Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Brooks Manuals
Card Reader
FluidX Scope USB
User manual
Brooks FluidX Scope USB User Manual
Hide thumbs
1
2
3
4
5
6
7
Table Of Contents
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
page
of
23
Go
/
23
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Introduction
Installation
Attaching the Cable
Detaching the Cable
Reading a Tube
Reading a Linear Barcode
Reader Feedback
Quick Setup Codes
Preventative Maintenance
Appendix A. Declaration of CE Conformity
Advertisement
Quick Links
1
Installation
2
Reading a Tube
3
Quick Setup Codes
Download this manual
FluidX Scope USB
User Manual
Part Number 281947 Rev. C
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Summary of Contents for Brooks FluidX Scope USB
Page 1
FluidX Scope USB User Manual Part Number 281947 Rev. C...
Page 2
Independent Twin Linear Exchange™, InCooler™, InLigner™, I nterface™, I soport™, ITLX™, Jet™, Jet Engine™, LEAP™, LowProfile™, M2 Nano™, PASIV™, PowerPak™, PerformanceBlue™, Plate Auditor™, PowerPak™, PowerTools™, QuadraFly™, Radius™, R adient™, Radient Express™, RapidThaw™, Reliance™, Reliance ATR™, RetroEase™, SCARA™, SmartPM™, SPOTLevel™, Sprint™, Synetics™, The New Pathway to Productivity™, Time Optimized Trajectory™, Time Optimal Trajectory™, Time Optimized Path™, TopCooler™, TopLigner™, Tube Auditor™, Ultimate Blue™, VAC-407™, VacuTran™, VersaPort™, and WaferEngine™ are trademarks of Brooks Automation, Inc. AcuTran®, AquaTrap®, A syst®, the Cool Solutions logo, Crossing Automation®, Cryodyne®, Cryo-Torr®, Fusion®, GOLDLink®, Guardian®, GUTS®, H elix®, Leapfrog®, MagnaTran®, MapTrak®, Marathon®, Marathon 2®, Marathon Express®, On-Board®, Polycold®, Razor®, R EMP®, Spartan®, T rueBlue®, TurboPlus®, Vision®, Xpeel®, XTape®, Zaris®, the Brooks logo, and the Brooks Life Sciences logo are registered U.S. trademarks of Brooks Automation, Inc. All other trademarks are properties of their respective owners. © 2020 Brooks Automation, Inc. All rights reserved. The information included in this manual is proprietary information of Brooks Automation, Inc. and is provided for the use of Brooks customers only and cannot be used for distribution, reproduction, or sale without the express written permission of Brooks Automation, Inc. This technology is subject to United States export Administration Regulations and authorized to the destination only; diversion contrary to U.S. law is prohibited. Original manual printed in English. Copyright © 2020, Brooks Automation, Inc.
Page 3
Contact Number Website North +1-800-447-5007 (Toll Free) http://www.brooks.com/ +1-978-262-2900 (Local) America +49 800 000 9347 (Toll Free Europe Germany) http://www.brooks.com/ +49 364 176 9999 6 (Has Toll) +81 120-255-390 (Toll Free) Japan http://jp.brooks.com/ +81 45-330-9005 (Local) China +86 400 627 6657 http://cn.brooks.com/ +886 080-003-5556 (Toll Free) Taiwan http://tw.brooks.com/ +886 3-5525258 (Local) Korea 1800-5116 (Toll Free) http://kr.brooks.com/ +65 1-800-4-276657 (Toll Free) Singapore http://www.brooks.com/ +65 6309 0701 (Local) Contact Technical Publications directly: Technical.Publications@brooks.com Accelerating Innovation Copyright © 2020, Brooks Automation, Inc.
