Download Print this page

Bison 170-101-0212 Quick Start Manual

Advertisement

Quick Links

D I M E N S I O N S
D501
R501
J4
R25
3.58 [91]
1.75 [44]
J5
C6
J3
A -- INHIBIT -- B
0.74 [19]
1.41 [36]
0.96 [24]
S P E C I F I C A T I O N S
Input Voltage +/- 10%, 50/60 Hz
Output Voltage (VDC)
Maximum Continuous Output for one motor (Amps)
Maximum Total output for combined motors (Amps)
Individual motor HP range
Maximum Total HP rating of both sides combined
Form Factor
* Heatsink (part number 170-990-0100) is required if one side provides more than 5A or the total output of
both sides is more than 6.5A.
4.30 [109]
D502
Q502
Q504
Q503
C505
C506
C502
R503
U3
U2
MOV502
C501
C4
A B
U
1
R26
J
J2
A-B
S3
S2
S
S3
S2
S
* With Heatsink
* Without Heatsink
115 VAC
115 VAC
0 - 90
0 - 90
10
5
11.5
6.5
1/15 - 1
1/15 - 1/2
1 1/8
5/8
1.37
1.37
Q U I C K
MOTOR A
0.19 [5]
6 PLACES
FUSE
MASTER
POWER
SWITCH
1.53 [39]
LINE
VOLTAGE
INPUT
115 VAC
Motor Connections
The 170-101-0212 drive supplies motor voltage from A+ and A- terimnals. It is assumed that
when A+ is positive with respect to A-, the motor will rotate clockwise (CW) while looking at the
output of the shaft protruding from the front of the motor. If this is opposite of the desired
rotation, reverse the wiring of the A+ and A- terminals.
Power Input
Connect the AC power leads to terminals L1 and L2, or to a double-pole single-throw master
power switch (recommended).
Line Fuse
Wire an external line fuse between the stop switch (if installed) and the L1 terminal.
Speed Potentiomenter Connections
Speed adjustments are supplied by speed potentiometers connected to J1 and J2 (Factory
supplied pot kit includes two sets of potentiometer hardware).
170-101-0212
D u a l M o t o r C o n t r o l S C R D C D r i v e
S T A R T
G U I D E
C O N N E C T I O N S
Q502
Q504
D501
Q503
C505
C506
C502
M
R501
U3
U2
J4
R25
MOV502
C4
J5
C6
U1
J3
1
J1
J2
A -- INHIBIT -- B
A-B
S3
S2
S1
S3
S2
S1
SPEED A
RATIO OR SPEED B
POTENTIOMETER
POTENTIOMETER
CLOSE TO INHIBIT DRIVE
MOTOR B
D502
R503
C501
A B

Advertisement

loading

Summary of Contents for Bison 170-101-0212

  • Page 1 CLOSE TO INHIBIT DRIVE Motor Connections The 170-101-0212 drive supplies motor voltage from A+ and A- terimnals. It is assumed that S P E C I F I C A T I O N S when A+ is positive with respect to A-, the motor will rotate clockwise (CW) while looking at the output of the shaft protruding from the front of the motor.
  • Page 2 Motor A (B). STOPPING: DECEL vs. COAST (J5) There are two methods of stopping: DECEL and COAST. Bison Gear & Engineering Corp. 3850 Ohio Ave. -- St. Charles, IL 60174 Phone: 1-800-AT-BISON DECEL - Placing a jumper on pins 1 and 2 of J5 and closing the inhibit terminals will cause the motor www.bisongear.com...