Disposing of your device at the end of its useful life Safety instructions Intended Use Technical safety Components What's in the box Using the AIRcel70 Periodic cleaning procedure Correct use U-Ox - Material Safety Data Sheet (MSDS) AIRcel70 - Warranty Conditions Declaration of conformity...
Page 4
Therefore, it is critical to keep an eye on air quality at all times. U-Earth Biotech's work is based on the study of how natural active ingredients are able to clean the atmosphere by feeding on contaminants. Thanks to more than 15 years of research, it has been possible to replicate that natural process, to purify the air from viruses, bacteria and other pollutants.
Supervise children when they are near the AIRcel70. Please use the unit only for the applications indica- Do not allow children to play with the AIRcel70, put their ted and in the manner described below. Any use hands in the fan, or tip it over.
1) Installation operations must take place with no Water level power supply; sensor 2) Remove the AIRcel70 from the box and store it in a suitable place or where indicated by your Air Quality Specialist; 3) Lift the cover and place it next to the tank;...
Page 8
5) Place the lid on a flat surface; you will see the empty middle part, which ends up in the water tank, where water and the U-Ox should be placed; 5a) Remove the 2 pieces of tape from the water- plate grid;...
Page 9
7) Shake a single dose of U-Ox well and pour the entire contents of the bottle into the middle part. In Congratulations, your AIRcel70 order to ensure that the air cleaning remains e ective, is purifying the surrounding air the unit should be refilled with a single dose of U-Ox and creating a Pure Air Zone.
AIRcel70 creates a PURE AIR ZONE within a range that protects against all types of pollutants regard- less of species or size. Captured contaminants are digested by the system and converted to water, carbon dioxide and any elemental components present in the...
10) Place the lid on the side of the tank and reconnect the cable, screwing the connector; 11) Insert the cover in its seat aligning it with the AIRcel70 logo, connect the cable to the power supply and turn on the machine.
Page 12
1) Do not place AIRcel70 in areas subject to freezing temperatures. Frozen pipes may tear or burst, and the 13.6. Handling reliability of electronic equipment may be reduced at If you decide to move the appliance after its installation, temperatures below freezing.
1. U-Ox Concentrate Skin contact: not irritating to skin; wash with soap 2. Bio-detergent and water if necessary. 3. Company: U-Earth Biotech Ltd 172 Fulham Road - London SW10 9PR, United Kingdom 14.5. Fire-fighting measures info@u-earth.eu Non-combustible liquid. Not flammable.
Physical state: liquid. U-Earth provides Customers with a limited warranty on the materials and electrical/electronic components of its 14.10. Stability and reactivity AIRcel70 bioreactors under the following terms and con- Conditions to avoid: none, non-reactive liquid. ditions. Incompatibility with other materials: none.
Page 15
Customer. 15.3. Performance Warranty This materials warranty is valid for five (5) years from a) AIRcel70 bioreactors are designed to work ONLY the product delivery date. with the addition of water and U-Ox additives. The addition of products other than tap water and U-Ox 15.4.2.
Page 16
U-Ox additive will only be sold in conjunction with than or equal to the initial number of items installed. the AIRcel70 unit. The bottles must be stored in their Claims for damages, as well as any right of appeal original packaging and must not be exposed to a are excluded.
Page 17
- Temperature between 0 and 50 °C; - In the absence of condensation. The following conditions should also be observed: - Storage rooms: the rooms used for storing the equipment must be dry and well ventilated. The room must be able to maintain a more or less constant tempe- rature, neither too cold nor too hot.
EN ISO 12100:2010 Safety of machinery - General principles for design - Risk assessment and risk reduction Person authorized to store the technical files: Name and surname: Elisabetta Maggio Address: U-Earth Biotech Ltd Via Bandello 16 Milan, Italy Place: London...
Page 19
Stay in touch! Subscribe to our newsletter https://it.u-earth.eu/newsletter and follow us on social media: https://www.instagram.com/u.earthbiotech/ https://www.youtube.com/channel/UCcJCDP-SE31SauWPTdF4p-Q https://www.linkedin.com/company/u-earth-biotechnologies...
Need help?
Do you have a question about the AIRcel70 and is the answer not in the manual?
Questions and answers