Instructions for installation and commissioning of the system ..............4 Installation under the sink 3/8" flexible connections (male delivery and female return): ......5 Installation in systems with 8 mm pipes: ....................7 MIOLED exploded view (spare parts) ......................7 Technical Datasheet (operative conditions) ....................8 Maintenance ............................... 9 Warranty Conditions ..........................
Introduction This manual applies to the below model: MIO LED The UV systems were made by S.I.T.A. s.r.l. Warning: This equipment requires regular maintenance to ensure the requirements of the drinking water treated and the maintenance of the improvements as stated by the manufacturer. These operating instructions contain important information for the operation and maintenance of the equipment.
Page 4
UV Light Danger: The light of ultra-violet lamps can cause serious burns to unprotected skin and eyes, therefore it is recommended not to connect it to the current tap without having before ensured the UV lamp in its housing and inserted the PVC cover. Pressure Danger: The UV chamber could be under water pressure.
The installation of the debacterization systems of the “LED” series must be carried out by specialized personnel strictly following the instructions stated below. The fittings supplied with the MIOLED are suitable for connection under the sink with 3/8” pipes. MIOLED includes the following parts:...
Installation under the sink 3/8" flexible connections (male delivery and female return): Warnings: Check that MIOLED is disconnected from the mains, that the raw water valve is closed and that the tap is open. Install MIOLED on the wall with the fisher supplied:...
Page 7
Connect the 3/8” female fitting of the delivery hose to the male fitting supplied. Connect the IN and OUT of MIOLED respecting the inlet and outlet described by the arrows on the label (below example with a flexible 3/8 "female tap): Open the inlet water supply and check that there are no water leaks in any part of the system.
Installation in systems with 8 mm pipes: Connect the IN and OUT of MIOLED respecting the input and output described on the label: MIOLED exploded view (spare parts) Item Code Description LD5.000 LED Disk + CABLE LD1QRZ MIOLED WINDOW LD1OR...
SITALED LD inside Material Stainless steel 304 Protection class IP 54 Replaceable Led Board UV BOX MIOLED MIOLED AL2 (coming soon) Material Black Polypropylene Dimensions 210 x 105 x 65 215 x 215 x 90 mm Protection class IP54 Ambient temperature range 5 –...
LED disk (code ): MIOLED turns on only when the water passes, optimizing the life of the LEDs themselves. Replace the led disk every 3000 hr of operation (8 years if it works on average 1 hr / day, 4 years if it works 2 hr / day ..)
7. Warranty Conditions WARRANTY CONDITIONS SITA works in compliance with ISO 9001-2015 quality procedures and subjects all equipment to accurate checks and tests. The SITA supplies and progressing are anyway guaranteed only in the limits of technical specifications and request and/or of the certificates and/or of the specific checks as agreed, for 24 months from the delivery date or 30 days from the purchase date, provided that eventual defects are stated as fixed by art.
EC DECLARATION OF CONFORMITY The undersigned hereby declares, under full responsibility, that the unit: UV DISINFECTION SYSTEM LED SERIES MOD. MIOLED IS ACCORDING TO the provisions of Community Directives and Regulations: • 2014/35 / EU (low voltage directive) • 2014/30 / UE (electromagnetic compatibility) •...