BIOGAS ANALYSER
User Manual
Biogas analyser ABE_1500
Ver 002

Advertisement

Table of Contents
loading

Summary of Contents for A.B.Energy ABE 1500

  • Page 1 ABE_1500 BIOGAS ANALYSER User Manual Biogas analyser ABE_1500 Ver 002...
  • Page 2 ABE_1500 The reproduction, transmission or use of this document Are AB Energy registered trademarks. or its contents is not permitted without express written All other product or system names are (registered) authority. Offenders will be liable for damages. All right trademarks of their respective owners and must be created by the patents or registration of a design are treated accordingly.
  • Page 3: Table Of Contents

    Warnings for trademan TABLE OF CONTENTS ABE_1500 ............8 KEYBOARD ............14 ANALOGIC INPUT ..........23 ANALOGIC INPUT CALIBRATION ....23 MEASURES CAMPS ......... 30 BATTERY RECHARGER........29 NUMERIC VISUALIZATION ......16 CPU DATA CONFIGURATION ......21 SCREEN ............14 STRUCTURE .............
  • Page 4: General Warnings

    Warnings for trademan Kind costumer, Before to use analyser, we maintain you to attentively read this manual! It contains warnings and important data, that, if you will observe, you will assure the instruments availability and some savings on costs. In this way, the use of this instrument will be easier and more durable. Note We advise you to contact our factory after to use the instrument for new application, for example in research and development.
  • Page 5 Warnings for trademan Attention With triangular advise, it means that can happen light wounds if don’t take the right precaution. Attention Without triangular advice. It means that can happen materials damages if don’t take the right precaution. Advise It means that can happen unexpected problems if you don’t observe correspondent advise.
  • Page 6 Warnings for trademan Guarantee’ s note The content of this manual don’t establish part of an agreement, promise or a juridical relation. All obligations by A.B. Energy S.r.l. resulted by buying and selling contract, witch contains also complete guarantee’s discipline. These contractual arrangements for guarantee are not extended or limited by exposition of this manual.
  • Page 7 Installations warnings Security warnings Warning Some this instrument’s parts are down dangerous voltage. After instrument’s insertion the case must be closed and connected to the ground. Warning The product mustn’t work in a place with risk of explosion. Mixture of explosive gas mustn’t be collected.
  • Page 8: Abe_1500

    Use instructions Principal characteristics  ABE_1500 analyser for methane (CH4), Carbon oxide (CO2), Carbon monoxide (CO), and oxygen in biogas. Measure camps 0-100% in volume for CH4, 0-100% in volume for CO2, 0-20000 ppm for CO, 0-25% in volume for O2. Oxygen sensor Utilized sensor (max_250) of electrochemical type;...
  • Page 9 Use instructions  ABE_550 Anemometer to read the gas flow inside pipe (diameter 16 mm) into the range 0.3 to 42 m/sec, from witch you can compute the gas flow into the pipe.  ABE_553 Software for Microsoft Windows 2000, XP for controller configuration and transfer dates compatibles Microsoft Excel.
  • Page 10: Supervision Software

    Use instructions Supervision software (ABE_553) Possibility of direct connector between analyser and PC for configuration, transfer or memorized data. The software is realized for Windows 2000 or XP, with “.net” technology. For more information of pack, make referred to software manual. Configuration software The software permits reading and configuration of function parameters of instrument and the visualization of reading.
  • Page 11 Use instructions Case (ABE_570) Plastic case for transport and protect the gas analyzer ABE_1500, it has transparent membrane for visualize the screen. Case ABE_570 Biogas analyser ABE_1500...
  • Page 12 Use instructions Sensor for H2S (ABE_580) Sensor for H2S 0 – 500 ppm Range Repond on time <30 sec. (H2S: 10 ppm) Gap on long period < 5% / anno Sensor life More than 2 years Operating Temperature -20°C / +50°C 15 –...
  • Page 13 Use instructions Sensor for NH3 (ABE_581) Sensor for NH3 0 – 1000 ppm Range Repond on time <120 sec. Gap on long period < 2% / mese Sensor life More than 2 years Operating Temperature -30°C / +50°C 15 – 90 % RH Operating Humidity Operating Pressure 1 atm +/- 10 %...
  • Page 14: Keyboard

    Use instructions Structure and characteristic Analyser  SCREEN LCD display has big dimension ¼ VGA (320*240 pixel) with inverse visual (lighter written), of blue colour. Best luminosity level. Possibility to change contrast. It permits to see at the same time all measures made by analyser in numerical form. In the main page you can change the display contrast with the up and down arrows.
  • Page 15 Use instructions POWER ON / OFF To turn on the analyzer press the secrete key below the word biotecnogas for more than 3 second. The following page will apper for 60 seconds during that the analyzer warm up the sensors and inizialise the system.
  • Page 16: Numeric Visualization

