  • Page 2: Contents Of The Turn All System

    CONTENTS OF THE ABOUT USING AND TURN ALL SYSTEM INSTALLING ® THE SYSTEM 1 piece. Turn All Pump 3C This operator’s manual provides ® some important information 1 piece. Power cord for Turn All Pump about working with the Turn 1 piece.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Contents of the Turn All system ....................2 ® About using and installing the system ..................2 About positioning patients and the Turn All system ............4 ® Turn All system function ......................5 ® Installation of the Turn All system (including correct positioning under the ®...
  • Page 4: About Positioning Patients And The Turn All ® System

    ABOUT POSITIONING PATIENTS AND THE TURN ALL SYSTEM ® Pressure injuries are localised areas of skin and/ change of direction. or underlying tissue that have been damaged by The automated operation of the Turn All System constant exposure to direct pressure or pressure significantly reduces the pressure and work load in combination with shear and/or friction on both ‘in home’...
  • Page 5: Turn All ® System Function

    TURN ALL ® SYSTEM FUNCTION Dynamic mode - Automatic The illustration below shows the sequence of the automated positioning in the Turn All system. ® The Turn All system is an automated lateral ® turning system designed to deliver consistent and effective pressure care for vulnerable immobile patients with pre-existing pressure injuries, as well as providing protection for...
  • Page 6: Installation Of The Turn All ® System (Including Correct Positioning Under The Patient's Mattress)

    INSTALLATION OF THE TURN ALL SYSTEM ® Correct positioning of the Turn All system ® Figure 1 on a bed Remove the mattress from the bed Mattress (Figure 1). Place the Turn All system (A) on the bed ® base, orienting the system so that the hose connection (B) is at the foot end of the bed (Figure 1.2).
  • Page 7: Important Information! Regarding The Hose Connection

    Important information! Regarding the To commence turning the patient on the hose connection right side of the bed, seen from the foot end, the hose connection is inserted into The orientation of the hose connection (B) the air hose socket with the letter “R” determines which side of the mattress is adjacent to the words “Start side”...
  • Page 8: Starting And Adjusting The Turn All ® System

    STARTING AND ADJUSTING THE TURN ALL SYSTEM ® Insert the power cord’s female IEC C13 followed by 15 minutes in the supine plug into the corresponding male IEC C13 position. The process is then repeated on socket on the side of the pump (Figure 7) the opposite side, followed by another 15 Then plug the other end of the power cord minute rest period in the supine position.
  • Page 9: Using The Turn All ® System For Static Side-Lying

    USING THE TURN ALL SYSTEM ® FOR STATIC SIDE-LYING If the Turn All system is to be used as an ® inclined static support cushion, it is essential that the air hose connector be inserted the right way round, when plugged into the Turn All Pump 3C, to ensure the mattress begins to rise on the correct side.
  • Page 10: Indications And Contraindications

    INDICATIONS AND CONTRAINDICATIONS Indications / Purpose The Turn All system is suitable and ® recommended: Pressure injury prevention and treatment. Existing pressure injuries and/or the risk of • For people with moderate to high developing them. risk of developing pressure injuries, according to the Braden scale The Turn All system can operate on beds...
  • Page 11: Allowed Uses / Locations

    Contraindications / Risks of use / The Allowed uses / locations product cannot be used The Turn All system is designed to be used ® The Turn All system cannot be used for on standard care beds with a removable ®...
  • Page 12: Safety

    SAFETY This section provides an overview of the Ensure the pump and power cord are important safety aspects, for optimum positioned in such a way as to eliminate, protection of patients and caregivers, as as much as possible, unintentional well as safe and trouble-free use of the disconnection from power source.
  • Page 13: Warranty And Liability Provisions

    WARRANTY AND LIABILITY PROVISIONS Elevation of the care bed When used correctly, Levabo ApS gives a 24-month guarantee from the invoice date. The system is still able to operate effectively on a healthcare bed with During this period, faulty parts will be electric profiling functions, when both repaired or replaced, free of charge, if backrest and knee break are elevated.
  • Page 14: Cleaning And Disinfection

    CLEANING AND DISINFECTING Cleaning the Turn All system If the Turn All system has been ® ® contaminated by body fluids, the following Turn All Cover Detach the blue PU coated ® method of cleaning is recommended. two way stretch fabric Cover Upper from the 600D Black Dacron Cover Base, then In addition to machine washing the Turn All remove the Multi Patient Inner Lifting Cells.
  • Page 15 If the Turn All system needs to be cleaned, ® open the Cover zipper to separate the Cover Upper (J) from the Cover Base and remove the Multi Patient Inner Lifting Cells (H). See Figure 1. Pull the connection tubes (B), for the Multi Patient Inner Lifting Cells, through access sleeve in the Cover Upper (Figures 1 &...
  • Page 16: Notification Of Accidental Events

    NOTIFICATION TECHNICAL DATA OF ACCIDENTAL EVENTS Any product malfunction that has Dimensions (L x W x H) caused personal injury must be notified Cover ..........200 x 85 x 15cm immediately to the appropriate statutory Lifting mattress ........200 x 85cm authority and Levabo ApS.
  • Page 17: Approvals, Standards And Regulations

    APPROVALS, STANDARDS AND REGULATIONS Cover upper part Pump Medical BI ELASTIC PES PU Tested and approved in accordance to: Antibacterial and Antifungal: IEC 60601-1: 2006 +A1: 2013: General ISO 22196:2011 - PASS Requirements for Basic Safety and Essential Performance. Flammability BS 7175 ignition source 5 Pre-treatment: None Tested and approved in accordance to: Method of Test: BS 7175: 1989 (2013)
  • Page 18: Turn All Product Range

    TURN ALL PRODUCT RANGE SYSTEMS Product Name Product Code Size Description Turn All Multi-Patient System - includes inflatable lifting cells, combination Cover with removable 2 way stretch, Turn All Multi-Patient 200cm L x 85cm vapour permeable and water System w/TPU Base and PCLV-70128 150kg W x 15cm H...
  • Page 19: Explanation Of Symbols On The Packaging

    EXPLANATION OF SYMBOLS ON THE PACKAGING Read the user guide Expiration Date Conformité Européenne Material in the Production number Single-patient device packaging Manufacturer Date of manufacture Product number NOTES Product Turn All is an active medical product in ® accordance with: Declaration of Conformity (CE) EU Regulatory MDR (EU) 2017/745, Medical The company Levabo ApS, Sverigesvej...