Panacom PMS8232 User Manual
Panacom PMS8232 User Manual

Panacom PMS8232 User Manual

921,600 bps highspeed rs-232 multip-io card

Advertisement

Quick Links

PMS8232/PMS4232
921,600 bps Highspeed RS-232
Multip-IO Card
User's Guide
First Edition

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PMS8232 and is the answer not in the manual?

Questions and answers

Summary of Contents for Panacom PMS8232

  • Page 1 PMS8232/PMS4232 921,600 bps Highspeed RS-232 Multip-IO Card User’s Guide First Edition...
  • Page 2: Table Of Contents

    Contents ................ 1 NTRODUCTION ..................1 VERVIEW ’ ................ 1 NCLUDED ................2 ETUP ................2 LOCK ODES ‘D 1’ ....... 3 ATES AND IVISORS FOR THE MODE ............3 DDRESS AND SELECTION ................. 4 NSTALLATION ..........4 PERATING YSTEM NSTALLATION Windows 95/98/NT ..............
  • Page 3 Figures Figure 1 - Clocking Mode ‘Divide By 4’ ..........2 Figure 2 - Clocking Mode ‘Divide By 1’ ..........2 Figure 3 - Asynchronous Communications Bit Diagram...... 11 © 1999f PANACOM Technology, Incorporated. All rights reserved.
  • Page 4: Introduction

    RS-232 electrical interface, such as modems, data-entry terminals, and plotters. What’s Included The PMS8232 is shipped with the following items. If any of these items is missing or damaged, contact the supplier. •...
  • Page 5: Card Setup

    Card Setup Clock Modes The PMS8232 employs a unique clocking option that allows the end user to select from divide by 4 and divide by 1 clocking modes. This mode is selected at J2,J3. To select the Baud rates commonly associated with COM: ports (i.e. 2400, 4800, 9600, 19.2, … 115.2K Bps) place the jumper in the divide by 4 mode (silk-screen DIV4).
  • Page 6: Baud Rates And Divisors For The 'Div1' Mode

    921.6K bps Address and IRQ selection The PMS8232 is automatically assigned I/O addresses and IRQs by your motherboard BIOS. Only the I/O address may be modified by the user. Adding or removing other hardware may change the assignment of I/O addresses and IRQs.
  • Page 7: Installation

    System Installation The PMS8232 can be installed in any of the PCI expansion slots and contains a single jumper strap that must be set for proper operation. Please see the Card Setup section of the manual for information on this jumper.
  • Page 8: Technical Description

    Technical Description Technical Description The PMS8232 utilizes the 16C554 UART. This chip features programmable baud rate, data format, interrupt control and a 16-byte input and output FIFO, and is functionally 4 16C550 UARTs. The 16C654 UART is also available on this card, which has a 64-byte FIFO as opposed to the 16-byte FIFO available in the 16C554 and the 16C854 which has a 128-byte FIFO.
  • Page 9: Db-68 Connector Pin Assignments

    Technical Description DB-68 Connector Pin Assignments Port # PMS8232 / PMS4232 Page 6...
  • Page 10: Specifications

    295 mA Mean Time Between Failures (MTBF) Greater than 150,000 hours. (Calculated) Physical Dimensions Board length 5.300 inches (13.460 cm.) Board Height including Goldfingers 3.8 inches (9.652 cm.) Board Height excluding Goldfingers 3.475 inches (8.827 cm.) PMS8232 / PMS4232 Page 7...
  • Page 11: Appendixa - Troubleshooting

    Appendix A - Troubleshooting Appendix A - Troubleshooting A Serial Utility Diskette is supplied with the PANACOM Technology adapter and will be used in the troubleshooting procedures. By using this diskette and following these simple steps, most common problems can be eliminated without the need to call Technical Support.
  • Page 12: Appendixb - How T O Get Assistance

    When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics. PANACOM Technology maintains a Home page on the Internet. Our home page address is www.panacom.com.tw The latest software updates, and newest manuals are available via our FTP site that can be accessed from our home page.
  • Page 13: Appendixc - Electrical Interface

    +12 volts (usually +3 to +10 volts) represents a binary 0 (space) and -12 volts (-3 to -10 volts) denote a binary 1 (mark). The RS-232 and the EIA/TIA-574 specification define two types of interface circuits Data Terminal Equipment (DTE) and Data Circuit-Terminating Equipment (DCE). The PANACOM Technology Adapter is a DTE interface. PMS8232 / PMS4232 Page 10...
  • Page 14: Appendixd - Asynchronous Communications

    The data rate and communication parameters for asynchronous communications have to be the same at both the transmitting and receiving ends. The communication parameters are baud rate, parity, number of data bits per character, and stop bits (i.e. 9600,N,8,1). PMS8232 / PMS4232 Page 11...
  • Page 15: Appendixe - Silk -Screen

    Appendix E - Silk-Screen Appendix E - Silk-Screen PMS8232 / PMS4232 Page 12...
  • Page 16: Warranty

    Warranty Warranty PANACOM Techonoly, Inc. warrants this product to be in good working order for a period of one year from the date of purchase. Should this product fail to be in good working order at any time during this period, PANACOM Techonoly will, at it’s option, replace or repair it at no additional charge except as...