INSTALLATION GUIDE www.kalefans.net KALE FANS Contents Preface…………………………………………………………………………………………………2 Production series introduction……………………………………………………..3 Product specification table…………………………………………………3 Product drawing………………………………………………………………………4 Standard components introduction……………………………………5 Packing list…………………………………………………………………………6 Universal installation tools…………………………………………………8 Installation conditions and types………………………………………………….8 Roof installation requirement……………………………………………8 I-beam steel structure………………………………………………………9 Concrete structure…………………………………………………………….9 Angle-concrete bent structure……………………………………………9 Fan installation procedures………………………………………………………….10 Specification of parameters for control system.…………………………….13...
BOREAS INSTALLATION GUIDE Preface Thanks and congratulate for your purchasing of the KL-HVLS series big energy-saving fan! Now you have acquired the most effective shortcuts to pass a cool summer and warm winter. No matter in the industrial or utility applications, it possesses relatively high cost performance.
BOREAS Series fan is a primary product for KALEFANS and its coverage can be up to 1600 sq metres. The fans are mainly applied in large space such as the plant, logistics &...
BOREAS INSTALLATION GUIDE Product drawing Steel structure Winglet of fan blade Safety ring Fan blades Steel structure fastening Turnbuckle and clamps Extension tube Traction steel wire Main body I-type safety adapting pieces...
INSTALLATION GUIDE www.kalefans.net KALE FANS Standard components introduction 3 Steel structure fastening 5 Main body structure fastener pressure plate main body frame shim motor housing steel structure power system top plate grommet for adapting piece steel wire for extension tube...
BOREAS INSTALLATION GUIDE Packing list HOUR SERVICE HOTLINE F R O M K A L E F A N S Be for e opera ting the uni t, p le ase re a d the p rod uc t d esc r ip tio n c a re fu lly ,a nd c le a r obs tac le s f rom the re gio na l o per a ti on.Ensur e t he re is eno u g h d ist anc e fo r t he fa ns runni ng.
Page 8
INSTALLATION GUIDE www.kalefans.net KALE FANS Packing specification Gross DIMENSION Volume CASE NO weight Remark (L*W*Hmm) (m ) (kg) fan blade 3750*415*390 0.61 carton Packing details DESCRIPTION Fan Blade Extension Tube Cardan Joint Fastener 2019...
BOREAS INSTALLATION GUIDE Fan installation procedures Preparation Notice: When unloading product should put down gently when unloading, product’s position should not affect the field production and channel. Notice: Carefully confirm the following information 1, Installation point 2, installation confirmation height 3, whether there are obstacles (such as crane, light, Cable, fire protection, cameras) 4, control cabinet position 5, the input power and the power cord layout, 6, power line layout, 7, traction steel wire position.
Page 12
INSTALLATION GUIDE www.kalefans.net KALE FANS Main body Notice: keep the upper and under plane horizontal, then tighten up the relevant bolts. Notice: Don't cut the copper wire when stripping off, first connect ground wire wiring (yellow-green one or yellow one if no yellow-green), connect one-to-one according to the color and then wrapped with insulating tape.
Page 13
BOREAS INSTALLATION GUIDE Notice: the oval hole is under the round hole. I-type pieces control system Notice: the height from floor to the bottom of the control box should be around 1.2 meter. wiring Notice: distinguish the input and output, also make sure the ground wire is in place. Notice: all the parameters had well set before delivery in factory.
BOREAS INSTALLATION GUIDE Operating instructions Three gears control switch Three gears control switch is the electrical device that controls OFF, RUN and Reset, and is belongs to weak current control switch. It directly controls the frequency converter. Run: Fans are running forward, winds blowing downward.Off: Fans stop running.Reset.
INSTALLATION GUIDE www.kalefans.net KALE FANS Caution The installation and layout of the circuit wiring must be performed by our professional qualified staff. Please use the specified device component appointed by our company. While the fan is running, please don’t cut off the power, otherwise it will cause damage to the fan. It should cut off the power when the fan is drop-dead halt.
BOREAS INSTALLATION GUIDE No. Description Warning Alarm Trip Error Cause of Problem Lock Motor phase V missing Motor phase V is missing. Check the phase. Motor phase W missing Motor phase W is missing. Check the phase. Internal fault Contact local Danfoss supplier. Earth fault Discharge from output phases to ground.
INSTALLATION GUIDE www.kalefans.net KALE FANS 10. Fan working condition In order to take full advantage of the product's performance and extend its life, the installation environment if of very important. Please install the fan in the environment as requested in the following table:...
BOREAS INSTALLATION GUIDE 12. Warranty and maintenance Our product design is maintenance-free, but in order to ensure the long life of the normal operation, the fan should also be maintained regularly, especially when applied in harsh environments. For any fan or inverter controller maintenance, please be sure that the fan stops running and cut off the controller power to protect the safety of personnel.