Fuse Block |Service and Repair, Procedures: Underhood Electrical Center...
4. Connect the wire connectors to the lower portion of the electrical center block.
5. Connect the wire connectors with the bolts to the electrical center block.
Tighten
Tighten all connector bolts (1) to 9 N.m (80 lb in).
6. Ensure all wire connectors are securely connected.
7. Set the electrical center block in its resting position till the tabs (3) locks in place.