Table of Contents

Advertisement

Quick Links

iP Master stations
instAllAtion & ConFiGURAtion GUiDE
TECHNICAL MANUAL
A100K10788

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A100K10788 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Stentofon A100K10788

  • Page 1 Master stations instAllAtion & ConFiGURAtion GUiDE TECHNICAL MANUAL A100K10788...
  • Page 2 About this Document Document Scope This document describes the installation and configuration of the various models of the STENTOFON IP Master Station range including accessories such as the IP DAK-48 unit, gooseneck microphone and handset. Revision Information Rev. Date Author...
  • Page 3: Table Of Contents

    E.2 IP OR Master Station ......................36 E.3 IP Flush Master Station ......................37 E.4 IP DAK-48 Unit ........................37 E.5 IP Dual Display Station ......................38 E.6 IP Master Station Kit ......................38 F: User Quick Reference ......................... 39 A100K10788 IP Master Station Installation & Configuration...
  • Page 4 Figures Figure 1 STENTOFON Security and Communication System ............5 Figure 2 IP Desktop Master Station Keys & Functions ............... 6 Figure 3 IP Flush/OR Master Station Keys & Functions ..............7 Figure 4 IP Dual Display Station Keys & Functions ................8 Figure 5 RJ45 Ports at Rear of IP Desktop Master Station ..............
  • Page 5: Introduction

    Introduction The STENTOFON IP Master Stations are connected to the AlphaCom XE server/exchange which is the heart of the STENTOFON security and communication system. The communication between the AlphaCom XE exchange and the IP Master Stations utilize the STENTOFON CCoIP ®...
  • Page 6: Ip Desktop Master Station

    The station has an excellent audio quality. With a large backlit display and STENTOFON audio technology, the station allows users to read caller ID, listen and talk at a distance.
  • Page 7: Ip Flush Master Station

    This opens up for a wide range of integrations and applications such as: ● Advanced call request handling with visual indications ● CCTV and intercom integration ● Dynamic group call and PA zone selection ● Simplex (radio) conference with visual indications A100K10788 IP Master Station Installation & Configuration...
  • Page 8: Ip Dual Display Station

    PCB can extract power from the Ethernet’s PoE circuit and provide up to 6 W power to external units. This means that the PCB can power an external power amplifier using its own PoE. A100K10788 IP Master Station Installation & Configuration...
  • Page 9: Installation

    Installation Introduction The table below is an overview of the main connectors involved when installing the STENTOFON IP Master Stations. 10/100 Mbps RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
  • Page 10: Handset

    ● Insert the RJ11 plug of the handset into the lower port of the dual RJ11 ports on the lower left of the station. Handset IP Flush Master Station Dual RJ11 Ports RJ11 Plug STENTOFON Figure 8 Installing the Handset A100K10788 IP Master Station Installation & Configuration...
  • Page 11: Headset

    RJ11 ports on the lower left of the station. IP Flush Master Station Headset Dual RJ11 Ports RJ11 Plug STENTOFON Figure 9 Installing the Headset Connector pin settings for the headset can be found in Appendix A: Station Board Connections. A100K10788 IP Master Station Installation & Configuration...
  • Page 12: Gooseneck Microphone For Ip Flush Master

    5. Slide the S1 switch (bottom back of station) to EXT to activate the external microphone function. Gooseneck Microphone Microphone Cable Cover Plug IDC Socket 3-pin header Slide Switch Figure 10 Installing the Gooseneck Microphone for Flush Master A100K10788 IP Master Station Installation & Configuration...
  • Page 13: Gooseneck Microphone For Ip Dual Display

    These connections are used for as relay contacts for door lock control and external I/O devices. For pin settings on the P3 and P4 connectors on the station board, see Appendix A Station Board Connections. A100K10788 IP Master Station Installation & Configuration...
  • Page 14: Ip Dak-48 Unit

    To add another DAK unit, plug one end of an RJ45-RJ45 cable into the RJ45 port of the installed unit and plug the other end into the RJ45 port of the new unit. A100K10788 IP Master Station Installation & Configuration...
  • Page 15: Configuration

