Page 1
ABT 15ATEX4111 Installation, Operation and Maintenance Instructions Description The Abtech STR1 range of roadway lanterns are manufactured in Aluminium with a toughened glass window and silicone rubber gaskets providing sealing. The type of protection is Ex ec, Increased Safety. Application The luminaire is suitable for use in a Zone 2 area, gas and dust hazards, and reference should be made to the rating table below in respect of T rating and ambient temperature considerations.
Page 2
Supply voltage variation must not exceed ±6% and the luminaire should not be operated continuously beyond this limit. In any case the voltage variation must NEVER exceed ±10% as this will invalidate the certification and could lead to the product being unsafe. If in doubt, advice should be sought from Abtech technical department.
4. Gasket Replacement The unit gasket is one-piece silicone rubber and can only be obtained from Abtech. The old gasket should be removed and any traces of sealant cleaned off. The area where the gasket is situated should be clean and free from grease.
Page 4
IOM-STR1 2. Mounting options 3. Installation Abtech Ltd Newhall Road IOM-STR1 ABTQ210.docx t : +44 (0) 114 244 2424 Sheffield, S9 2QJ Page 4 of 6 f : +44 (0) 114 243 4312 United Kingdom e : sales@abtech.eu...
Page 5
IOM-STR1 Abtech Ltd Newhall Road IOM-STR1 ABTQ210.docx t : +44 (0) 114 244 2424 Sheffield, S9 2QJ Page 5 of 6 f : +44 (0) 114 243 4312 United Kingdom e : sales@abtech.eu...
Page 6
Lamps must not be incinerated. Lamps should be disposed of in accordance with local or national Abtech Ltd Newhall Road IOM-STR1 ABTQ210.docx t : +44 (0) 114 244 2424 Sheffield, S9 2QJ Page 6 of 6 f : +44 (0) 114 243 4312 United Kingdom e : sales@abtech.eu...