TransTank AquaModule Operator's Handbook Manual

TransTank AquaModule Operator's Handbook Manual

Water cartage unit

Advertisement

Quick Links

OPERATOR'S
HANDBOOK
w w w . t t i . c o m . a u
AquaModule
AquaModule
Water Cartage Unit
Manufacturer of "The Safest Tanks in Motion"

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AquaModule and is the answer not in the manual?

Questions and answers

Summary of Contents for TransTank AquaModule

  • Page 1 OPERATOR’S HANDBOOK w w w . t t i . c o m . a u AquaModule AquaModule ™ ™ Water Cartage Unit Manufacturer of “The Safest Tanks in Motion”...
  • Page 2: Table Of Contents

    TTi’s AquaModule HandBook ™ Table of Contents Introduction Safety General Specifications General Information Description Overview Maintenance Troubleshooting Risk Assesment Mounting Instructions for Chassis Frame Fish Plate Mounting Instructions Spring Mounting Instruction (Optional) Warranty Policy Warranty Limitations Warranty Registration Card www.tti.com.au...
  • Page 3: Introduction

    TTi’s AquaModule HandBook ™ Introduction Please read your operators handbook carefully before commissioning and using your Storm unit. Keep your handbook in a safe place. Congratulations on your purchase of a Trans Tank International Storm Dust Suppression Unit! The Trans Tank International Dust Suppression System is a truck-mounted tank and water dispenser system designed to suppress dust on unmade roads, construction sites and other places where dust needs to be controlled.
  • Page 4: Safety

    TTi’s AquaModule HandBook ™ Safety General The following pages outline important safety information. As safety is a priority at TTI we have included some basic safety requirements. These safety and warning instructions MUST be followed to ensure the safe operation of your equipment.
  • Page 5 TTi’s AquaModule HandBook ™ Personal Protective Equipment [PPE] Always wear close fitting clothing and safety equipment designed for the job. Exposure to loud noise over an extended period can cause impairment or loss of hearing. Be active in the conservation of your hearing and wear appropriate hearing protection at all times.
  • Page 6: Specifications

    TTi’s AquaModule HandBook ™ Specifications TANK UV resistant polyethylene tank c/w LiquidLocker™ baffling system STANDARD LiquicLocker™ Baffle Safety System EQUIPMENT Multi-Purpose Spring Rewind Hose Reel Rotating Beacon Pressure Regulator Bottom Fill Kit Sight Level Tube OPTIONS 1,5” and 3” spray heads - solenoid operated 3”...
  • Page 7: General Information

    TTi’s AquaModule HandBook ™ General Information Description Overview The unit is designed to carry and distribute water using a hydraulic powered water pump & various water dispensing systems. A number of features incorporated in the design are intended to ensure safe operation but it is the owner/operator’s responsibility to ensure that this equipment is mounted securely and operated safely at all times.
  • Page 8 TTi’s AquaModule HandBook ™ Water Dispensing Operation (In-Cab Controlled) The Storm™ Water Truck is controlled from the vehicle cab using the in-cab control box which allows the oper ator or driver to control the pump and valves while in motion.
  • Page 9 TTi’s AquaModule HandBook ™ Water Dispensing Operation (Rear of Truck Operation) Hydrant Fill Discharge Suction Suction Hose Reel Tank Valve StandPipe Valve Valve Port Valve 20m Hose Reel The 20 metre hose reel is fitted with an adjustable nozzle, which permits control from off through to jet mist spray.
  • Page 10 TTi’s AquaModule HandBook ™ Filling the Tank Hydrant Fill Operation Attach the hydrant supply hose to the hydrant port. Open hydrant slowly to ensure correct operation. Water will flow through top hydrant filling system on unit. When operation is complete, disconnect hose.
  • Page 11: Maintenance

    TTi’s AquaModule HandBook ™ Maintenance • Periodically [at least annually] check all hoses, nozzles and fittings for any sign of wear. Replace any parts which are worn or defective • If hose reel has not been used for any length of time. Unwind it fully to check that hose is in good order, pressurise the line &...
  • Page 12: Troubleshooting

    TTi’s AquaModule HandBook ™ Troubleshooting P R O B L E M P O S S I B L E CAU S E S O LU T I O N » Check battery state-of- charge » Dead battery » Replace fusible link »...
  • Page 13: Risk Assesment

    TTi’s AquaModule HandBook ™ Risk Assesment Product Information Risk Assessment Sheet TTi - Storm Unit TASK HAZARDS RISK CONTROL MEASURES Concentrate on task; follow safe manual handling techniq ues: • Don’t lif t on your own if > 20kg, bend knees &...
  • Page 14: Mounting Instructions For Chassis Frame

    TTi’s AquaModule HandBook ™ Mounting Instructions for Chassis Frame Mounting instructions for Chassis Frame Required Components Required Components: o 4 - 5 x fishplate pairs • 4 - 5 x Fishplate Pairs Mounting instructions for Chassis Frame o 2 x spring mount (optional) •...
  • Page 15: Spring Mounting Instruction (Optional)

    TTi’s AquaModule revent flexing. See HandBook ™ Top - mounting to the subframe Top – mounting to the subframe Bottom - mounting to the truck Bottom – mounting to the truck chassis (body) chassis (body)
  • Page 16: Warranty Policy

    TTi’s AquaModule HandBook ™ Warranty Policy 1. Warranty Policy TTI will, at its option, repair or replace, without charge, any part covered by this warranty which is found to be defective in material and/or workmanship within one (1) year* after date of sale to the original retail purchaser unless the product is used for rental purposes, in which case this warranty is limited to ninety (90) days.
  • Page 17: Warranty Limitations

    TTi’s AquaModule HandBook ™ Warranty Limitations a] There is no other express warranty. Any warranty that may be implied from this purchase including merchantibility and finess for a particular purpose is hereby limited to the duration of this warranty and to the extent permitted by law. Any and all implied warranties are excluded.
  • Page 18: Warranty Registration Card

    TTi’s AquaModule HandBook ™ Warranty Registration Card To validate your warranty, please complete registration on-line at: www.tti.com.au/warranty-registration Alternatively if you are unable to register on-line fill in all the details below, copy and email to warranty@tti.com.au or post to the address on the back cover.
  • Page 19 Storm ™ Test and Quality Checklist w w w . t t i . c o m . a u Date: Job No: Tester: Engine No: Tank No: Item Comp Notes Hydraulic Oil Level Tank Pins Bar, Wedges, Spacer and Fasteners are Tighted No Air and Water Leak Detected - Air Pressure set between 85 to 100 PSI...
  • Page 20 w w w. t t i . c o m . a u 1800 816 277 sal es@t ti.co m .au PO Box 137, N a t ha l i a , V I C , 3 6 3 8 M ur ra y Valley Hw y, N a t h a l i a , VI C 3 63 8...

Table of Contents