    Set the IP address of AlphaCom that the station shall connect to, and the directory number of the station. If a directory number is not entered, the station will register with its MAC address. Back A100K10788 IP Master Station Installation & Configuration...
  • Page 16: Configuration Via Web Browser

    3. Enter the default password: alphaadmin The Station Information page will now be displayed, showing the IP station configuration including the MAC address which needs to be entered into the AlphaPro programming tool. A100K10788 IP Master Station Installation & Configuration...
  • Page 17: Station Main Settings

    ● Static IP – Select this option if the IP station shall use a static IP address. Enter values for: - IP-address - Subnet-mask - Gateway ● Click Save followed by Apply to apply the new configuration settings. A100K10788 IP Master Station Installation & Configuration...
  • Page 18: Advanced Configuration Options

    — is commonly used to refer to the encapsulation protocol used to implement this mechanism over Ethernet networks. " STENTOFON IP Stations support 802.1Q as from firmware version 01.09.3.0. A100K10788 IP Master Station Installation & Configuration...
  • Page 19 VLANs. For example, if the chosen option is MEMBERS then a packet with VLAN ID 1 at the LAN port will only reach another port which is a member of VLAN ID 1. Select A100K10788 IP Master Station Installation & Configuration...
  • Page 20: Network Access Control

    LAN, either establishing a point-to-point connection or preventing it if authentication fails. " STENTOFON IP Stations support 802.1X as from firmware version 01.09.3.0. User interface 802.1X Network Access Control is configured from the IP station web interface.
  • Page 21 Rules (DER) format, and it must be named certificate.pem. ● Click Save to save the current settings ● Click Reboot - The new 802.1X settings will only come into effect after the reboot. A100K10788 IP Master Station Installation & Configuration...
  • Page 22: Software Upgrade

    4. Enter the IP address of the TFTP server (your PC IP address) 5. Enter the name of the software Image file (include bin file extension) 6. Enter the CRC checksum (found in the text file from the downloaded software package) A100K10788 IP Master Station Installation & Configuration...
  • Page 23: Upgrade Via Alphacom Xe

    IP station may lose contact with the TFTP server (depending on the configuration when 802.1X authentication fails). If the IP station loses contact with the TFTP server, it will not be upgraded. A100K10788 IP Master Station Installation & Configuration...
  • Page 24: A: Station Board Connections

    6-pin plug-on screw terminal for external connections. Pin 1/2 Connect to 1.5 W loudspeaker. RELAY Typical impedance: 8 Ω Recommended impedance: 6-25 Ω. 0V EXT Pin 3/4 Internal NO relay contact for door lock 24V EXT control etc. A100K10788 IP Master Station Installation & Configuration...
  • Page 25 A1 (GND) Pin 4 NC (GND) Pin 5 Pin 6 SCL (Clock) Pin 7 SDA (Data) Pin 8 +13 V 3-pin header for connecting gooseneck microphone. Pin 1 MIC+ Pin 2 MIC- Pin 3 A100K10788 IP Master Station Installation & Configuration...
  • Page 26 Pin 1 OFFHOOK Pin 2 Pin 3 Slide-switch to select internal microphone (Int) or gooseneck microphone (Ext). 1 2 3 4 4-way DIP switch for future use. Leave all in default OFF position. A100K10788 IP Master Station Installation & Configuration...
  • Page 27: B: Station Indication Leds

    - Station has no connection to the AlphaCom XE exchange. Blinking 1 red + 2 green - Station connected but NOT registered in the AlphaCom XE exchange. Blinking 3 green - Station connected and registered in the AlphaCom XE exchange A100K10788 IP Master Station Installation & Configuration...
  • Page 28: Power Led

    These LEDs are on the LAN (P1) and AUX (P2) RJ45 ports. Left LED Steady light: Ethernet connection OK Blinking: Ethernet traffic No light: No Ethernet connection Right LED Light: 100 Mbit Ethernet connection No light: 10 Mbit Ethernet connection A100K10788 IP Master Station Installation & Configuration...
  • Page 29: C: Dimensions & Mounting Instructions

