Summary of Contents for Crystal Vision FR2AV

  • Page 1 FR2AV 2U frame Crystal Vision Ltd., Lion Technology Park, Station Road East, Whittlesford, Cambridge, CB22 4WL, England. E-mail: sales@crystalvision.tv Website: www.crystalvision.tv Tel: +44(0) 1223 497049 Fax: +44(0) 1223 497059...
  • Page 2: General Safety Summary

    To avoid overheating provide proper ventilation. Only use this rack in conjunction with Crystal Vision modules designed for that purpose. Do not use the frame unless all the rear connector positions are filled, either with Crystal Vision Rear Modules, or with Crystal Vision blanking plates.
  • Page 3: Table Of Contents

    FR2AV FRAME USERS MANUAL FR2AV FRAME issue 111 Manual.doc BF 22/07/01 FR2AV S/W 1.5 onwards CONTENTS ..........................2 ENERAL AFETY UMMARY ..............................4 NTRODUCTION ..............................5 PECIFICATION ............................5 AINS ONNECTIONS ..............................5 OWER UPPLIES ....................5 RONT ANEL NDICATION UPPLY TATUS ............................6 IDEO UDIO CARDS ..........................6...
  • Page 4: Introduction

    Introduction The FR2AV frame provides the connections and supplies for up to 12 Crystal Vision video or audio modules in 2U of rack height. The frames provide configurable rear connections and the facility for two separate plug-in power supplies. The dual supply facility allows for redundancy and continued operation in the event of a power supply failure.
  • Page 5: Specification

    See the “maintenance” section for information on fan replacement. With an FR2AV the power indication LED will change from green to red if one of the power supplies develops a fault ( the red fail LED on the front of the associated power supply will also light up ). The position of the link on header J2 depends on the number of power supplies in the frame.
  • Page 6: Video/Audio Cards

    GPI connections. Video/Audio cards The frame has twelve slots for Crystal Vision video or audio cards. Only Crystal Vision cards should be fitted. The signal connections to these are made through rear modules. The operation and connections of each card and associated rear modules are described in the documentation relating to that card.
  • Page 7: Slot Numbers

    These are given the letters 'a' to 'f' in the documentation supplied with the Crystal Vision video or audio card. Depending on the type of card and its configuration these may be RS422 or GPI connections. The following tables should be used together with the card documentation to determine the signal connections.
  • Page 8 Remote 4 pin 14 open on fault Remote 4 pin 23 close on fault Remote 4 pin 5 Note the current though the relay contacts should be limited to a maximum of 200mA. Page 8 of 13 FR2AV user manual issue 1.1.1...
  • Page 9 View from rear of FR2AV Frame showing rear connectors CAUTION. This equipment may have more than one This equipment must be earthed power supply cord. To reduce risk of electric shock disconnect all (one or two ) power supply cords...
  • Page 10: Fp2-Lf Lcd Front Panel Control Module On The Fr2Av Frame

    FP2-LF LCD Front Panel Control Module on the FR2AV Frame. Using the Front Panel Controls The front panel module FP2-LF fitted to the FR2AV frame allows control of suitable Crystal Vision Audio/Video cards without opening the frame front panel. Front panel control uses a two-line by twenty-character alphanumeric display to guide the user through the control process.
  • Page 11: Remote Control Panels

    The REM1U is a 1U remote control panel. 482mm (19 inches ) and 85mm deep. The REM1U can be powered by a mains adapter (supplied with REM1U) or via the dc power output on the FR2AV frame ( pin 15 of REMOTE 2). The mains adapter has a dc output voltage of +5.6Vdc which connects into a 3pin locking DIN connector on the rear of the REM1U.
  • Page 12: Rem1Us

    REM1U. It is possible for the REM1U to control two FR2AV frames. In this case the multi-core cable from the REM1U connects to the first FR2AV frame as described in the above table, and then a cable loops out of the REMOTE 2 connector to another REMOTE 2 connector which is connected to a second FR2AV frame.
  • Page 13: Replacing The Mains Input Fuses

    If a fuse blows repeatedly this indicates a fault either in the associated power supply module or elsewhere. Return the frame and/or power supply to the manufacturer or dealer for repair. End of document. Page 13 of 13 FR2AV user manual issue 1.1.1...