Advertisement

Quick Links

CCTV TESTER
User Manual
ECT-CCTV071
(V01.00)
For more information call:
NSW: ARTARMON Unit 3, 6-8 Mclachlan Ave, Ph: 02-9438-3266 Fax: 02-9438-2924
KINGSGROVE Unit E3, 15 Forrester Rd, Ph: 02-9150-6033 Fax: 02-9150-6044
BLACKTOWN Unit 1, 36 Binney Rd Ph: 02-8811-5155 Fax: 02-9831-2139
WA: BELMONT Unit 2, 28 Belmont Avenue, Ph: 08-9478-6411 Fax: 08-9478-6422
QLD: NERANG Unit 13, 12-20 Lawrence Drive, Ph: 07-5596-5533 Fax: 07-5596-5194
Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECT-CCTV071 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ecraft ECT-CCTV071

  • Page 1 CCTV TESTER User Manual ECT-CCTV071 (V01.00) For more information call: NSW: ARTARMON Unit 3, 6-8 Mclachlan Ave, Ph: 02-9438-3266 Fax: 02-9438-2924 KINGSGROVE Unit E3, 15 Forrester Rd, Ph: 02-9150-6033 Fax: 02-9150-6044 BLACKTOWN Unit 1, 36 Binney Rd Ph: 02-8811-5155 Fax: 02-9831-2139...
  • Page 2 Thank you for purchasing the IP camera tester. Please read the manual before using the IP camera tester and use properly. For using the IP camera tester safely, please first read the「Safety Information」carefully in the manual. The manual should be kept well in case of reference. Keep the S/N label for after-sale service within warranty period.
  • Page 3: Table Of Contents

    Content 1 .Safety information ..........................1 2. IP Camera Tester Introduction ......................2 2.1 General ............................2 2.2 Packing list ..........................3 2.3 Function interface ........................4 3. Operation ............................. 7 3.1 Installing the Battery ........................7 3.2 Instrument connection ........................ 8 3.2.1 IP camera connection ......................
  • Page 4 3.3.13 AutoHD ( *Optional ) ....................44 3.3.14 HD Coaxial & Analog level test ( *Optional ) ............. 44 3.3.15 SDI Camera Test ( *Optional ) ................. 46 3.3.16 CVI camera test ( *Optional ) ................... 47 3.3.17 TVI camera test ( *Optional ) ................... 54 3.3.18 AHD camera test ( *Optional ) .................
  • Page 5 3.3.35 Media Player ....................... 89 3.3.36 RTSP Player ........................ 90 3.3.37 Hik test tool ......................... 91 3.3.38 Dahua test tool ......................95 3.3.39 Update ........................100 3.3.40 Office ........................101 3.3.41 LED Flashlight ......................102 3.3.42 Browser ........................102 3.3.43 Notepad ........................103 3.3.44 System Setting......................
  • Page 6: Safety Information

    1 .Safety information ◆ The tester is intended to use in compliance with the local rules of the electrical usage and avoid to apply at the places which are inapplicable for the use of electrics such as hospital, gas station etc. ◆...
  • Page 7: Ip Camera Tester Introduction

    ◆Never connect the meter with any voltage source while the function switch is in the current, resistance, capacitance, diode, continuity, otherwise it will damage the meter. ◆Never perform capacitance measurements unless the capacitor to be measured has been discharged fully. ◆Never measure any of resistance, capacitance, diode or continuity measurements on live circuits.
  • Page 8: Packing List

    2.2 Packing list 1). Tester 2). Adaptor DC12V 2A 3). Network cable tester 4). Polymer lithium ion battery (7.6V DC 7500mAh) 5). BNC cable 6). RS485 cable 7). SC, ST connector(Only for optical power meter) 8). Multi-meter test leads one pair of red and black (only for the Multi-meter models) 9). Output Power cable 10).
  • Page 9: Function Interface

    2.3 Function interface Press more than 2 seconds, turn on or off the device, short press to turn on or off the menu display Menu key, press it to call short- menu. 4xzoom the image displays. Far focus: Focus the image faraway Near focus: Focus the image nearby TELE: zoom in the image WIDE: zoom out the image...
  • Page 10 Upward, set function or add parameter. Tilt the PTZ upward Rightward, select the parameter whose value will be changed. Add the value of the parameter. Pan the PTZ right Downward, set function or reduce the value of the parameter. Tilt the PTZ downward Leftward, select the parameter whose value will be changed Confirm key,(Long press it to capture screen interface)
  • Page 11 Top interface Bottom interface Visible red laser source emits Interface (Optional) DC12V3A power output, for provisional DC power supply HDMI IN (Optional ) CVBS IN/AHD /TVI/CVI Coaxial interface /(BNC interface)(AHD /TVI/CVI (Optional) ) Video signal output(BNC interface)/ cable tracer interface Optical power meter interface (Optional) LED lamp RS485 Interface: RS485communication for the PTZ...
  • Page 12: Operation

    HDMI output interface Micro SD card moveable,(comes with 8GB, supports up to 32GB) UTP cable port: UTP cable tester port/ Cable tracer port PSE power sourcing equipment. Tests PoE voltage/LAN test port PoE power supply output or LAN test port (Using test PoE or non-PoE IP camera) Microphone USB 5V 2A power output, transmit data DC 12V 2A charging interface.
  • Page 13: Instrument Connection