    67 x 280 x 41 mm 0.4 kg Table 3 Station Dimensions C.1 IP Desktop Master Station with Handset Figure 16 IP Desktop Master with handset - Dimensions C.2 IP Desktop Master (Handset) Wall Mounting Figure 17 IP Desktop Master (handset) Wall Mounting A100K10788 IP Master Station Installation & Configuration...
  • Page 30: Ip Desktop Master Station

    C.3 IP Desktop Master Station Figure 18 IP Desktop Master - Dimensions C.4 IP Desktop Master Wall Mounting Figure 19 IP Desktop Master Wall Mounting A100K10788 IP Master Station Installation & Configuration...
  • Page 31: Ip Flush Master Station

    Backboxes for flush mounting, surface mounting, as well as the handset are available for the IP Flush Master Station. Backbox for Handset Backbox for Flush Mount Station Backbox for Surface Mount Station Figure 21 IP Flush Master - Backboxes A100K10788 IP Master Station Installation & Configuration...
  • Page 32: Ip Or Master Station

    2. Align the four retention pegs with the four plastic retainers and push the station down until flush with the backbox. retainer retainer retainer retainer backbox Figure 23 Mounting the IP OR Master Station A100K10788 IP Master Station Installation & Configuration...
  • Page 33: Ip Dual Display Station

    Do not lift the station at an angle as this may damage the pegs. Figure 24 Demounting the IP OR Master Station C.9 IP Dual Display Station Figure 25 IP Dual Display Station - Dimensions A100K10788 IP Master Station Installation & Configuration...
  • Page 34: Ip Master Station Kit

    C.10 IP Master Station Kit 82 mm 4 mm DISPLAY on front side PCB rear side 26 mm 6 mm 78 mm 88 mm Figure 26 IP Master Station Kit PCB Dimensions A100K10788 IP Master Station Installation & Configuration...
  • Page 35: D: Restoring Factory Defaults

    2. Keep KEY1 pressed while powering up the station. KEY3 3. Release KEY1 after precisely two blinks of the station LED, then press KEY1 briefly again. The station will come up with the factory settings. A100K10788 IP Master Station Installation & Configuration...
  • Page 36: E: Station & Accessory Specifications

    2 x RJ45 (Ethernet) 10/100 Mbps IP protocols IP v4 - TCP - UDP - HTTPS – TFTP - RTP - RTCP -DHCP - SNMP - DiffServ - TOS – STENTOFON CCoIP® LAN protocols Power over Ethernet (IEEE 802.3 a-f), VLAN (IEEE 802.1pq), Network Access Control (IEEE 802.1x), STP (IEEE 802.1d), RSTP (IEEE 802.1d-2004)
  • Page 37: Ip Flush Master Station

    Pluggable screw terminals (I/O local power) IP protocols IIP v4 - TCP - UDP - HTTPS – TFTP - RTP - RTCP -DHCP - SNMP - DiffServ - TOS – STENTOFON CCoIP® LAN protocols Power over Ethernet (IEEE 802.3 a-f), VLAN (IEEE 802.1pq), Network Access Control (IEEE 802.1x), STP (IEEE 802.1d), RSTP (IEEE 802.1d-2004)
  • Page 38: Ip Dual Display Station

    Power over Ethernet, IEEE 802.3 a-f, Class 0, Idle 4W, max. 8W IP protocols IP v4 - TCP - UDP - HTTPS – TFTP - RTP - RTCP -DHCP - SNMP - DiffServ - TOS – STENTOFON CCoIP® LAN protocols Power over Ethernet (IEEE 802.3 a-f), VLAN(IEEE 802.1pq), Network Access Control (IEEE 802.1x), STP (IEEE...
  • Page 39: F: User Quick Reference

    Away for a few days (until date: ddmm) There are deliveries for you Not available (Available on phone number: xxxx) " The numbers on this page are factory default settings and may have been changed in your AlphaCom exchange installation. A100K10788 IP Master Station Installation & Configuration...
  • Page 40 A100K10788 STENTOFON and VINGTOR products are developed and marketed by Zenitel Norway AS. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001:2008. Zenitel Norway AS reserves the right to modify designs and alter specifications without prior notice, in pursuance of a policy of continuous improvement. © 2010 Zenitel Norway AS.

Table of Contents