Page 4
Brooks Automation Brooks Automation (Israel) Ltd. (Germany) GmbH Mevo Yerach 5 im Wiesengrund 17 Kiryat-Gat 82000 78315 Radolfzell, Germany Israel Tel: +49-7732-9409-0 Tel: +972 8672 2988 Fax: +49-7732-9409-200 Fax: +972 8672 2966 Brooks Automation, Inc. Life Science Systems AIM Servicios Administrativos Brooks Automation AG S de RL de CV Bernstrasse 134 Carretera Huinalá km 2.8 CH-3613 Steffisburg Parque Industrial Las Américas 66640 Switzerland Apodaca, NL Mexico Tel: +41 (0) 31 770 70 70 Tel: +52 81 8863-6363 Copyright © 2020, Brooks Automation, Inc.
Page 5
Tel: +81-45-477-5570 Fax: +65-6836-3177 Fax: +81-45-477-5571 Copyright © 2020, Brooks Automation, Inc.
Page 6
Tel : +82-31-288-2500 Fax (Sales): +886-3-552 5200 Fax: +82-31-287-2111 Brooks Japan K.K. Brooks Automation Ltd. KUMAMOTO SERVICE TAINAN OFFICE OFFICE 3F., No.11, Nanke 3rd Rd., Xinshi Dist. 202 Mirai Office II Tainan Science Park 312-1 Tatsudamachi Yuge Tainan City 74147, Taiwan (R.O.C.) Tatsuda, Kumamoto 861-8002 TEL: +886-6-505-0268 Tel: +81-96-327-9720 FAX: +886-6-505-5228 Fax: +81-96-327-9721 Copyright © 2020, Brooks Automation, Inc.
Page 7
ECO Number Date of Changes Initial Revision 5 07/2014 completion of the manual. Revision A 95874 4/25/2017 Image Updates Brooks Re- Branding and Revision B EC107106 10/1/2018 application of Brooks Templates. Updated: New barcodes in chapter Quick Setup Codes. Revision C EC118417 3/12/2020 LED and audio feedbacks in chapter Reader Feedback. Copyright © 2020, Brooks Automation, Inc.
Page 8: Table Of Contents
Brooks Automation FluidX Part Number: 281947 Rev. C Table of Contents 1. Introduction 2. Installation 3. Attaching the Cable 4. Detaching the Cable 5. Reading a Tube 6. Reading a Linear Barcode 7. Reader Feedback 8. Quick Setup Codes 9. Preventative Maintenance Appendix A. Declaration of CE Conformity viii Copyright © 2020, Brooks Automation, Inc.
Page 9: Introduction
Brooks Automation Part Number: 281947 Rev. C 1. Introduction The Scope USB single tube reader from FluidX is a sophisticated 2D Data Matrix code reader. It is capable of reading standard pre-coded tubes from a range of manufacturers, assuming they adhere to the ISO 16022 Data Matrix Two Dimensional Bar Code format. The Scope USB can also read linear barcodes, and the single tube reader has a larger viewing window to improve readability. Copyright © 2020, Brooks Automation, Inc.
Page 10: Installation
Brooks Automation FluidX Part Number: 281947 Rev. C 2. Installation The system has been designed with minimal user setup and no software is required, the USB connector cable is already fitted. Step Action Ensure the connector cable is fully inserted into the Scope reader, then connect the USB end to the USB port on the host device to power up the reader. The unit will beep twice and the LED will turn off. The Scope USB is now ready for use. NOTE: Any 2D Coded Tube scanned will be sent directly through the keyboard buffer to wherever the cursor is blinking. Copyright © 2020, Brooks Automation, Inc.
Page 11: Attaching The Cable
Brooks Automation Part Number: 281947 Rev. C 3. Attaching the Cable The RJ50 cable is a multi-pin connector and can be damaged if handled incorrectly. Ensure that the cable is fully pushed home. Errors may occur if the cable is not properly installed. Copyright © 2020, Brooks Automation, Inc.
Page 12
Brooks Automation FluidX Part Number: 281947 Rev. C Step Action The connector cable is already attached, but if necessary the cable can be inserted by slotting the RJ50 connector into the reader. NOTE: Ensure it is in the correct orientation. Copyright © 2020, Brooks Automation, Inc.
Page 13: Detaching The Cable
Brooks Automation Part Number: 281947 Rev. C 4. Detaching the Cable Detaching a cable from the FluidX Scope USB is simple. Step Action Insert one end of a paperclip into the hole on the back of the reader. Copyright © 2020, Brooks Automation, Inc.
