The F2000 Air Decontamination System T able of Contents The Sol-Air Advantage Page 1 Warnings Page 2 Operating Instructions Page 3 The Control Panel Page 3 System Placement Page 5 Caring for the F2000 Page 6 Parts Replacement Procedures Page 7...
- Greg Lesavoy and Jordan Peccia, Ph.D., PE Sol-Air systems decontaminate air, eliminating bacteria, viruses, toxic molds and chemicals, and hundreds of unpleasant odors caused by fire, smoke, mildew, flood damage, chemical pollution, spills, sewage backup, black water, standing gray water, etc.
F 2 0 0 0 O P E R A T I O N S & M A I N T E N A N C E Warnings DISCONNECT the unit from the electrical power source before performing any maintenance on the unit. DO NOT stand in water while operating the unit.
T H E C O N T R O L P A N E L There are 2 indicator lights and 3 switches on the F2000 (Figure 1 below.) AC Power Switch (With Red Indicator) – Turns the power on/off and indicates AC power to the fan and the Unit.
Page 7
F A N S P E E D The F2000 is equipped with an Air Mover Blower Fan, which runs between 100 and 1000 Cubic Feet per Minute. In the OFF position, the fan will not be operating. Rotating the Fan Speed Switch controls the fan speed.
S Y S T E M P L A C E M E N T The manner in which you position the Sol-Air system can make a big impact on its efficiency. You may have to experiment a little to find the best position for the system.
F 2 0 0 0 O P E R A T I O N S & M A I N T E N A N C E DISCONNECT the unit from an electrical power source before Warning performing any maintenance on the unit. S Y S T E M C A S E C L E A N I N G E X T E R I O R The exterior of the machine can be cleaned with mild dishwashing detergent and a...
F 2 0 0 0 O P E R A T I O N S & M A I N T E N A N C E Parts Replacement Procedures U V L A M P S The expected life of the UV lamps may vary, depending on a number of factors including ambient operating conditions, but will generally average 9,000 hours of operation.
Page 11
F 2 0 0 0 O P E R A T I O N S & M A I N T E N A N C E Step 3 – Lamp Removal a) From the back of the system, hold the ceramic base of the lamp and disconnect the plug from the lamp.
F U S E R E P L A C E M E N T Step 1 The F2000 contains two fuses: a main fuse and a fan fuse. The main/lower fuse (6A) protects the electrical complements of the entire system and...
O P E R A T I O N S & M A I N T E N A N C E Contacting Sol-Air For replacement parts, warranty service, or any questions regarding the operation and maintenance of your Sol-Air unit, please contact us at: Version 1.5 (121506)