    Notice: Press the key several seconds to restore the default settings when the instrument works abnormally. Multi-meter: the red and black multi-meter pen must insert the corresponding port. Warnings: Instrument communication port is not permitted access circuit voltage over 6V, otherwise damage the tester.
  • Page 14: Analog Camera Connection

    2) If use the tester's menu to turn off the tester's PoE power supply, the PoE switch and the power sourcing equipment are allowed to connect to the tester's PSE port, and the PoE power will be supplied to the IP camera by the tester's LAN port. On this condition, the tester cannot receive data from IP camera, but the computer connected to the PoE switch can receive the data via the the tester.
  • Page 15: Hd Coaxial Camera Connection

    3.2.3 HD Coaxial camera connection * SDI, CVI, TVI, AHD camera are classified as HD coaxial cameras. Hereby the following instruction of how to connect SDI camera to the tester is also applied to CVI, TVI, and AHD camera. 1) Connect the SDI camera's video output to the IP tester's "SDI IN" interface, the image will display on the tester.
  • Page 16: Hdmi Output

    3.2.5 HDMI output The built in HDMI output port can output live video from an analog or IP camera, recorded files, media files and images to HDTV monitors. Connect an HDMI cable from the IP tester to an HDTV monitor at any time.
  • Page 17: Short Cut-Menu

    network parameters. Settings: Enter settings interface. IP: Enter IP Settings interface. POE power output: Turn on or off the tester "PoE power" app. 3.3.2 Short cut-menu You can call shortcut –menu by press tester's "menu" key, you can self- define shortcut -menu. Press the key , you can turn on it, and switch functions, then press to enter app, tap other...
  • Page 18: Screen Capture

    3.3.3 Screen capture Long press the key "enter", can capture screen interface and save it in any time. You can go file management to view "file Explorer –sdcard- Pictures—Screenshots". 3.3.4 Link monitor Tap icon "Link Monitoring" at left corner on the screen, to enter. It can detect instrument port rate 10/100/1000M, signal quality detection, upload and download speed, etc.
  • Page 19 When using a four-core cable to connect to a Gigabit device, would prompt "the link limited". Advanced link monitor It is for monitoring CVBS loop, Ethernet statistics, error frame statistics, frame length etc Page.14. Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426...
  • Page 20: Testerplay

    3.3.5 TesterPlay Mobile screen projection (Only for android version) The meter creates WIFI hotspot, connect mobile phone to the tester's WIFI hotspot, or the tester and mobile phone connect the same Wi-fi network. Download and install Remote control app to mobile phone, Tap icon "...
  • Page 21: Ip Discovery

    IP discovery 3.3.6 Press IP discovery , tester auto-scan the whole network segment IP, as well as auto-modify the tester' s IP to the same network segment with the scanned camera's IP. Local IP: Tester's IP address, Tester can auto-modify the tester's IP to the same network segment with the scanned camera's IP Page.16.
  • Page 22: Ipc Test Pro

    Discovery IP: Connected tester equipment's IP address. If the camera connected to the tester directly, tester will display the camera's IP address, if tester connects to Local Area Network, it displays the current IP address. Temp IIP: After searching IP address, the modified tester's IP address will not be saved, if you do not select "Temp IP"...
  • Page 23: Rapid Onvif Test

    Application: Support multi-segment IP address scan, can visual display camera manufacturer, click IP address to play the image. Connect IP camera, can supply the power to PoE camera. Real-time display network port connection status. By one key to connect camera test tool, browser can login and configure camera. Batch activate Hikvision and Dahua cameras.
  • Page 24 display camera image. Click the button "Refresh", tester will scan the ONVIF camera again. Click the newly displayed ONVIF camera on the "Device List". The tester will show the IP camera's relative information and settings. Activate HIKVISION Camera: When connected inactivated HIKVISION Camera, tester can auto recognized, and prompt "The camera have not been activated, activated now?", click "OK"...
  • Page 25 Cross network scan: After open this function, enter "Setting - IP Settings - Advanced" to add other network segments IP, Rapid ONVIF function can across network segments to scan camera's IP. Auto Login: After open this function, tester can auto login camera and display camera image. (The login password is the same with last time, the first time using password is the default password "admin") Video transmission protocol: UTP and TCP protocol.
  • Page 26 ONVIF PTZ control: Tap the image in the direction you want the PTZ camera to move. Tap the left side of the image to move left, right to go right, up to go up and down to go down. Compatible IP PTZ cameras will rotate accordingly.
  • Page 27 Image setting: Click "Imaging Set" to adjust image brightness, saturation, contrast, sharpness and backlight compensation mode. Profiles: Click "profiles", can view video streaming current configuration files, as well as switch between Major stream and minor stream. Preview pictures: Quickly preview and zoom in or out pictures, automatically and manual refresh. Identification: Click "Identification"...
  • Page 28 Time set: Click "Time set", Select "Manual set" to set up the time of camera. Maintenance: For camera software reset or restore to factory settings. User Set: Modify camera user name, password etc parameters. Network setting: Click "Network Set" to change the IP address. Some cameras cannot support change IP address, so there is no change after saving.
  • Page 29 Zoom in image: Press the key to enter the zoom mode. Press it again to exit zoom mode.When the image is enlarged tap left, right, up or down on the image to move the whole image on the screen When the image is enlarged, if not operate on touch screen, it can operate by the keyboard, press the to zoon in, press the key to zoom out, press upward and downward key to move image.
  • Page 30 Image can only be enlarged on SD mode (The icon "ONVIF" is SD mode.) Select relative function on the bottom Toolbar to operate, "Snapshot" , "Record", "Photos", "Video playback", "Storage set", "PTZ control" etc. Snapshot: Click bottom "snapshot" to screenshot the image and store it to SD card. If select manual storage, appears dialog box "Input Name", user-defined the files name(by Chinese character, English letter or digit ) to save in SD card, if select "Auto- storage", the tester auto stores the files after snapshot.
  • Page 31 To rename or delete a photo, click and hold on the file until this screen appears: OSD Menu: Select OSD and popup the OSD menu. include time, channel name and other optional items. After channel selecting, you can edit the channel name, modify the display position, and switch the font size.
  • Page 32 Video files can play in the Video player on the main menu. Set preset position: Move the camera to preset position, enter the preset number on the Bottom right corner to complete position preset. Call the preset position: Select the preset number on the left, click "Call" to call preset. PTZ Speed set: Horizontal and Vertical Speed set.
  • Page 33 RTSP: Get RTSP address of the current camera Doc: Auto generate test reports document of camera, click "generate document". Click Preview to view the report document. Enter the camera test information, click "Generate Document" to complete the report. Page.28. Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426...
  • Page 34 Click "Doc" menu again, you can preview the report document. Icons description: The description of function icons on the bottom toolbar. Page.29. Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426...
  • Page 35: Non Onvif

