EVOLUTION MEASUREMENT EvoScann CANDI ELE-CANDI-CANDI01 Product User Manual

Advertisement

Quick Links

EvoScann® CANDI
Evolution Measurement Ltd
CANbus to USB Converter
Revision History:
Issue: 1 Revision: 0
Issue: 1 Revision: 1
©Evolution Measurement Ltd 2021. All rights reserved
Product User Guide
EvoScann® CANDI
(P# ELE-CANDI-CANDI01)
P a g e
First issued – August 2020
Updated Logging Information / GUI Info
Doc.No: M-90223 Iss.1 Rev 1
| 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EvoScann CANDI ELE-CANDI-CANDI01 and is the answer not in the manual?

Questions and answers

Summary of Contents for EVOLUTION MEASUREMENT EvoScann CANDI ELE-CANDI-CANDI01

  • Page 1 CANbus to USB Converter (P# ELE-CANDI-CANDI01) Revision History: Issue: 1 Revision: 0 First issued – August 2020 Issue: 1 Revision: 1 Updated Logging Information / GUI Info ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e...
  • Page 2: Table Of Contents

    Electrical Connection Operation……………………..………………………………………………….…..8 Maintenance……………………………………………..…………………………..8 General Information Safety Information Fault finding Repair and Recalibration Storage and Disposal…………………..……………………………………..……9 Storage Disposal GUI - Graphical User Interface Use………………………………………………10 ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e...
  • Page 3: Introduction

    Electrical connection can be made to the EvoScann® P-Series Pressure Scanner either via the green 4-way terminal block or fixed ASX Circular Connector. Note, only one scanner should be attached at a time, using only one connection method. ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e...
  • Page 4: Specification

    PEAK-System Installation Package (Supplied) National Instruments™ Runtime Engine (Supplied) Software: Evolution Measurement Node Tool (P-Series Specific) Dimensions: Outer case: 85 x 75 x 20 mm ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e...
  • Page 5 EvoScann® CANDI Product Outline Dimensions EvoScann® CANDI CANbus to USB Converter ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e...
  • Page 6: Installation & Use

    Refer to the supplied USB Drive for files and Readme.txt regarding installation of the Drivers and GUI version before any connection to the EvoScann® P-Series Pressure Scanner is attempted. ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1...
  • Page 7: Electrical Connection

    Electrical Cable Identification Cable Identification YELLOW CANH GREEN CANL SUPPLY (VSUP) BLACK (Note: Check direction indication marked on the one fitted to your CANDI) ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e...
  • Page 8: Operation

    Below is a screenshot of a typical display from the EvoScann® GUI, with EvoScann® (P-Series P8-A for information). Refer to Section 7 for use. ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e...
  • Page 9: Maintenance

    Field repair is not possible with EvoScann® CANDI. All repairs must be carried out by Evolution Measurement Ltd. To ensure optimum service and performance, return to Evolution Measurement Ltd. See contact us page. ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1...
  • Page 10: Storage And Disposal

    Disposal At end of life, dispose of EvoScann® CANDI in full accordance with all local procedures and practices, or return the unit to Evolution Measurement Ltd for disposal. Do not incinerate as the product may emit noxious fumes. ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1...
  • Page 11: Gui - Graphical User Interface Use

    Length – 8 Byte / 7 Byte (8 Byte Default) Range – Selected Range Pressures – Shows live channel pressures in selected pressure range mode ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e...
  • Page 12 BAUD – Allows rate to be set – Sensor ID Number (>=Ver 10 Firmware Required) nBYTE – 8 Byte / 7 Byte (8 Byte Default) ID – User configurable (Hexadecimal) PCAN – Period Setting Options ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e | 12...
  • Page 13 Press the file icon, the route path can now be set for the log file. Click Sensor Number to create individual log file… Record – Starts the current log file / Logging - Stops the current log file. ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e...
  • Page 14 Evolution Measurement Ltd 7 Regents Court, South Way, Walworth Business Park, Andover, Hampshire SP10 5NX, UK Telephone: +44 (0) 1264 316470 Email: enquiries@evolutionmeasurement.com www.evolutionmeasurement.com ©Evolution Measurement Ltd 2021. All rights reserved Doc.No: M-90223 Iss.1 Rev 1 P a g e | 14...