Magnum M9-IAQS Manual

Indoor air quality monitor & data logger

Advertisement

Quick Links

Indoor Air Quality Monitor & Data Logger
M9-IAQS
Description
M9-IAQS is an indoor air quality controller with screen provides customers with visual indoor air quality readings,
such as PM2.5, CO2, temperature, humidity, etc.; It can control the HVAC system directly. For example: Adjust the
fan speed, control air supply / exhaust, set mode and other functions. It is widely used in residential, commercial
and industrial applications, and can effectively improve air quality and create a healthy, comfortable,
efficient, environmentally friendly, energy-saving living and working environment.
Features
Compatible with embedded and wall-mounted fixing methods;
▪Compatible with push-button and touch-screen operation;
▪Using standard 86 box size, thickness <24mm;
▪PM2.5, CO2, RH&T etc., multiple sensors can be optionally selected.
▪With fresh air control function, three level speed of wind can be adjusted, four working modes: intelligent,
manual, mute, and periods.
▪Customizable filter alert function.
Working Principle
The built-in dust sensor uses the principle of laser scattering technology to detect the indoor PM2.5 mass
concentration in real time(μg/m³);
The built-in carbon dioxide sensor uses the principle of NDIR technology to detect indoor CO2 concentration in real
time (ppm);
The RH&T sensor use capacitor resistance material to detect the indoor temperature (° C) and humidity (%) in real
time.
www.MagnumFirst.com
Applications
Residential ventilation system
Business ventilation system
Industrial ventilation system
2/11

Advertisement

loading

Summary of Contents for Magnum M9-IAQS

  • Page 1 Industrial ventilation system Description M9-IAQS is an indoor air quality controller with screen provides customers with visual indoor air quality readings, such as PM2.5, CO2, temperature, humidity, etc.; It can control the HVAC system directly. For example: Adjust the fan speed, control air supply / exhaust, set mode and other functions. It is widely used in residential, commercial and industrial applications, and can effectively improve air quality and create a healthy, comfortable, efficient, environmentally friendly, energy-saving living and working environment.
  • Page 2: Specifications

    Specifications Specifications :NDIR Working principle PM:Laser scattering principle PM2.5:0~1000μg/m³ :0~5000ppm Measurement range Temperature:-10℃~50℃ Humidity:0%~95%RH ≤ 100μg/m³:±10μg/m³ PM2.5 Measurement accuracy > 100μg/m³:±10% reading (Reference Instrument TSI 8530,25±2℃,50±10%RH) Measurement accuracy ±(50ppm+5% of reading)@ 0~50℃ Temperature Measurement ±1℃ accuracy Humidity Measurement accuracy ±8%RH PM Response time T90 ≤8s Response time T90...
  • Page 3 Dimensions and Interface Definition Dimensions (Unit : mm, tolerance : ±0.2 mm) 2. Pin definition Description Communication port(RS485_TA) Communication port(RS485_TB) +12V Power input(+12VDC/24VDC available) Power input(GND) www.MagnumFirst.com 4/11...
  • Page 4 UI Interface Description Parameter Range corresponding to color LIST Level Range Color Good 0~75 PM2.5 Just so so 75~115 (μg/m³) ≥115 Good 0~600 Just so so 600~1000 (ppm) ≥1000 www.MagnumFirst.com 5/11...
  • Page 5 Controlling Instructions 1 Working Mode Manual Mode: The user can adjusts the fan speed switch manually (high, middle and low);; Intelligent Mode: According to the setting value of PM2.5 or CO2, it can switch the fan speed automatically. Mute Mode: Operation at low speed; Periods Mode: The user can set different fan speed in four periods within 24 hours (00: 00 ~ 06: 00, 06: 00 ~ 12: 00, 12: 00 ~ 18: 00, 18: 00 ~ 24: 00) 2 Key’s Function...
  • Page 6 ①Without CO2 sensor: the controller automatically adjusts the fan speed according to the air quality (PM2.5 concentration); when the PM2.5 concentration is higher than the set value of 115μg / m³, the fan runs at high speed; when the PM2.5 concentration is between 75-114μg / m³, the fan runs at medium speed; when the PM2.5 concentration is lower than the set value of 75 μg / m³, and the fan runs at low speed.
  • Page 7: Installation Instructions

    Installation Instructions Step 1: Fix the wall mounted bracket with screws on the 86 box which in the embedded wall, as shown below Step 2: Connecting Cable, connect the corresponding cable to the controller's RS485 interface according to the interface definition, as shown below: Step 3: Match the two holes in the controller with the hooks in the wall mount bracket and slide the controller down to ensure that the controller is tightly locked with the bracket.
  • Page 8: Precautions For Use

    Precautions for use ▪ Do not place the controller in an environment where the ambient temperature is too high (above 60 ° C) or too low (below -20 ° C). ▪ Keep it out of reach of children as much as possible to prevent injury from collision and fall. ▪...
  • Page 9: Communication Protocol

    Communication Protocol 1. General Statement 1) The M9-IAQS controller is connected to the HVAC controller through 485, it sends a command to the HVAC controller to achieve the AM6108 control the HVAC system by communication protocol. 2) Baud rate:9600, Data Bits: 8, Stop Bits: 1, Parity: No;...
  • Page 10 DF4=0x01 VOC L1 (1-3) DF4=0x02 VOC L2 DF4=0x03 VOC L3 Error code DF15- DF16 Reserved Reserved DF17- DF18 Reserved DF19- DF20 CheckSum After-Sales Services and Consultancy Magnum First Corporation 370 Falls Commerce Parkway Cuyahga Falls, OH 44224 716-293-1588 sales@magnumfirst.com www.MagnumFirst.com www.MagnumFirst.com 11/11...