    3.3.9 NON ONVIF Display image from the 4K H.265 camera by mainstream Click icon to enter IP camera test Note: Currently, the IPC Test App only supports some brands' specific IP cameras, these include specific models made by ACTI, AXIS, Dahua, Hikvision, Samsung, and many more. If the camera is not fully integrated, please use the ONVIF or RTSP apps.
  • Page 36 Stream code: When test camera via RTSP, you can select mainstream or sub stream to test (if camera's RTSP have not been start or without, it will tip "auto match fail, please switch to manually selecting". IP Camera's IP: Enter the IP camera's IP address manually or click "Search" to auto-scan for the IP camera's IP address.
  • Page 37: Hdmi In ( *Optional )

    IPC User Name: Enter IP camera's user name. IPC Password: Enter IP camera's login password. IPC Port: When you select the IP camera type, it will default the camera's port number and doesn't need to be changed. After all settings are completed, click "Enter" to view the live video. If IP address setting has error or IP camera is not connected..
  • Page 38 (1) Snapshot Click the icon "Snapshot", when the video in, to take a picture and save the current video frame in the SD card as JPEG file. If the unit is set to the manual mode an "Input Name" pop up box will appear and you can enter a title for the snapshot.
  • Page 39 icon again to stop recording and save the video file to the SD card. if select manual storage, before recording begins, appears dialog box "Input Name", user-defined the files name(by Chinese character, English letter or digit) to store in SD card, tester will hereby store the files in SD card after recording.
  • Page 40: Analog Camera Test

    (4) Recorded video playback Click the "Playback" icon to view your recorded videos. Tap on the video file image you want to watch. To rename or delete a video, click and hold on the file until this screen appears: Video files also can play in the main menu "Video Player". 3.3.11 Analog camera test Analog camera test and PTZ control, click icon to enter...
  • Page 41 Select relative function on the right side Toolbar to operate, functions including "Photos", "Snapshot" , "Record", "Playback", "PTZ", "Set". Click , or press to quit. Click the screen twice quickly, can be full zoom in on the touch screen. 1) PTZ controller parameter setting Select and click icon "PTZ", to enter PTZ setting: A.
  • Page 42 E. Pan speed: Set the pan speed of PTZ camera (0~63) F. Tilt speed: Set the tilt speed of PTZ camera (0~63) G. Set preset position (Set PS) Click and select "Set PS", set and save preset position number(1~128). H. Call the preset position (Go PS) Click and select "Set PS", set and save preset position number (1~128), click "sure"...
  • Page 43 3) 4 x zoom image display and Video out When image input, press to enter "zoom", press it again to quit. Using the touch screen to control PTZ camera movement: Tap left, right, upward or downward on the video image to move the PTZ camera in a desired direction. Stretch two fingers outward or inward on the touch screen to zoom the image in or out.
  • Page 44 clear. But for network digital video input, as it supports resolution up to 1280*960, the zoom in image is still very clear. This is very helpful for IP camera installation. 4) Snapshot Click the icon "Snapshot ", when the video in, to take a picture and save the current video frame in the SD card as JPEG file.
  • Page 45 (6)Photo Click the icon "photo" to enter, click the selected thumbnail photo to display it on the screen. Double-tap the image you want to view to make it full screen. Double-click again the photo to return. To rename or delete an image, click and hold on the file until this screen below appears. Click to close and return to PTZ controller.
  • Page 46 To rename or delete a video, click and hold on the file until this screen appears: Video files also can play in the main menu "Video Player". (8) Video level meter Click the icon to enter, the IP camera tester has adopted hardware high-speed sampling and processing technology, can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK, SYNC levels and COLOR BURST chroma level.
  • Page 47 Video signal level 140±15IRE NTSC Chroma level( COLOR BURST) 40±5IRE SYNC signal level 40±5IRE Video signal level 1000±200mV Chroma level( COLOR BURST) 300±35mV SYNC signal level 300±35mV Video signal PEAK to PEAK level: For NTSC format, the video signal level is 140±15IRE For PAL format, the video signal level is 1000±200mV If the level is too low, it will cause the image to lose quality and limit the distance it will travel over cable.
  • Page 48: Color-Bar Generator (Tv Out)