    Use instructions Numeric visualization It’s the main window on witch you can read all the sensor reading by system. More important values (Oxygen, Carbon Anhydride, and Methane) are showed with large characters for long distance easy reading. Main window On first line on the left it appear the ID of the well. On first line on the right are showed date and time, the internal watch work also when the analyser is off.
  • Page 17 Use instructions Function key Press F1 key to view the main screen. Press F2 key to edit the well ID. Press key from 0 to 9 to insert character and numbers. Press the key up and down to set the lower or upper case character. Push more times a numeric key from 0 to 9 untill the desiderated key is not show.
  • Page 18 Use instructions Press F4 key to go on the log page where you can see the data save on the instrument. In this page you can move between the memorize data using the left and right arrow. Press F5 key to go on the ID wells name page, where you can see the list of the well ID. You can chose the right well ID moving beween the ID using arrows, when the cursor in on the right name you can confirm it with enter key .
  • Page 19 Use instructions Insert well ID name In the main page press the key F2 to show the following page. Main page Write the ID name with the alfanumeric keyboard of the analyzer. Push enter key to confirm the ID name. Now in the main page the ID just write will be show in the ID name location.
  • Page 20: Data Salvage

    Use instructions Window password Password The key F3, move the visualization on password window. Pushing the right code (123456), pass directly in the first configuration window. Are present more or less configuration pages favourably of versions. When you are inside of configuration, you can move form one page to another page by tastes F1, F2, F3. For exit of configuration and come back on visualization pages, you must push taste ESC.
  • Page 21: Cpu Data Configuration

    Use instructions CPU data configuration System configuration  Device address: If more than one analyzer are connect on the same serial line each one must have a different address. (not use in ABE_1500 analyzer).  Time CPU ON: show (in minutes) for how time the CPU rest active without that is made any operation, in the end the analyser turn out itself automatically (0 for disability function).
  • Page 22 Use instructions When the calibration is performed the next calibration date will set 60 days in advance.  CH4 enabled: If set to one (ON) the metano sensor reading is enabled if set to 0 (OFF) the reading is disable. ...
  • Page 23: Analogic Input

    Use instructions Analogic input Card has 8 Analogic input managing by a high resolution converted (24 Bit) and a programmer gain between 1 and 64. Firsts 2 canals have input buffer realized with an amplifier with a high isolation and gain, six next canals have simple input buffer with negative input link to mass.
  • Page 24 Use instructions Analogic catalitic sensor input (push F3 key) By arrows “UP” “DOWN”, to place on value that on want modified, number disappear and it is changed by some dashes. Now, on write a new value and push “Enter”, new value is confirmed. The meaning of camps is the following: ...
  • Page 25 Use instructions Calibration analogic input example Oxygen from 0% to 5% For example for calibration of oxygen sensory: 1. Write: Channel 1 low value = 0 2. Connect nitrogen cylinder to instrument whit a flux of 5 litres, then wait at least 5 minutes for sensory stabilization.
  • Page 26 Use instructions Infrared sensory calibration For example for calibration of infrared sensory: 1. Write: Zero Value CH4 = 0 2. Write: Zero Value CO2 = 0 3. Write: Zero Value CO = 0 4. Connect nitrogen cylinder to instrument whit a flux of 5 litres, then wait at least 2 minutes for sensory stabilization.
  • Page 27 Use instructions Presure sensor calibration Connect the pipe to the plug and leave it free (not connect to anything, but in free air). From the main page push F3 key and go to the password page, write the password and then F2 key. With arrow down go to presure zero line, write 0 and press enter, confirm it with enter .
  • Page 28 Use instructions Well ID list If you push the F5 key in the main page the following screen will appear. Well ID name list In this page you can chose the well ID name. You can chose the right well ID moving beween the ID using arrows, when the cursor in on the right name you can confirm it with enter key .
  • Page 29: Battery Recharger

    Use instructions Battery recharger Battery rechargers The analyser is powered by a litium battery, this kind of battery is very powerfull, light and not present memory effect. With battery fully charge the analyser can work for till 10 hours before need a new recharge. To recharged the battery connect the recharger to the case tru the plug and push the red button on the recharger the yellow led will turn on and stay so till the bactery is fully recharged.
  • Page 30: Measures Camps

    Use instructions Technical note Operative temperature -5°C / 50°C Weight 3 Kg Dimension 206*197*70 mm Measures range Model Resolution Operative range 0 — 25% Volum. +/- 1% 0 — 100% Volum +/- 1.5% 0 — 100% Volum +/- 1.5% 0 — 20000 ppm +/- 1.5% 0 –...
  • Page 31 Use instructions Preservation works Warning Working with poison gas must be assured that in the working place cannot be concentration hurtful for health. In case of not appropriate gas lacing can be verify warning of accident due to poison gas, fuels or explosives. Attention Components and electrical modules inside this instrument must be protected against electric discharges.
  • Page 32 Use instructions Re-shipping Biogas analyser must be ship in the original packing. If you don’t have the original packing, the instrument must be wrapping up in a plastic film and then packing in a case dressed with anti-collision material. In case of maritime transport, the instrument must be warp up in a polystyrene film 0,02mm thick.
  • Page 33 Appendice Declaration of Conformity Attestato di Conformità The manufacturer Il Costruttore A.B.Energy S.r.L. Via Amendola 340 13836 COSSATO (BI) Italy declare under sole responsability that the products dichiara sotto la piena responsabilità che i prodotti model/modello: ABE_1500 type/tipo: Portable gas analyzer/Analizzatore di gas portatile...