Page 1
Product Bulletin # TDS-199 Rev 2 Handler Lock Sensor Improvement Canrig has discontinued the use of the current handler lock sensor assembly (AY10484-X) which is used on 1250AC and 1275AC top drives. The handler lock sensor has been replaced with a new handler lock sensor with a simplified design and improved securement.
Page 3
Model: See affected models Sep. 29, 2021 Serial #: N/A Procedure Follow steps below to remove existing handler lock sensor and install new handler lock sensor. Remove Existing Handler Lock Sensor Assembly 1. Ensure handler lock is engaged and in the lock position before beginning. 2.
Page 4
2. Install the handler lock sensor bracket with two 1/2-13UNC x 1" hex head bolts and two 1/2" Nord-Lock washers. See Figure 3. 3. Torque bolts to 99 ft-lbs per Canrig Engineering Specification ENG 725. Mounting hardware Figure 3: Mounting Bracket Installation 4.
Page 5
Model: See affected models Sep. 29, 2021 Serial #: N/A 6. Align sensor to sensor target. Adjust the sensor target to a minimum gap of 0.03" and a maximum gap of 0.048". Do not adjust the sensor. See Figure 5. Sensor .03 [1] MIN GAP .048 [1.2] MAX GAP...
Page 6
Model: See affected models Sep. 29, 2021 Serial #: N/A 11. To connect the new sensor and cable, refer to Subsection 6E of the Top Drive Parts Manual. This section contains the schematics that show the correct wiring of the sensor. Contact RIGLINE 24/7™...