    For PAL format, the Chroma standard level is 280mV If the Chroma level is too low, the color will not be as deep, and some details of the image will become lighter. If the Chroma level is too high, there will be distortions on the image. If the coaxial cable is too long, it will reduce the chroma level.
  • Page 49: Autohd ( *Optional )

    A. When maintaining the dome camera, the tester sends out the color bar by its BNC output to the monitor at the monitoring center. If the monitor receive the color bar, it means the video transmit channel works normally. Meanwhile on the basis of the received color bar, the monitoring center can judge if transmission has loss or interference.
  • Page 50 Image display: Select the camera type, no need to select the resolution, click the camera icon, can browse the camera image directly. Level Meter Test: Need to select the camera type and resolution, click "test" to test the level Color bar generation: Click"CVBS", quickly enter color bar generation app Test Result:The percentage and signal grid of the level value.
  • Page 51: Sdi Camera Test ( *Optional )

    3.3.15 SDI Camera Test ( *Optional ) SDI camera test, Dome camera test and PTZ control, click icon to enter. Page.46. Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426...
  • Page 52: Cvi Camera Test ( *Optional )

    When tester receives SDI camera image, it will display the image data. Double-taps on the screen to make the image displayed full screen. The tester supports resolution as follows: 1280x720P 25Hz, 1280x720P 30Hz, 1280x720P 50Hz, 1280x720P 60Hz, 1920x1080P 25Hz 1920x1080P 30Hz, 1920x1080I 50Hz, 1920x1080I 60Hz, EX-SDI: 2560x1440P /25/30FPS, 3840x2160 20/30FPS.
  • Page 53 1920x1080P 30FPS/2560x1440P 25FPS/2560x1440P 30FPS/ 2592x1944P 20FPS / 2960x1920P 20FPS / 3840 x 2160P 12.5/15 FPS (1)PTZ control 1.1 Coaxial PTZ control Click the icon"PTZ"on the right toolbar to do the corresponding setting. "Port": select coaxial control Enter PTZ address to perform parameters setting Page.48.
  • Page 54 Operation instructions, please refer to "3.3.1 PTZ (1) Video monitor test" The PTZ address in the tester must be consistent with the dome camera or decoder, then the IPC tester can test. After setting the parameter, the tester can control the PTZ and lens. To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction, PTZ cameras will rotate accordingly.
  • Page 55 To control PTZ by key buttons  Press arrow keys to control to control the PTZ direction of rotation  Press the key to switch on or turn off the aperture.  Press the key to adjust the focus manually. ...
  • Page 56 1.2 RS485 control Operation instructions, please refer to "3.3.1 PTZ (1) PTZ control parameters setting". (2)Coaxial camera menu setting Tap icon "UTC", select "menu setting" to enter the dome camera menu. Page.51. Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426...
  • Page 57 Input calling dome camera menu address code, after finishing the parameter settings, you can press the or click the icon to call the dome camera menu. Press arrow keys to set Page.52. Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426...
  • Page 58 (3) Snapshot, record, photo viewer and video play back, please refer to "3.3.1 PTZ (1) Video monitor test". Tap "close menu" or press the key " " to close camera menu. (4) Save setting Click icon "Set" on the right toolbar to enter storage setting. Support auto-storage and manual storage.
  • Page 59: Tvi Camera Test ( *Optional )

    3.3.17 TVI camera test ( *Optional ) HD TVI camera, TVI dome camera test and PTZ control, Click icon to enter The tester supports resolution as follows: 1280x720P 25FPS / 1280x720P30FPS / 1280x720P 50FPS / 1280x720P 60FPS 1920x1080P 25FPS / 1920x1080P 30FPS / 1920x1080P 50FPS / 1920x1080P 60FPS //2048x1536P 18FPS/2048x1536P 25FPS/2048x1536P 30FPS /2560x1440P 15FPS/2560x1440P 25 FPS/2560x1440P 30FPS/2688x1520P 15FPS/2592x1944P 12.5FPS/2592x1944P 20FPS/3840 x 2160P 12.5/15 FPS Page.54.
  • Page 60 Coaxial camera menu settings Tap icon "UTC", select "menu setting" to enter the dome camera menu. Input calling dome camera menu address code, after finishing the parameter settings, you can press the or click the icon to call the dome camera menu. More operation instructions (such as PTZ control, coaxial camera menu setting, snapshot, recording and playback etc), please refer to "3.3.6 CVI camera test".
  • Page 61: Ahd Camera Test ( *Optional )

