and adequate fuse protection. 10 | AC20G(H) man.
  • Page 11: Section Ii • Installation

    SECTION II • INSTALLATION...
  • Page 12: Location

    2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire. 12 | AC20G(H) man.
  • Page 13: Extension Cords

    WARNING! Never connect green (or green and yellow) wire to a live terminal. 3. Check with a qualified electrician or serviceman if grounding instructions air not completely understood, or if in doubt as to whether product is properly grounded. Do not modify plug provided; if it will not fit outlet, have proper outlet installed by a qualified electrician.
  • Page 14: Section Iii • Operation

    SECTION III • OPERATION...
  • Page 15: Components

    COMPONENTS DRAIN VALVE: Used to drain condensation from the air tank. Located at bottom of tank. MOTOR THERMAL OVERLOAD: The motor has an automatic thermal overload protector. If the motor overheats, this protector will shut off the motor. The motor must be allowed 30 minutes to cool before restarting.
  • Page 16: Break-In Procedure

    4. Turn fully counter-clockwise to shut off flow of air completely then push knob down. FIGURE 3: PRESSURE REGULATING VALVE / SOUPAPE DE RÉGULATION DE PRESSION TANK PRESSURE GAUGE This gauge shows pressure in tank indicating compressor is building pressure properly. 16 | AC20G(H) man.
  • Page 17: Thermal Overload Protector

    WARNING! Disconnect power source then release all pressure from the system before attempting to install, service, relocate or perform any maintenance. Check compressor often for any visible problems and follow maintenance procedures each time compressor is used. 1. Pull ring on safety valve and allow it to snap back to normal position. WARNING! Safety valve must be replaced if it cannot be actuated or it leaks air after ring is released.
  • Page 18: Section Iv • Maintenance

    SECTION IV • MAINTENANCE...
  • Page 19: Daily Start-Up Procedure

    DAILY START-UP PROCEDURE 1. Set the Auto-On/Off lever to the Off position. 2. Check the air compressor visually for any damage or obstruction. 3. Close the drain valve. 4. Connect the air hose to the quick connect socket on the regulator assembly by inserting the quick connect plug on the air hose into the quick connect socket.
  • Page 20: Maintenance Procedure Schedule

    The modifications will depend upon the hours of operation and the working environment. Air compressors used in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks. 20 | AC20G(H) man.
  • Page 21: Troubleshooting

    TROUBLESHOOTING SYMPTOM CORRECTIVE ACTION Air leaks at the A defective check valve results in a constant air leak at the pressure release valve when check valve or at the there is pressure in the tank and the compressor is shut off. Drain the tank, then remove pressure relief valve and clean or replace the check valve.
  • Page 22: Section V • Parts & Schematics

    SECTION V • PARTS & SCHEMATICS...
  • Page 23: Parts List

    PARTS LIST PART # NO. SPECIFICATION QTY. PART # NO. SPECIFICATION QTY. AC20G01H22 01 Screw M10 x 45 AC20G37H22 37 Stator AC20G02H22 02 Spring washer M10 AC20G38H22 38 Rotor AC20G03H22 03 Bolt M5 x 20 AC20G39H22 39 Motor buckle AC20G04H22 04 Spring washer M5 AC20G40H22 40 Screw M5 x 22...
  • Page 24 AC20G80H22 80 Capacitor cover AC20G91H22 91 Screw M8 x 30 AC20G81H22 81 Screw M4 x 8 AC20G92H22 92 8" wheel AC20G82H22 82 Nut M8 AC20G93H22 93 Nut M8 AC20G83H22 83 Bolt M8 x 17 AC20G94H22 94 Axle 24 | AC20G(H) man.
  • Page 25: Schematics

    SCHEMATICS v.220629 | 25...
  • Page 26 SIÈGE SOCIAL CORPORATIF DK2 DK2 USA EST 3311 MEADE AVENUE STE 5330 MAINWAY 3750 AVENUE SUD QUAI E 13, LAS VEGAS, NEVADA BURLINGTON, ONTARIO UNITÉ NORD, TOLEDO, OHIO 89102 ÉTATS-UNIS L7L6A4 CANADA 43615 ÉTATS-UNIS SERVICE À LA CLIENTÈLE 1 (888) 277-6960 | WWW.DK2.COM...
  • Page 27: Garantie

