Table of Contents Medical Disclaim er……………………………………………………………………………03 I nt ended Use………………………………………………………………………………..…03 About Blood Pressure………………………………………………………………………04 Measur em en t Met h od……………………………………………………………………0 6 Accu r a c y………………. …………………………………………………………………0 7 Pr e c a u t i o n s …………………………………………………………………………. 0 8 Device Overview……………………………………………………………………………….11 Sy m bol Definit ions………………………………………………………………………….13 Feat ures……………………………………………………………………………………………14...
HL858DM is equipped wit h an Advanced I HB det ect ion feat ure t o collect and analyze pulses. I f t he specific irregular heart beat s are det ect ed and it m ay affect blood pressur e reading w it h deviat ion, t he device will give t he user a warning signal.
About Blood Pressure A. What is blood pressur e? Blood pressure is t he m easurem ent of t he force of blood pushing against t he walls of t he art eries. Ar t erial blood pressure is const ant ly fluct uat ing dur ing t he course of t he cardiac cycle. The highest pressure in t he cycle is called t he syst olic blood pr essure, and represent s t he pressure in t he art ery when t he heart is beat ing.
Page 5
About Blood Pressure A. W H O blood pr essur e cla ssifica t ions: St andards for assessm ent of high or low blood pressure wit hout regard t o age, have been est ablished by t he World Healt h Organizat ion ( WHO) , as shown in t he chart .
Measurement Method HL858DM Aut om at ic Upper Arm Blood Pressure Monit or m easures blood pressure and heart rat e by oscillom et ric m et hod, m eaning t he fluct uat ions in pressure are m easured. Once t he cuff is wrapped around your upper arm , j ust t urn on t he m onit or and inflat ion aut om at ically st art s.
Accuracy HL858DM Aut om at ic Upper Arm Blood Pressure Monit or has been clinically t est ed against scient ific device called m ercury sphygm om anom et er, considered t he gold st andard in blood pressure m easurem ent .
Precautions Do not use t his m anual and product as a subst it ut e for advice, diagnosing or t reat ing a healt h problem or prescribing any m edicat ion by your doct or. I f you have a m edical problem , prom pt ly consult your healt hcare provider.
Page 9
Precautions For t hose who have had a m ast ect om y or lym ph node clearance, it is recom m ended t o t ake a m easurem ent on t he unaffect ed side. When used am ong m edical elect ronic equipm ent on t he sam e lim b, pressurizat ion of t he cuff m ay cause t em porarily m alfunct ion t o ot her devices.
Page 10
Precautions ! * At t e nt ion Do not use t he device on infant s, children, or t hose who cannot express t heir own int ent ion. To avoid accident al st rangulat ion, keep t his product away from children and do not drape t ube around neck.
Device Overview Part nam es and product com ponent s DI SPLAY BP Cat egory Arm Cuff hole I ndicat or BAR TI ME BUTTON DC JACK START / STOP BUTTON DOWN BUTTON 6V 1A AC/ DC Adapt er ( Opt ional) LCD DI SPLAY MEMORY...
Page 12
Device Overview Unit display Hour : Minut e ( Also represent s YEAR in Set t ing Mode) Heart Rat e Mont h / Dat e Syst olic Pressure Mem ory Average Blood Pressure Unit Low Bat t ery Sym bol BP Cat egory I ndicat or Mem ory Record Num ber Pulse Sym bol...
Symbol Definitions SYM BOLS D e finit ion s This sym bol appears when t he bat t ery power is excessively low or t he polarit y reverses. We suggest you replace all bat t eries wit h new ones, and Low Bat t ery Sym bol m ake sure t he + / - polarit ies are properly posit ioned.
Features BP Cat e gor y I ndic at or This dev ice is equipped wit h BP Cat egory I ndicat or which classifies your blood pressure m easurem ent s int o six st ages ( Opt im al t o Severe hypert ension) as shown in below chart : St ages of Blood Syst olic...
Page 15
Features For adult s 18 and older who are not on m edicine for high blood pressure, are not having a short - t erm serious illness, and do not have ot her condit ions, such as diabet es and kidney disease. To det erm ine cat egory of risk when syst olic and diast olic readings fall int o t wo areas, use t he higher of t he t wo num bers for classificat ion.
Page 16
Features Adva nc e d I rre gula r H e a r t be at De t e c t or This device equipped an Advanced I HB det ect ion feat ure. The sym bol Advanced I HB appears on screen indicat es t he specific heart beat irregularit y was det ect ed during m easurem ent .
Installing Batteries When LOW BATTERY SYMBOL appears on t he display, or no react ion t oward operat ion, please change bat t eries. Replace all worn- out bat t eries wit h new ones and do not m ix new and used bat t eries.