    3.3.18 AHD camera test ( *Optional ) AHD camera, AHD dome camera test and PTZ control, Click icon to enter The tester supports resolution as follows: 1280x720P 25,30FPS / 1920x1080P 25FPS / 1920x1080P 30FPS/2048x1536P 18,25FPS/2048x1536P 30FPS /2560x1440P 15 FPS/2560x1440P 25,30 FPS/2592x1944P 12.5,20FPS/3840 x 2160P 15FPS (1) Coaxial PTZ control UTC control: select "PTZ control or PTZ control-2"(AHD camera has two different order, if select "PTZ"...
  • Page 62: Net Tool Pro

    3.3.19 NET TOOL PRO NET TOOL PRO-Cable Test, Wireless Tool, Link Tool, Full Duplex Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, LLLDP. (1)IP address scan Connect the cable to the LAN port. Set your IP address search range by changing the Start and End IP addresses.
  • Page 63: 2)Ping Test

    (2)PING Test PING is the most conventional network debugging tool, it is used for testing if the connected IP camera or other network equipment's Ethernet port is working normally and the IP address is correct. Connect a network cable to the LAN port and click the icon to open the PING tool.
  • Page 64 When test, need a tester or a computer installed Network Test Software as the Server, the other tester sends packet test. The two testers must be in the same network segment. a). Start the server: Click "Start Server" button to use the tester as a Server. It will display its IP address at the top of the screen.
  • Page 65 Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software. Install network bandwidth testing software on a computer, as a test Client or Server, to do the mutual testing with the tester. If use computer as the server, the computer IP address is :192.168.0.39 Tester as Client, tester's IP address is:192.168.0.238.
  • Page 66: 4)Port Flashing

    Or use tester as a Server, computer as test Client(select Client, input tester's IP address to test) When use tester as Server, shows results: (4)Port Flashing Connect a network cable to the meter's "LAN" port, click the icon to open the Port Flashing app. Click "Start".
  • Page 67: 5)Dhcp Server

    Application: The tester will send special signals to make the connected LAN port flicker at special frequency, which will enable the installers to easily and quickly find the connected Ethernet cable. This function can prevent mistakenly insertion or disconnection non-corresponding cable to artificially interrupt network connection.
  • Page 68: 6)Trace Route

    (6)Trace route It is used to determine path of the IP packet access target. Note: Trace route testing results only for reference, for accurate test route tracking, Please use professional Ethernet tester. Click to enter trace route Input tracking IP address or domain name in the Remote Host IP. Set maximum hop count, normally default is 30 Click "start"...
  • Page 69: Poe Power / Dc12V 3A And Dc 5V 2A Usb Power Output

    Application: Add an IP camera or other network device to the current network group, the new IP address must not be occupied, otherwise it will cause IP conflicts and stop the equipment normal working. Link monitor can check if the new setting IP address is occupied. 3.3.20 PoE power / DC12V 3A and DC 5V 2A USB power output When the tester is turned on, the DC 12V and DC 5V power output functions are automatically turned on.
  • Page 70: Dc 24V 2A Power Output

    Note: 1. Don't input power into the "DC12/3A OUTPUT" port. 2. Don't output this DC12V/3A power to the DC12V/IN port of the IP camera tester to avoid destroy 3. The IPC tester power output is close to 3A, if the IP camera's power is over 3A, the tester will auto enter protection mode.
  • Page 71: Cable Test

    the camera. Notice: a. Don't input any power into the "DC24V/2A OUTPUT"port of the tester to avoid destroy. Man-made damage is not within our company's warranty b. Don't output this DC24V/2A power to DC12V/ IN port to avoid destroy. otherwise the tester will damage, and man-made damage is not within our company's warranty.
  • Page 72: Rj45 Cable Tdr Test

    If need several different number other types cable testers, should pay the additional cost. Cable test Tap "cable test sketch map", pop up Straight-through cable and crossover cable sketch, It is for line sequence reference, when the crystal on the first pressure in the twisted-pair. 3.3.23 RJ45 cable TDR test Connect cable to tester's LAN port, click icon "...
  • Page 73 Repeat test: Continue to test cable status, length and attenuation. Status: After link up, screen display "online", if not link up or open circuit, screen display "open circuit", if cable pair is short circuit, screen display "short circuit". Length: The max test length is 180 meters, when cable is open circuit or short circuit, can test the cable length, if screen display "online", the testing result would be not accurate.
  • Page 74: Cable Tracer ( *Optional )

    Click "Help" to check the instruction of all parameters. 3.3.24 Cable Tracer ( *Optional ) Connect tested cable or BNC cable to the UTP port or the CABLE SCAN (VIDEO OUT) port on the bottom. Click icon to enter, click the Number on the screen to adjust audio type. Page.69.
  • Page 75 UTP mode is used for searching the normal network cable or other cables. STP mode is used for searching the shielded network cable. Rotating the switch of cable tracer to turn on. Clockwise rotation increases sensitivity, anticlockwise rotation reduce sensitivity. Cable tracer and Cable tester can be tested at the same time.
  • Page 76: Tdr Cable Test ( *Optional )

