KMB KATKA 80ST 690 Operating Manual

Thyristor switching modules

Advertisement

Quick Links

KMB systems, s. r. o.
Dr. M. Hor´ a kov´ e 559, 460 06 Liberec 7, Czech Republic
E-mail: kmb@kmb.cz, Web: www.kmb.cz
Operating Manual for
THYRISTOR SWITCHING MODULES
KATKA 80ST 690
version 2.0
The complete and most actual version of this manual is available online at http://www.KMB.cz/

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KATKA 80ST 690 and is the answer not in the manual?

Questions and answers

Summary of Contents for KMB KATKA 80ST 690

  • Page 1 Dr. M. Hor´ a kov´ e 559, 460 06 Liberec 7, Czech Republic E-mail: kmb@kmb.cz, Web: www.kmb.cz Operating Manual for THYRISTOR SWITCHING MODULES KATKA 80ST 690 version 2.0 The complete and most actual version of this manual is available online at http://www.KMB.cz/...
  • Page 2: Table Of Contents

    2.2 Internal Wiring of KATKA 80ST 690 ....... . .
  • Page 3: Applications

    Applications KATKA 80ST 690 series of thyristor switching modules have been designed especially for switching power factor correction capacitors in rapid reactive power compensation (up to 20 control interventions in one second) in conjunction with fast power factor controllers of the NOVAR series. They can, of course, be also used in other applications where contact-less load switching is required.
  • Page 4: Connections

    Power (a) Fan will turn on when hot (b) Fan will be on permanently Figure 1: Connection of fan supply voltage to KATKA 80 Internal Wiring of KATKA 80ST 690 L1 L2 L3 KATKA T KATKA ST L1 C1 L2 C2 L3 C3...
  • Page 5: Installation Of Katka Into Cabinet

    Installation of KATKA into cabinet During normal operation, modules produce great amount of heat. Therefore it’s necessary to provide sufficient air flow in the cabinet (holes in bottom and top of the cabinet) and sometimes also use of active cooling (use of fan) might be necessary.
  • Page 6: 1-Phase Star Connected Capacitors

    690 V/400 V systems. 690V/400V L1 L2 L3 KATKA ST L1 C1 L2 C2 L3 C3 Figure 4: 1-phase star connected capacitors System Voltage Max. step output Current/phase 3 Ö 26,8 kvar KATKA 80ST 690 690V 67 A Table 1: Maximum allowed power...
  • Page 7: Connection Of Control Signal To Katka 80St 690

    Connection of Control Signal to KATKA 80ST 690 The control voltage is galvanically isolated from the other circuits. The modules have a Power indicator, to indicate voltage presence, and a Control indicator to indicate closed circuit condition of the module when control voltage is applied.
  • Page 8: Mechanical Dimensions

    KATKA 20T 400 KATKA 20T 690 KATKA 80T 400 KATKA 80T 690 KATKA 20D 400 KATKA 80D 400 Parameter KATKA 20ST 400 KATKA 20ST 690 KATKA 80ST 400 KATKA 80ST 690 400V/230±10% 400/230±10% nom. operating volt. 400V/230V±10% 690V/400V±10% 400V/230V±10% 690V/400V±10% 440V/250V±10% 440/250±10% max.
  • Page 9: Ordering Diagram

    Ordering Diagram KATKA 8OT 4OO Instrument Class KATKA9=9Thyristor9switching9module Construction and power 2O9=9passive9cooling,9up9to922A93T,9STV/up9to929A3DV9 8O9=9active9cooling,9up9to967A93T,9STV/up9to987A3DV Switching method D99=9two-phase,9two9thyristors T99=9three-phase,9three9thyristors ST9=9individual9switching9of9each9phase,9three9thyristors System Voltage 4OO9=94OO/23OV9up9to944O/25OV 69O9=969O/4OOV93available9only9for9option9T9and9STV...
  • Page 10: Accessories

    Accessories Discharge resistors 3pcs of Auxiliary discharge resistors 33kΩ / 13W are delivered with thyristor modules. Resistors are designed to be used with connection on fig. ??. Its possible to connect resistors directly to terminals of capacitors. ZP 24 auxiliary power supply Auxiliary supply 24 VDC is necessary for thyristor switches modules or auxiliary relays excitation.
  • Page 11: Maintenance, Service, Warranty

    Maintenance, Service, Warranty Maintenance: the KATKA 80ST 690 modules does not require any special maintenance during its operation but following should be respected. For reliable operation heat sink should be cleaned regularly from any debris and dust as cooling performance can be reduced otherwise. Also regular inspection of fan operation (when equipped) should be performed.