THANKS FOR CHOOSING THIS PRODUCT SUG Tools provide you with products at an affordable price, and we would like you to be fully satisfied with this product and our technical support. If any help or advice is needed, please kindly contact us.
Page 3
POWER TOOL USE AND CARE CAUTION For hand use only. Do not apply excessive torque or force to the tool housing. The torque only applies on the driver head. Do not shake or shock. Never use this digital torque tool to loosen fasteners. This digital torque tool is for hand use only.
SPECIFICATIONS Model (without AWI-10 AWI-30 AWI-60 AWI-100 communication) Minimum division 0.01 value Maximum operating 10N.m/7.37ft.lb/8 30N.m/22.12ft.lb/ 60N.m/44.25ft.l 100N.m/73.7ft.lb/ range 8.50in.lb/101.97k 265.5in.lb/305.91 b/531.04in.lb/61 885.0in.lb/1019.7 gf.cm kgf.cm 1.82kgf.cm kgf.cm (N.m) Connector(inches) 1/4 inches 3/8 inches 1/2 inches Setting range of 0.3~10N.m 0.9~30N.m 1.8~60N.m...
Page 6
ASSEMBLY BATTERY INSTALL AND REPLACEMENT 1. Open battery cover. 2. Insert battery cells, make sure the polarity is correct. 3. Close the battery cover. If doing the replacement, then do it reversely.
NOTE Remove the batteries if stored for a long period of time. Keep spare batteries on hand when going on a long trip or to cold areas. Do not mix the type of batteries or combine used batteries with new ones. Sweat, oil and water can prevent a batteries’...
Page 8
POWER ON Press P/C key to turn the digital torque tool on. After the display showed the Max measuring value for 3 second, the display will show the last Data before it was switched off. POWER OFF Press P/C key and hold for 2 seconds to switch off . RESET Press P/C key to reset.
After setting a preset value (assuming the value is 5N.m), the force applied by the wrench will gradually increase from Minimum measure value. When force is applied, the displayed value will change as the user applies different amounts of force; the reading will increase as force increased, and decrease as force decreased.
In order to get accurate data, press P/C key each time to reset the data before using the device. POWER SAVING MODE The device will be entered into power-saving mode after 2 minutes without any operation, you can press P/C key to wake it up. OVERLOAD WARNING Switch on or reset when screen continued to appear 120%, it means the device have been forced exceeds the maximum standard torque value 120%, may result in the...
WARNING NOTE FOR USING BATTERIES Please take out the batteries, if the product is not used a long period of time. Please prepare the more backup batteries, when the product is used in other places without electric power. Do not mix old and new batteries. Do not use the soiled batteries with perspiration and greasiness.
19. Do not use the additional tools to extend the length of the handle, such as: iron or plastic pipe. 20. Do not touch any button when torque is exerted. 21. The digital torque wrench cannot be applied to the conductive tools. LUBRICATE The wrench’s internal mechanism is permanently lubricated during assembly.
Need help?
Do you have a question about the AWI Series and is the answer not in the manual?
Questions and answers