Page 14
Brooks Automation FluidX Part Number: 281947 Rev. C Step Action Apply pressure on the paperclip and gently pull the cable from the reader. Copyright © 2020, Brooks Automation, Inc.
Page 15: Reading A Tube
Brooks Automation Part Number: 281947 Rev. C 5. Reading a Tube The FluidX Scope USB makes reading tubes easy. By default, the device is not in continuous scanning mode, so the button will need to be pressed to scan. Step Action Hold the tube approximately 0.5 cm (0.2 in) from the scanning window, and t hen press the button on top of the reader. NOTE: This will prevent cross contamination and damage to the scanning window. The unit will beep once to indicate a successful read. Copyright © 2020, Brooks Automation, Inc.
Page 16
Brooks Automation FluidX Part Number: 281947 Rev. C The continuous scanning feature of the Scope USB reader can be turned ON by scanning the Continuous Scan ON Quick Setup Code on Page 11. If the continuous scan has been enabled, use the following instructions. Step Action Hold the tube approximately 0.5 cm (0.2 in) from the scanning window. NOTE: This will prevent cross contamination and damage to the scanning window.. The unit will beep once to indicate a successful read. Copyright © 2020, Brooks Automation, Inc.
Page 17: Reading A Linear Barcode
Brooks Automation Part Number: 281947 Rev. C 6. Reading a Linear Barcode The FluidX Scope USB also reads linear barcodes. Step Action Use the targeting light to aim the beam over the linear barcode and press the read button. T he unit will beep once to indicate a successful read. Copyright © 2020, Brooks Automation, Inc.
Page 18: Reader Feedback
7. Reader Feedback The FluidX Scope USB reader uses a combination of LEDs and audibles to indicate different scenarios. See the chart below for more information. Audio Scenario Feedback Feedback Green LED Successfully powers up 2 Beeps lights up Green LED Attempting to decode None light is off Successful decode and data Green LED 1 Beep transfer via cable lights up Configuration code successfully Green LED 2 Beeps decoded and processed lights up Configuration code successfully Green LED decoded but wasn’t 4 Beeps lights up successfully processed Copyright © 2020, Brooks Automation, Inc.
Page 19: Quick Setup Codes
Brooks Automation Part Number: 281947 Rev. C 8. Quick Setup Codes The FluidX Scope USB can be configured by scanning one of the codes from the table below. NOTE: The configuration change will take effect immediately and be saved to memory. Setup Action Setting Code Continuous Scan Off Default Continuous Scan On Optional Copyright © 2020, Brooks Automation, Inc.
Page 20
Brooks Automation FluidX Part Number: 281947 Rev. C Setup Action Setting Code Disable Alternative OS Default Enable Alternative OS Optional (MAC/Linux) Enabled reading of reversed codes (black on white or white on Default black). French Keyboard Mapping Optional German Keyboard Mapping Optional Japanese Keyboard Mapping Optional Mirroring On Default Copyright © 2020, Brooks Automation, Inc.
Page 21
Brooks Automation Part Number: 281947 Rev. C Setup Action Setting Code Technical Reader ID and Firmware Support STD Contrast Code (35% AGC) Optional Suffix - Enter Default Suffix - Tab Optional Universal Keyboard Mapping Default Copyright © 2020, Brooks Automation, Inc.
Page 22: Preventative Maintenance
Brooks Automation FluidX Part Number: 281947 Rev. C 9. Preventative Maintenance Periodically clean the scanning window with a moist, non-abrasive cloth to allow the best performance of the device. The following are safe to use for cleaning as needed: IPA (Isopropyl Alcohol) 70% alcohol Cleanroom wipes Mild detergents Copyright © 2020, Brooks Automation, Inc.
Page 23: Appendix A. Declaration Of Ce Conformity
Brooks Automation Part Number: 281947 Rev. C Appendix A. Declaration of CE Conformity Copyright © 2020, Brooks Automation, Inc.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL