Quick Links

DATASHEET
Manufacturer:
Hatteland Technology AS
External Remote Controller for Monitors
Product:
Typenumber:
HD REM SX1-A1
External Remote Controller for Monitors
Description:
The remote controller enables the control of Series 1 G2, Series X G1, Series X G2, MVD Series and selected HM CMD / RMD monitors
by providing instant keypad functionality over RS-485/422 bus through the well implemented SCOM Protocol by Hatteland Technology
AS. A single press on the remote controller will trigger the same physical press on all connected/configured units with the
synchronized reaction of corresponding button presses. The remote controller provides several functions through 3 physical buttons
for user interaction. Remote Control is powered and driven by first monitor unit (which has to be connected to external power cable/
source. It is not required to turn the monitor unit on for the Remote Control to control/operate other monitor units that may be in
the same chain).
Specifications:
• Connector
1 x 6-pin Terminal Block 3.81, non-isolated
• Mounting
Includes mounting bracket with 2 x PanHead M3x6mm.
(Tightening Torque 0.8 Nm) and 2 x Thumb Fastening screws for console
mounting.
• Physical Dimensions
W:125.00 [4.92"] x H:37.50 [1.48"] x D:72.30 [2.83"] mm [inch]
• Weight
123g
• Connectivity
- Shipped with 1 x 6-pin Terminal Block 3.81 loose connector (Art: 1828388)
- Connect Remote Control to first display unit, other units in connection chain
will receive same commands.
- See page 2 for Physical Wire Connections.
• User Manual
- This datasheet. Detailed usage: SCOM Technical Manual can be used with
command-set regarding User Controls:
Series 1 G2 models:
https://www.hattelandtechnology.com/hubfs/pdfget/inb100018-12.htm
Series X G1 models:
https://www.hattelandtechnology.com/hubfs/pdfget/inb100018-4.htm
Series X G2 models:
https://www.hattelandtechnology.com/hubfs/pdfget/inb100018-6.htm
Multi Vision Display MVD models:
https://www.hattelandtechnology.com/hubfs/pdfget/inb100018-8.htm
• Test and certificate
Hatteland Technology standard, (tested / type approved by the
following classification societies):
IEC 60945 4th (EN 60945:2002), IACS E10,
EU RO MR - Mutual Recognition, ClassNK - Nippon Kaiji Kyokai
FRONT VIEW
TOP VIEW (w/ console panel)
Dimensions might be shown with or without decimals and indicated as mm [inches]. Tolerance on drawings is +/- 1mm. For accurate measurements, check relevant DWG fi le.
Hatteland Technology AS | www.hattelandtechnology.com | Enterprise no: NO974533146
This information may not, in whole or in part, be copied, photocopied,
reproduced, translated or reduced to any electronic medium or machine-
readable form without the prior written consent of Hatteland Technology
AS. The products may not be copied or duplicated in any way.
BACK VIEW
PANEL CUTOUT
Last Revised:
Revision#:
1 2 3 4 5 6
ACCESSORY
16 Sep 2022
21
SIDE VIEW
1/6
1/2

Advertisement

loading

Summary of Contents for Hatteland HD REM SX1-A1

  • Page 1 The remote controller enables the control of Series 1 G2, Series X G1, Series X G2, MVD Series and selected HM CMD / RMD monitors by providing instant keypad functionality over RS-485/422 bus through the well implemented SCOM Protocol by Hatteland Technology AS.
  • Page 2 SPECIFICATIONS Note: All specifi cations are subject to change without prior notice! Please visit www.hattelandtechnology.com for the latest electronic version. Button layout and functions: The Remote Controller is designed to simulate the regular 6-button available on the Glass Display Control (GDC™) as default available on all Series X products via a timer-based configuration explained as "Normal"...
  • Page 3: Initialization Mode

    SPECIFICATIONS Note: All specifi cations are subject to change without prior notice! Please visit www.hattelandtechnology.com for the latest electronic version. Remote Control schematic logic: Remote Control has several states of which its logic is interpreted. These modes are identified as Start, OFF mode, Initalization Mode, Normal Mode and Menu Mode.
  • Page 4: Normal Mode

    SPECIFICATIONS Note: All specifi cations are subject to change without prior notice! Please visit www.hattelandtechnology.com for the latest electronic version. Normal mode: The Status RGB LED will be lit in green depending on logic detected as illustrated below. This mode is dependent on configuration, key presses and responses. Responses can be either internal logic or by user intervention such as On-button-first-press (On Down), press-and-hold or just press-and-release on any of the physical buttons within the milliseconds indicated below.
  • Page 5: Menu Mode

    SPECIFICATIONS Note: All specifi cations are subject to change without prior notice! Please visit www.hattelandtechnology.com for the latest electronic version. Menu mode: The Status RGB LED will be lit in green or be off (black) depending on logic detected as illustrated below. This mode is dependent on configuration, key presses and responses.
  • Page 6 Physical wire connections: Use loose Terminal Block Connectors from Package of Contents that followed the monitor unit and the HD REM SX1-A1 Remote Control. Cables and Cable length must be provided by customer. Recommended Cable Thickness: Minimum 22 AWG - Maximum 18 AWG. Creation/cabelling illustrates a 2 unit setup.