    émises. Aucun retour de produit ne sera accepté sous garantie à moins d’être accompagné d’un numéro RGA émis par DK2. DOMMAGE DU AU TRANSPORT Les dommages causés à...
  • Page 28 SCHÉMAS ................51 28 | AC20G(H) man.
  • Page 29: Spécifications Techniques

    SPÉCIFICATIONS TECHNIQUES TAILLE DU RÉSERVOIR Compresseur vertical ASME de 20 gallons PUISSANCE 1491.4W / 2 CV TENSION 120V CA FRÉQUENCE 60Hz VITESSE 1 700 tr/min DÉPLACEMENT @ 90PSI 4.5CFM DÉPLACEMENT @ 40PSI 5.5CFM INTERRUPTEUR AUTOMATIQUE DE PRESSION D’AIR 150PSI REDÉMARRAGE DE LA PRESSION D’AIR 120PSI AMPÉRAGE @ MAX...
  • Page 30: Section I • Sécurité

    SECTION I • SÉCURITÉ...
  • Page 31: Conventions De Sécurité

    CONVENTIONS DE SÉCURITÉ Ce manuel contient des informations qu’il est très important de connaître et de comprendre. Ces informations sont prévues pour votre sécurité et pour éviter les problèmes d’équipement. Pour faciliter la reconnaissance de ces informations, respectez les symboles suivants. DANGER ! Cela indique une situation dangereuse qui, si elle n’est pas évitée, entraînera la mort ou blessure grave.
  • Page 32: Autocollants De Sécurité

    Ne retirez pas le couvercle l’humidité du Ce produit contient des produits réservoir pour chimiques reconnus par l’État de prévenir la corrosion. Californie pour causer des cancers et des anomalies congénitales ou d’autre ACTDL 1709 dommages à la réproduction. 32 | AC20G(H) man.
  • Page 33: Déballage

    DÉBALLAGE Après avoir déballé l’appareil, inspectez-le soigneusement pour tout dommage qui aurait pu se produire pendant le transport. Assurez-vous de serrer les raccords, les boulons, etc., avant de mettre l’appareil en service. AVERTISSEMENT ! N’utilisez pas ce produit s’il fut endommagé pendant l’expédition, la manutention ou son utilisation.
  • Page 34 10. Pour réduire les risques d’incendie, gardez l’extérieur du moteur exempt d’huile, de solvant ou de graisse. AVERTISSEMENT ! Ne jamais retirer ou tenter de régler la soupape de sécurité. Gardez la soupape de sécurité exempte de peinture et autres accumulations. 34 | AC20G(H) man.
  • Page 35 DANGER ! RISQUE D’ÉCLATEMENT : Toujours vidanger le réservoir du compresseur quotidiennement ou après chaque utilisation. Si le réservoir présente une fuite, remplacez le compresseur. N’utilisez jamais le compresseur après qu’une fuite a été trouvée ou essayé d’apporter des modifications au réservoir. Ne jamais modifier les réglages d’usine du compresseur qui contrôlent la pression du réservoir ou tout autre fonction.
  • Page 36 électricien et doit se conformer à tous les codes électriques nationaux et locaux. Le compresseur devrait également avoir la prise de terre à trois broches appropriées, la tension correcte, et une protection par fusible adéquate. 36 | AC20G(H) man.
  • Page 37: Section Ii • Installation

    SECTION II • INSTALLATION...
  • Page 38: Emplacement

    à tous les codes et ordonnances locales. DANGER ! Une mauvaise utilisation de la prise de mise à la terre peut entraîner un risque possible de choc électrique. DANGER ! N’utilisez pas d’adaptateur de mise à la terre avec ce produit. 38 | AC20G(H) man.
  • Page 39: Rallonges Électriques

