Facade Removal - Vector VREF12-LB-RGD Operation And Service Manual

Refrigerators and freezers
Table of Contents

Advertisement

Component Details
Model
Gas Type
VFZR25-LB-RSD
R290
VFZR25-LB-LSD
VFZR49-LB-RSD
R290
VREF12-LB-RGD
R290
VREF12-LB-LGD
VREF12-LB-RSD
R290
VREF25-LB-RGD
R290
VREF25-LB-LGD
VREF25-LB-RSD
VREF30-LB-RGD
R290
VREF30-LB-LGD
VREF30-LB-RSD
VREFCR30-RGD
R290
VREF49-LB-OGD
VREF49-LB-OSD
VREF49-LB-SGD
VREF72-LB-RSD
R290
VREF72-LB-RGD
Vector Lab Products Refrigerators and Freezers
Gas
Low side
Charge
pressure at
70°F
3 .9 oz
2 .9 psig
(0 .110 kg)
(0 .2 barg)
4 .2 oz
4 .35 psig
(0 .120 kg)
(0 .3 barg)
2 .5 oz
29 psig
(0 .070kg)
(2 barg)
2 .5 oz
29 psig
(0 .070 kg)
(2 barg)
3 .2 oz
37 .71 psig
(0 .09 kg)
(2 .6 barg)
3 .5 oz
24 .65 psig
(0 .100 kg)
(1 .7 barg)
3 .5 oz
17 .40 psig
(0 .100 kg)
(1 .2 barg)
2 x 3 .2 oz
2 x 37 .71
(2 x 0 .090 kg)
(2 x 2 .6 barg)
High side
Compressor Windings
pressure at
70°F
149 .39 psig
Start winding = 5 .99 Ω
(10 .3 barg)
Run winding = 1 .10 Ω
150 .84 psig
Start winding = 2 .66 Ω
(10 .4 barg)
Run winding = 0 .43 Ω
146 .5 psig
Start winding = 6 Ω
(10 .1 barg)
Run winding = 3 .7 Ω
146 .5 psig (10 .1
Start winding = 13 .35 Ω
barg)
Run winding = 4 .89 Ω
156 .64 psig
Start winding = 13 .35 Ω
(10 .8 barg)
Run winding = 4 .89 Ω
165 .4 psig
Start winding = 7 .19 Ω
(11 .4 barg)
Run winding = 1 .57 Ω
149 .39 psig
Start winding = 7 .19 Ω
(10 .3 barg)
Run winding = 1 .57 Ω
2 x 156 .64 psig
Start winding = 13 .35 Ω
(2 x 10 .8barg)
Run winding = 4 .89 Ω
Locked
at 77°F
Rotor (A)
40
55
16 .7
19 .6
19 .6
30
30
19 .6
13