    Note: The battery of the cable tracer must according to corresponding positive pole + and negative pole -, otherwise will damage the tester. Note: While the cable tracer tester is receiving the audio signal from the tester, it may be influenced by other signals and make some noise.
  • Page 77 Open (break point): The curve shows a downward trend after the inflection point 2) Curve operation Zoom: Zoom the curve. Click icon "zoom", tap the curves by two fingers or use virtual keyboard (tap the icon of the screen left edge, to call virtual keyboard) Move: Move curve, click icon "move", and drag the curve to move.
  • Page 78 User-defined calibration: Choose the cable 100 meters to 200 meters (more than 50 meters), click "Cable", "Type" to select user-defined 1 for calibration, 11 groups user-defined can be set. 1. Select user-defined and click "Calibration" to enter test, click "user-defined 1" can define cable name, such as: AiPu BNC-5 2.
  • Page 79: Bnc Attenuation Test ( *Optional )

    Application: TDR test is the use of pulse reflection method, to transmit pulse signal for tested cable, when cable is open circuit or short-circuit, reflected pulse is generated, the tester receives and deals with the reflected wave, measurement results displayed on the screen. TDR can test cable open circuit and short circuit, help engineer quickly find the cable's problem location.
  • Page 80: Poe Voltage Test

    2.After calibration, the red clip clips the copper core of the BNC cable, and the black clip clips the outer envelope of the BNC cable. attenuation value will be displayed after connection, as below: 3.Click "Reset", the application will restore factory defaults. 3.3.27 PoE Voltage test Click icon to enter PoE voltage measurement...
  • Page 81: Power Input Test

    Connect a network cable from a PoE switch to the IP tester's PSE IN port. Connect an IP camera or other PoE using node to IP tester's LAN port, the PoE voltage and the cable's pin connection status show on the screen. Note: This test if for measuring the voltage being drawn by the PoE node and the IP tester must be between the PoE switch and the PoE node for this test to work.
  • Page 82: Digital Multi-Meter ( *Optional )

    Warning: Not allow connect device with input power over 17V to tester "12V IN" port, otherwise it will damage the machine. 3.3.29 Digital Multi-meter ( *Optional ) Click icon to enter. 1) SYMBOLS: U: DC Voltage Measuring A: DC Current Measuring Page.77.
  • Page 83 Ω: Resistance Measuring : Diode Testing : AC Voltage Measuring : AC Current Measuring : Continuity Testing : Capacitance Measuring AC/DC Voltage and current measurement state display Auto- range The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Display the relative measurement value...
  • Page 84 000.0V  660.0V range 000.0mV  660.0mV rang B. AC Voltage Measuring WARNING! You can't input the voltage which more than 660V AC, it's possible to show higher voltage, but it's may destroy the inner circuit. Pay attention not to get an electric shock when measuring high voltage. a.
  • Page 85 00.00mA  66.00mA range 000.0mA  660.0mA range  10.00A range(use 10A socket) 00.00A d. Select the range to enter current measurement NOTE:  When only the figure "OL" is displayed, it indicates over range situation and the higher range has to be selected.
  • Page 86 c. Manual range: 0.000mA  6.600mA range 00.00mA  66.00mA range 000.0mA  660.0mA range  10.00A range(use 10A socket) 00.00A Note:  When only the figure "OL" is displayed, it indicates over range situation and the higher range has to be selected.
  • Page 87 00.00 KΩ  66.00KΩ range 000.0 KΩ  660.0KΩ range 0.000 MΩ  6.600MΩ range 00.00 MΩ  66.00MΩ range F. Continuity Testing WARNING! When testing the circuit continuity, be sure that the power of the circuit has been shut down and all capacitors have been discharged fully.
  • Page 88 H. Capacitance Measuring WARNING! To avoid electric shock, be sure the capacitors have been discharged fully before measuring the capacitance of a capacitor. Ω a. Connect the black test lead to the "COM " jack and the red test lead to the "V/ "...
  • Page 89 Manual range and Auto range When testing, click "Range select" to change the value, click "Auto range" to enter Auto measurement. Data hold Click "Hold data" to enter, the data be hold, the value is green. Press it again to quit. Relative value measurement Click "Relative "to enter, the tester Auto-save the data, the displayed new measurement and relative value is red color.
  • Page 90: Optical Power Meter ( *Optional )

    change the fuse, Pls opens the battery cover to change. Note: 10A socket without fuse protection, if over the current range Wrong using the 10A socket to measure the voltage, will damage the meter. 3.3.30 Optical power meter ( *Optional ) Click icon to enter ,with five wavelength 1625nm,1550nm, 1490nm, 1310nm,1300nm, 850nm, linear or nonlinear optical power display, both for optical power testing and Fiber link loss relative...
  • Page 91 the displayed new measurement and relative value is red color. Press it again to quit. Data hold and Relative measuring use together, the data is yellow while the function is effect. Page.86. Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426...
  • Page 92: Visual Fault Locator ( *Optional )

    3.3.31 Visual Fault Locator ( *Optional ) Click icon to enter VFL four status can select——"Steady mode", "Evasive 1Hz","Evasive 2Hz"and "Time off". Click button "Steady mode" to enter steady status, click button "Evasive 1Hz" and "Evasive 2Hz", to enter pulse mode, click button "Time off ", VFL is turned off. Timed turn off can select (5 mins, 10 mins, 30 mins, 60 mins and 120 mins).
  • Page 93: Audio Record