Page 18
Using the AC Adapter This m onit or is designed for operat ion wit h bat t eries or an AC/ DC adapt er. Please use only a com pat ible AC/ DC adapt er wit h required volt age and current as indicat ed in t his m anual.
Applying the Cuff Wrap t he cuff on a bare arm or over t hin clot hing. Thick clot hing or a rolled up sleeve w ill cause inaccurat e blood pressure m easurem ent s. Press your brachial art ery approxim at ely 1 inch ( 2 ~ 3 cm ) above t he elbow on t he inside of your left arm t o det erm ine where your st r ongest pulse is.
Measurement Procedure Swit ch on t he Monit or A. Put in 4 AAA “ LR03” ( 1.5V) alkaline bat t eries. B. Press START/ STOP but t on t o swit ch on t he m onit or. The m onit or will aut om at ically t urn t o st andby m ode.
Page 21
Measurement Procedure B. Wit h t he cuff wrapped around your upper arm , and place t he finger gent ly on t he Adva nce d I H B det ect ion area, t hen m ake sure t he finger place at t he correct posit ion, press but t on t o st art m easurem ent .
Page 22
Measurement Procedure LCD screen displays your syst olic rat e, diast olic rat e, pulse, Risk Cat egory I ndicat or Bar, Advanced I HB Det ect ion feat ure- relat ed sym bol and I rregular Heart beat Det ect or sym bol ( if any) wit h dat e and t im e for 1 m inut e.
Memory Function St oring dat a Aft er each m easurem ent , t he syst olic and diast olic pressure, heart rat e, pulse, Risk Cat egory I ndicat or Bar, Adva nce d I H B Det ect ion feat ure- relat ed sym bol and I rregular Heart beat Det ect or sym bol ( if any) wit h dat e and t im e will be aut om at ically st ored.
Storage and Maintenance General Use Do not in any way t wist t he cuff. Do not press but t on if t he cuff is not wrapped around your upper arm . Do not drop t he product and avoid any st rong im pact s. ...
Bluet oot h feat ure ON When connect ion est ablished, HL858DM will light Bluet oot h indicat or if it ’s in a reachable range ( no m ore t han 10 m et ers) w it h each ot her.
Page 26
* N ot e ! HL858DM is subj ect t o and com plies wit h elect rom agnet ic com pat ibilit y ( EMC) st andard of I EC 60601- 1- 2, EN 301 489- 1, EN 301 489- 17, EN 300 328 and U.S.
Troubleshooting I N D I CATI ON / SYM BOLS/ SYM PTOM S CON D I TI ON S/ CAUSES CORRECTI ON Unit does not t urn on when Replace t hem wit h 4 Worn- out bat t eries. new AAA ( LR03) but t on is pushed.
Limited Warranty W a r r an t y For Tw o Ye a r s fr om t he m a nu fa ct u r in g da t e Please not e t hat t his warrant y does not cover dam age caused by m isuse or abuse;...
Specifications Model Num ber HL858DM Measurem ent Met hod Oscillom et ric Rat ed Range of Cuff 0 ~ 300 m m Hg Pressure Rat ed Range of 40 ~ 280 m m Hg Det erm inat ion Measurem ent Range of...
Note Ex pla n a t ion of sym bols : Sym bol Ex pla na t ion H e a lt h & Life I n form a t ion Refer t o inst ruct ion m anual/ booklet TYPE BF Applied Part Warning: Port able RF com m unicat ions equipm ent ( including...
Page 31
“Changes or m odificat ions not expressly approved by t he m anufact urer could void t he user’s aut horit y t o operat e t he equipm ent ” HL858DM essent ial perform ance per I EC 80601- 2- 30 addit ional essent ial perform ance requirem ent s: ...
Appendix Guida nce a nd m a nufa ct ur e r ’s de cla r a t ion – e le ct r om a gne t ic e m issions The device is int ended for use in t he elect rom agnet ic environm ent s list ed below, and should only be used in such environm ent s: Em ission s t e st Com plia n ce...
Page 33
Appendix Guida nce a nd m a nufa ct ur e r ’s de cla r a t ion – e le ct r om a gne t ic im m u nit y The device is int ended for use in t he elect rom agnet ic environm ent s list ed below, and should only be used in such environm ent s: Com plia nce Ele ct r om a gne t ic e nv ir onm e nt –...
Page 34
Appendix Test specificat ions for enclosure port im m unit y t o RF w ireless com m unicat ions equipm ent . I M M UN I TY Te st fr e qu e n cy M odu la t ion TEST LEVEL ( M H z) ( V/ m )
Blood Pressure Diary □ Before Dat e: Tim e: Meal □ Aft er Syst olic / Diast olic: Pulse: □ Before Dat e: Tim e: Meal □ Aft er Syst olic / Diast olic: Pulse: □ Before Dat e: Tim e: Meal □...
Need help?
Do you have a question about the HL858DM and is the answer not in the manual?
Questions and answers