TEREN OS Manual

TEREN OS Manual

Occupancy sensor/ detector

Advertisement

OS Occupancy Sensor/ Detector Manual
OS-C
Applications & Features
Suitable for passage way, corridor, toilet, basement, garage
and other public places, such as lighting, exhaust fan and
other automatic switch control. OS-W is wall-mounted type,
OS-C is ceiling-mounted type
Based on PIR infrared sensor and photosensitive sensor
combination technology, high sensitivity, strong reliability,
safe and convenient, intelligent energy saving
Fully automatic induction, switch on for occupancy, delay
off for vacancy automatically
Application of photosensitive automatic control, no
induction in day or high illumination circumstance,
illumination can be adjusted
Automatic random delay, switch on for occupancy and
continue to turn on if detecting activity, and delay off until
detecting no activity
Temperature compensation and anti RFI/EMI
Light and state of art housing, easy installation and using

Specifications

Sensor: PIR infrared sensor, photo resistance sensor
Power supply: 20~28VDC
Output: SPST, 10A resistive / 4A inductive, 30VDC/250VA
5
Life circle: 10
times
Light control range (adjustable): OS-W: Night/Full day
(default night )
OS-C: 5~500Lux± 20% (default 5Lux± 20%)
Delay closing time (adjustable): OS-W:15s~20min(default
15s)
OS-C: 16~350s(default 16s± 30%)

Connection

V-
V+
COM
POWER SUPPLY
24V DC
OS Occupancy Sensor/ Detector
NO
OS-W
Detect area: cone angle 140° ,distance 5-8m(<=24° ) ,shown
as below,
Mount Height: wall mount height is about 1.5m, and ceiling
mount height is about 2~4m
Working environment: -20~50° C, 0~95%RH(Non-cond.)
Storage temperature: -30~70° C
Housing: fireproof ABS(except Fresnel lenses), IP30
Weight: OS-C:120g,OS-W:110g
Approval: CQC
Detect area diagram:

Models

OS-W
Wall mount occupancy sensor / detector
Models
OS-C
Ceiling mount occupancy sensor / detector
Edition:A/1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TEREN OS

  • Page 1 Mount Height: wall mount height is about 1.5m, and ceiling and other public places, such as lighting, exhaust fan and mount height is about 2~4m other automatic switch control. OS-W is wall-mounted type, Working environment: -20~50° C, 0~95%RH(Non-cond.) OS-C is ceiling-mounted type Storage temperature: -30~70°...
  • Page 2 OS Occupancy Sensor/ Detector Manual Edition:A/1 Settings Power OFF before setting the parameters, and do not operate with power on. OS-C: Delay setting: The delay potentiometer is factory default at the clockwise end (about 16 seconds), rotate counterclockwise to increase the delay time, counterclockwise 180 degrees means to increase about 360 seconds.

This manual is also suitable for:

Os-cOs-w