    3.3.32 Audio Record Connect an audio device to the IP tester's audio input port. Click the icon to enter the Audio Recorder app. Click the red button to stop, and the unit will prompt you to save the recording. 3.3.33 Data monitor Please click icon to enter Click "Setting"...
  • Page 94: Audio Player

    3.3.34 Audio player Click the icon to enter . The audio player only supports MP3 format Audio files. 3.3.35 Media Player Click the icon to enter The Media player can browse video and image files. It supports the video formats of MP4, H.264, MPEG4, and MKV.
  • Page 95: Rtsp Player

    3.3.36 RTSP Player The RTSP Player app will allow you to view the RTSP video stream from an IP camera. If you were unable to view your camera via the ONVIF or IPC Test apps, it is possible your camera will have an RTSP stream and you can view live video.
  • Page 96: Hik Test Tool

    Local IP: This is the IP testers IP address. RTSP Add: This is where you can manually enter the IP camera's RTSP URL or click on Search to search the network for cameras that use an RTSP stream. IPC Username: Enter the IP camera's user name. IPC Password: Enter the IP camera's password.
  • Page 97 "Activation" and "Batch activation" are optional. Auto open ONVIF protocol: After activation, the new HIK cameras click "play, modify the channel name, modify network information, modify user information" any one of to auto open the selected camera ONVIF protocol. Play: Security status shows the "activated" camera. Enter the correct camera password in the right [password] and click [play] to pop up the "private protocol"...
  • Page 98 Modify channel name: Clicking "Modify the channel name" will pop up OSD settings, including time, channel name and other optional items. After channel selecting, you can edit the channel name, modify the display position, and switch the font size. Select "default location" in "content location" is without modification. Select "Customization" to arbitrarily adjust the channel name and display location.
  • Page 99 and other parameters modification. Enter a new IP address and subnet mask, the default gateway will be auto modified according to the IP address. Click "OK" to save the changes. Modify user information: Modify the camera's user name and password. Page.94.
  • Page 100: Dahua Test Tool

    Factory Reset: Camera factory reset. 3.3.38 Dahua test tool Dahua test tool is developed for installation and debugging of the Dahua IP camera, it can display image, and modify IP, user name and password etc. Making Dahua camera test more convenient and quickly.
  • Page 101 Activation: select left [online detection] to display the "inactivated" camera and click activate. Activate and Batch activate are optional, support reserved phone number for resetting password. Page.96. Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426...
  • Page 102 Play: When mode display "activated" camera, input correct password, click "Play" poping up "private protocol" and "ONVIF", Select correspond protocol to view the camera image. Modify Channel: Click "Modify Channel", will pop up OSD setting, includes time, channel name,etc Page.97. Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426...
  • Page 103 After selected Channel name, can edit channel name, modify the display position and font size. If select "Default position" of Content location, then no need to modify. If select "customize", then can modify Channel name and display position, click "OK"to view the image. Click "Back" or "Return" button to return previous interface.
  • Page 104 Input new IP address, need to input password, click "OK" to save the modification Modify user information: Modify camera user name and password, which is onvif, Dahua test tool, IPC TESTE user name and password, not web user name and password. Page.99.
  • Page 105: Update

    Factory reset setting: Camera will be soft reset, and the device's user name, password and network set be saved. Other settings information is factory reset. 3.3.39 Update Copy the downloaded update file to SD card "update" directory, if no directory, please create one. Click the icon to open the Update menu.
  • Page 106: Office

    If there are update programs, applications will be listed in the interface, click related applications, update to the latest version. Update online: Before using online update, need enter settings-user management to register first. System update: Connect the Internet to update systems. 3.3.40 Office Quick office app (support excel, word, ppt format) doc.
  • Page 107: Led Flashlight

    3.3.41 LED Flashlight It is convenient for the installation or maintenance in the evening or in the dark. Click icon enter While in the flashlight app, click the red button to turn on the LED lamp. Press it again to turn it off. If you don't press the red button to shut off the lamp and press the button to exit the app, the lamp will stay on.
  • Page 108: Notepad

    camera. If they are not in the same segment, click the button or press "RETRUN" to exit. Open the "Settings" app from the main menu to change the IP tester's network settings to match those of the IP camera. 3.3.43 Notepad Notepad can be used to record the important testing results, click the key "Save"...
  • Page 109: System Setting

    3.3.44 System Setting Click icon to enter Language: Select your desired language: English, Chinese, Korean, Russian, Italian, Polish, Spanish, French or Japanese, German,Turkish,etc. Typewriting: You can select typewriting or install other typewriting: Date/Time: Set the Date/time of the IP tester IP setting: Manually set the IP address, Subnet Mask, Default Gateway and DNS address or select "Dynamic allocation"...
  • Page 110 click "Add " to enter another IP address for the IP tester. After setting an advanced IP address (refer to the photos above), the unit can test two network segments (192.168.5.0) and (192.168.1.0) WLAN Net: Turn WiFi off or on by pressing the "Open the wifi" button. Once WiFi is turned on, and click connected WIFI, it will scan for wireless networks in your area.
  • Page 111 Wi-Fi hotspot: Input "SSID" name and "password", and then click "ok" to create Wi-Fi hotspot. Brightness: Set the desired brightness of the IP tester and adjust the sleep time settings. Volume: Set volume level SD Card: Displays SD Card Capacity. You can also format the SD card or unmount it before removing FTP server: Once the IP tester connects to a network, a computer can be used to read the SD card files via FTP Page.106.
  • Page 112 Start the FTP server and then input the tester's FTP address in the PC's address bar. This will enable the PC to read, copy and edit the files from the SD card without the use of SD card reader. Version Information: Shows applications version information, if press any apps icon several seconds to uninstall.
  • Page 113: File Explorer

