Summary of Contents for Qualsig WBP-101
Page 1
Model WBP-101 Qualsig Inc. Wireless Pulsewave New York, USA Blood Pressure Monitor Product Name: Wireless Pulsewave Blood Pressure Monitor Model: WBP-101 INSTRUCTION MANUAL Email: sales@qualsig.com Website: www.qualsig.com...
Page 2
Dear Customer, Thank you for purchasing the Qualsig WBP-101 Wireless Pulsewave Blood Pressure Monitor. In order to use the device correctly and efficiently, please read this Instruction Manual before use. In addition, please take good care of the manual after your reading to ensure you can find it easily when necessary.
Model WBP-101 Wireless Pulsewave Blood Pressure Monitor Model WBP-101 Wireless Pulsewave Blood Pressure Monitor CONTENTS SAFTY PRECAUTIONS The purpose of the symbols used in the Instruction as safety identifiers SAFETY PRECAUTIONS is to enable you to use the product safely and...
Page 4
Model WBP-101 Wireless Pulsewave Blood Pressure Monitor Model WBP-101 Wireless Pulsewave Blood Pressure Monitor CAUTION DESCRIPTIONS OF THE PRODUCT Be sure to use the dedicated double-bladder cuff in order to obtain accurate test results. Do not use a cellular phone near the device.
Model WBP-101 Wireless Pulsewave Blood Pressure Monitor Model WBP-101 Wireless Pulsewave Blood Pressure Monitor APPLYING THE CUFF POSTURES 1. Take off thick garments, and pull arm out of shirt sleeve to fully expose Sit in a chair beside a table with your feet on the floor.
Calibration should be performed every three years. It is • If the product is not to be used in 3 months, please store the recommended that the product be sent back to Qualsig Inc. or authorized distributors for calibration. Otherwise, accuracy may goes out device with the battery fully charged.
Model WBP-101 Wireless Pulsewave Blood Pressure Monitor Model WBP-101 Wireless Pulsewave Blood Pressure Monitor TAKING A MEASUREMENT Example of measurement results: As mentioned earlier, this device can measure in two different units: mmHg and kPa. The default unit is in "mmHg", and therefore the following guide uses "mmHg"...
Page 8
Model WBP-101 Wireless Pulsewave Blood Pressure Monitor Model WBP-101 Wireless Pulsewave Blood Pressure Monitor Within 60 seconds, you may restart a new measurement by touching the USING SMART PHONE WITH YOUR DEVICE “Remeasure”, which is not recommended, as blood circulation may not be fully recovered.
Page 9
Model WBP-101 Wireless Pulsewave Blood Pressure Monitor Model WBP-101 Wireless Pulsewave Blood Pressure Monitor From home page, you may select “My” on bottom right to access “Data” page, and then select “My report” to view details of saved results. Touch the return arrow “<” on top left to go back to home page.
Model WBP-101 Wireless Pulsewave Blood Pressure Monitor Model WBP-101 Wireless Pulsewave Blood Pressure Monitor CARE AND MAINTENANCE TROUBLESHOOTING If the device gets dirty, use soft and damp cloth (with mild detergent if ERROR INDICATORS needed) to gently wipe it. Do not use gasoline, acetone, methanol or Error other solvents.