Measurements And Adjustments; Adjustment - Panasonic TH-P50ST30D Service Manual

Hide thumbs Also See for TH-P50ST30D:
Table of Contents

Advertisement

10 Measurements and Adjustments

10.1. Adjustment

10.1.1. Vsus selection
Caution:
When Plasma panel or A-board is replaced, Vsus should be set to LOW.
Procedure
1. Go into main item [VSUS] in Service Mode. LOW will be displayed.
2. Press [OK] button to go to TEST stage.
White pattern without On-Screen Display will be displayed during TEST and CONF stage. Press [5] button to display the
On-Screen Display.
3. In LOW setting
If no several dead pixel is visible remarkably in white pattern, press [3] button to go to CONF stage.
4. Press [OK] button in CONF stage to store LOW.
5. Exit Service Mode by pressing [Power] button.
29

Advertisement

Table of Contents
loading

Table of Contents