May 19, 2025

Why does my ice maker keep going to E-3 mode? Also can you send me a picture of how the water pump should be placed inside the water tank?

1 comments:
Mr. Anderson
May 23, 2025

The RovaEarth CIM-480F ice maker goes into E3 mode when the ice is too thick or too thin, causing a de-icing failure. Adjust the ice size using the +/- buttons to correct the issue.

This answer is automatically generated

RIP
July 27, 2025

I CAN NOT CLEAR THE E 3 CODE . THE SIZE OF THE CUBE DOES NOT SEEM TO CHANGE

Subscribe to Our Youtube Channel

Summary of Contents for RovaEarth CIM-480F

  • Page 1 RovaE a r th USER MANUAL COMMERCIAL ICE MAKER Models CIM-480F, CIM-720F, CIM-960F...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS BEFORE STARTING PART NUMBERS INSTALLATION HOW TO USE TROUBLESHOOTING MAINTENANCE SPECIFICATIONS WARRANT Y...
  • Page 3: Before Starting

    BEFORE STARTING PART NUMBERS EXTERIOR • To prevent any internal damage or malfunctions, keep refrigeration unit upright during transportation and installation. Keep the unit upright for 24 hours before beginning use. • Inspect the unit before installing. Do not use unit with any visible damage or warranty may be waived.
  • Page 4: Installation

    INSTALLATION BOT TLED WATER WATER LINE INSTALLATION INSTALLATION WATER LINE INLET PIPE VALVE WATER FILTER FILTER HOLDER UNIT WATER INLET PIPE DRAIN PIPE DRAIN PIPE 1. Tilt the unit slightly to install the four feet. 1. Tilt the unit slightly to install the four feet. 2.
  • Page 5: How To Use

    HOW TO USE • Once a start/stop timer has been set, the indicator light will turn green. TURNING THE LIGHT ON/OFF • Press the light button to turn on the interior lighting. The green indicator light will appear and the interior lights will be present.
  • Page 6: Troubleshooting

    TROUBLESHOOTING ERROR CAUSE SOLUTION ERROR CAUSE SOLUTION E1, E2 Temperature probe experi- Check the connection of the insert. Unit has stopped No water or not enough Check the water supply or encing an open circuit working and the + water refill the water supply.
  • Page 7 MAINTENANCE SPECIFICATIONS • Clean the unit thoroughly before use and every 360 MODEL CIM-480F CIM-720F CIM-960F hours to maintain proper function and cleanliness. 115V 115V 115V RATED VOLTAGE • Unplug the unit before cleaning. RATED FREQUENCY 60Hz 60Hz 60Hz •...