    and write your feedback. Lock Screen: The meter default is not locked. You can choose password Lock screen, pattern Lock screen or "NO". Password Lock Screen: Set password, you can input digitals, letters or characters as password, input it again to confirm .when the meter is in standby mode or turn it on, you can input your password to enter. Pattern Lock Screen: Drawing a pattern to lock.
  • Page 114: Theme

    FTP server You can choose internal or external SD card. Other operation details, Please refer to FTP settings. 3.3.46 Theme Desktop style: you can select Lite mode or normal mode. Theme: Pressing square area's any color icon several seconds, the selected color icon will be auto move the rectangle area, if you press selected color several seconds, and it will be auto deleted.
  • Page 115 Theme colors include fixed order and random order, and click "set" to save. Color When set background color, you can select colors from Color Phase, and also can input color's RGB to set. After finished color setting, click "set" to set it as desktop or application background. Page.110.
  • Page 116: Audio Test

    Set as desktop background: Setting color as desktop background. Set as application background: Set color as application background. Set at the same time: Setting color as desktop background and application background. Cancel: Cancel current setting. Picture: Click Picture to select one, and set as temporarily background to view setting effect. Click "more" to select pictures from local file, and click set to set picture as background.
  • Page 117: Specifications

    4. Specifications 4.1 General Specifications IP Camera Tester【*】models Optional Model Display New 7 inch retina touch screen, 1920*1200 resolution Network port 10/100/1000M auto adjust, RJ45, Dual LAN port Built in WIFI, speeds 150M, allows you to connect to a wireless network WIFI and view IP cameras H.265 Mainstream...
  • Page 118 2160P 20/30 fps, UTC control and call OSD menu 1 channel CVI input(BNC interface, resolution support 720P CVI video signal test * 25/30/50/60fps,1080P 25/30fps, 2560x1440P 25/30fps, 2592x1944 20fps, (Optional) 2960x1920 20fps, 3840 x 2160 12.5/15 fps. UTC control and call OSD menu 1 channel TVI input(BNC interfce),resolution support 720P TVI video signal test*...
  • Page 119 Under normal mode, you can change icons sequence and self-define the Screen management number of icons in each page Self-define icons, desktop and application interface background, modify Theme interface sliding effect. PoE power switch, IP setting, WLAN switch, HDMI IN functions etc screen drop-down menu lock, password lock screen or pattern lock 1 channel audio signal input and 1 channel audio signal output to connect...
  • Page 120: Multi-Meter Specifications

    *(Optional) TDR cable test BNC cable, network cable, telephone cable, RVV cable and elevator cable, cat 5/6 cable’s length and short circuit. measurement range 1.2KM *(Optional) Through hardware high-speed sampling and processing technology, test the BNC attenuation test BNC coaxial cable transmission attenuation value, detect the transmission *(Optional) quality of BNC cable.
  • Page 121 DC voltage Range Accuracy Resolution 660mV (Manual range) 0.1mV 6.600V ±(0.3%+4) 66.00V 10mV 660.0V 100mV AC voltage Range Accuracy Resolution 660.0mV (Manual range) ±(1.5%+6) 0.1mV 6.600V 66.00V ±(0.8%+6) 10mV 660.0V 100mV DC current Range Accuracy Resolution 6.600mA 66.00mA 10uA ±(0.5%+3) 660.0mA 100uA 10.00A...
  • Page 122 Resistance Range Accuracy Resolution 660.0Ω 0.1Ω ±(0.8%+5) 6.600KΩ 1Ω 66.00KΩ 10Ω ±(0.8%+2) 660.0KΩ 100Ω 6.600MΩ 1KΩ 66MΩ 10KΩ ±(1.2%+5) Continuity Range Resolution Function The measurement value less 30Ω±3Ω,the tester will 660.0Ω 0.1Ω sound Diode Range Resolution Function Schottky diode:0.15~0.25V 2.0V rectifier diode:0.6~1.0V triode PN junction:0.5~0.8V Schmidt and Muller Telecommunications Pty Ltd trading as ELECTROCRAFT AUSTRALIA - ABN 79 067 000 426...
  • Page 123: Optical Power Meter Specifications

    660.0μF 100nF 1μF 6.600mF ±(5%+8) 10μF 66.00mF 4.3 Optical power meter specifications -70~+10dBm Measure Range(dBm) Wavelength(nm) 850nm,1300nm,1310nm,1490nm,1550nm,1625nm Detector InGaAs <±3%dB(-10dBm,22℃) <±5%dB(full range,22℃) Uncertainly Display Resolution Linear:0.1% ; Nonlinear:0.01dBm -10~+50 Operating Temperature(℃) -20~+70 Storage Temperature (℃) Connector type FC/PC 4.4 Visual fault locator specifications Laser type Wavelength Calibration 650nm...

Table of Contents