    2. Si la réparation ou le remplacement du cordon ou de la prise est nécessaire, ne connectez pas le fil de mise à la terre à l’une ou l’autre des bornes à lame plate. Le fil avec isolation ayant une surface externe qui est vert (avec ou sans bandes jaunes) est le fil de mise à...
  • Page 40: Section Iii • Fonctionnement

    SECTION III • FONCTIONNEMENT...
  • Page 41: Composantes

    COMPOSANTES ROBINET DE VIDANGE : Utilisée pour évacuer la condensation du réservoir d’air. Situé au bas du réservoir. PROTECTEUR DE SURCHARGE THERMIQUE DU MOTEUR : Le moteur est doté d’une protection automatique contre les surcharges thermiques. Si le moteur surchauffe, ce protecteur éteindra le moteur.
  • Page 42: Procédure De Rodage

    4. Tourner complètement dans sens FIGURE 3: PRESSURE REGULATING VALVE / SOUPAPE DE RÉGULATION DE PRESSION antihoraire pour couper le débit d’air complètement puis poussez le bouton vers le bas. 42 | AC20G(H) man.
  • Page 43: Manomètre De Pression De Réservoir

    MANOMÈTRE DE PRESSION DE RÉSERVOIR Cette jauge indique la pression dans le réservoir indiquant que le compresseur accumule correctement la pression. AVERTISSEMENT! Débranchez la source d’alimentation, puis relâchez toute la pression du système avant d’essayer d’installer, de réparer, de déplacer ou d’effectuer tout entretien. Vérifiez souvent le compresseur pour tout problème visible et suivre les procédures d’entretien chaque fois que le compresseur est utilisé.
  • Page 44: Section Iv • Entretien

    SECTION IV • ENTRETIEN...
  • Page 45: Procédure De Démarrage Quotidien

    PROCÉDURE DE DÉMARRAGE QUOTIDIEN 1. Réglez le levier Auto-On/Off sur la position Off. 2. Vérifiez visuellement le compresseur d’air pour tout dommage ou obstruction. 3. Fermez le robinet de vidange. 4. Connectez le tuyau d’air à la prise de connexion rapide sur l’ensemble du régulateur en insérant la prise de connexion rapide du tuyau d’air dans l’embout de connexion rapide.
  • Page 46: Entreposage

    à la condition dans laquelle votre compresseur est utilisé. Les modifications dépendront des heures d’opération et de l’environnement de travail. Un compresseur à air utilisé dans un environnement extrêmement sale et/ou hostile nécessitera une plus grande fréquence de tous les contrôles d’entretien. 46 | AC20G(H) man.
  • Page 47: Dépannage

    DÉPANNAGE SYMPTÔME MESURE CORRECTIVE Des fuites d’air au Un clapet anti-retour défectueux entraîne une fuite d’air constante au niveau de la clapet anti-retour soupape de surpression lorsque il y a de la pression dans le réservoir et le compresseur ou à la soupape de est arrêté.
  • Page 48: Section V • Pièces Et Schémas

    SECTION V • PIÈCES ET SCHÉMAS...
  • Page 49: Liste Des Pieces

    LISTE DES PIECES PIÈCE # NO. SPÉCIFICATION QTÉ. PIÈCE # SPÉCIFICATION QTÉ. AC20G01H22 Vis M10 x 45 AC20G37H22 Stator AC20G02H22 Rondelle de blocage M10 AC20G38H22 Rotor AC20G03H22 Boulon M5 x 20 AC20G39H22 Boucle AC20G04H22 Rondelle de blocage M5 AC20G40H22 Vis M5 x 22 AC20G05H22 Culasse 1 AC20G41H22...
  • Page 50 Tuyau Flexible de pression 1 AC20G90H22 Rondelle Ø8 Couvercle du AC20G80H22 AC20G91H22 Vis M8 x 30 condensateur AC20G81H22 Vis M4 x 8 AC20G92H22 Roue 8” AC20G82H22 Écrou M8 AC20G93H22 Écrou M8 AC20G83H22 Boulon M8 x 17 AC20G94H22 Essieu 50 | AC20G(H) man.
  • Page 51: Schémas

    SCHÉMAS v.220629 | 51...

Table of Contents