    TABLE OF INSTALLATION, OPERATION, MAINTENANCE CONTENTS AND REPAIR MANUAL 7.1.3- Variable Pressure Operating Mode..11 1- ATTENTION.....................3 7.1.4- Night Operating Mode........12 2- WARNINGS AND SYMBOLS........3 7.2- Error Codes..............12 2.1- Symbols Used and Types of Warnings................3 8- INITIAL OPERATION, CONTINUOUS 3- GENERAL...................5 OPERATION AND STOP........12 3.1- Description of the Pump........5 9- OPERATING MODES AND SELECTION...
  • Page 4: 1- Attention

    3.4 Operating Conditions If you need any information about your device or have OPUS circulation pumps have been developed for a problem, it will be sufficient to contact DUYAR PUMP the circulation and pressurization of the water authorized services. circulating in the heating and air conditioning systems in residences, commercial and industrial workplaces.
  • Page 5: Transport And Storage

    If the pump is damaged, it should not be used without Name of the product Name of the product consulting DUYAR PUMP authorized service. Energy Efficiency Index 5. PUMP INFORMATION Maximum System Pressure Maximum System Pressure 5.1 Technical Information...
  • Page 6: Parallel/Backup Operation

    OPUS SERIES INSTALLATION, OPERATION, MAINTENANCE AND REPAIR MANUAL 5.3 Parallel/Backup Operation 6.3 Water Filling and Air Drain In order for the pump to operate efficiently, unharmed If more than one pump is installed for backup and noise-efficiently, the air of the installation must be...
  • Page 7: 7- Display And Settings

    OPUS SERIES INSTALLATION, OPERATION, MAINTENANCE AND REPAIR MANUAL 7. DISPLAY AND SETTINGS The OPUS display consists of nine LEDs and three control keys. See. Figure 7.1. The control screen provides information about the pump status and allows the desired operating mode to be set.
  • Page 8: Operating Modes

    OPUS SERIES INSTALLATION, OPERATION, MAINTENANCE AND REPAIR MANUAL 7.1 Operating Modes 7.1.4 Night Operating Mode - Manual Mode Press and hold the "P" key for 3 seconds to set the target - Constant Pressure Mode speed in night work. When the P7 option is reached - Variable Pressure Mode with the "+"...
  • Page 9: Variable Pressure Operating

    OPUS SERIES INSTALLATION, OPERATION, MAINTENANCE AND REPAIR MANUAL 9. OPERATING MODES AND 9.2 Constant Pressure Operating Mode SELECTION CRITERIA setting OPUS circulation pumps, with their ECM technology, provide operating modes that act in accordance with the variable flow requirement. Flow Q (m3/h) OPUS Operating Modes Figure 9.3: Constant Pressure Operating Mode Display...
  • Page 10: Operating Mode Selection

    OPUS SERIES INSTALLATION, OPERATION, MAINTENANCE AND REPAIR MANUAL In this operating mode, the pump operates by changing the rotation speed to follow a linear line between the set pump head (Hsetting) and half of the set value (Hsetting /2). The pump provides a head on this line depending on the decrease or increase in flow.
  • Page 11: Terminal Connection Detail Parame

    OPUS SERIES INSTALLATION, OPERATION, MAINTENANCE AND REPAIR MANUAL 10. TERMINAL CONNECTION DETAIL 10.1 Terminal Connection Detail Table Relay Link communication devices Communications RS485 DIN2 contact DIN1...
  • Page 12 OPUS SERIES INSTALLATION, OPERATION, MAINTENANCE AND REPAIR MANUAL 10.2 Terminal Connection Detail Param eter List Para eter Se n 0 - Watts 0 - Watts 1 - Meter (Mt) 1 - Meter (Mt) Image Selection Image Selection 2 - Current (A)
  • Page 13: 11- Faults, Causes And

    OPUS SERIES INSTALLATION, OPERATION, MAINTENANCE AND REPAIR MANUAL 11. FAULTS, CAUSES AND SOLUTIONS When a situation occurs that prevents the normal operation of the pump, the pump automatically stops and gives an error or warning code. See Figure 7.1. Thanks to the codes written on the screen, the cause and solution of the error can be learned.
  • Page 14 OPUS 50-8 240 C 4x14 4x18 10,00 OPUS 40-10 220 4x14 4x18 9,80 OPUS 50-8 240 4x14 4x18 10,70 OPUS 40-12 250 V 4x14 4x18 9,70 OPUS 50-12 280 V 4x14 4x18 11,00 Dimensions OPUS SERIES INSTALLATION, OPERATION, MAINTENANCE AND REPAIR MANUAL...
  • Page 15: Service

    The warranty certificate will be filled by the authorized DUYAR POMPA dealer from where the device was purchased and sent to DUYAR POMPA and a copy will be given to the user.
  • Page 16 Customs and Trade, General Directorate of Consumer Protection and Market Surveillance. Manufacturer: Seller Company : Seller Company: Duyar Pompa ve Hidrofor Sistemleri San. ve Tic. A.Ş. Title: Dudullu OSB Mah. İMES -101 .Sk. imes Sit A Blok No:13 Address : Ümraniye - İstanbul /TÜRKİYE...
  • Page 17 STAINLESS FIRE BOOSTER BOOSTER DNP HORIZONTAL END SUCTION PUMP SINGLE-STAGE, END SUCTION, CLOSED WHEEL, ELECTRIC OR DIESEL ENGINE, AXIAL TYPE PUMP More Details...
  • Page 18 WE A RE S E N SI BLE TO LIV E 2021.11.1...

Table of Contents