WARNING ELECTRICAL SHOCK HAZARD! Before installing, modifying, or servicing system, the main electrical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label. Failure to follow these instructions could result in personal injury or death CAUTION LACERATION, BURN HAZARD Laceration, burn hazard.
PARTS LIST Table 1—INCLUDED ITEMS PART NO. PART NAME QTY. Outdoor unit Literature package including installation instructions and warranty Grommet to secure the outdoor unit (helps with vibration prevention during unit operation) Drain Joint Drain Hose Conversion Joints (see Table 4) FIGURE 1 NOTE: −...
SYSTEM REQUIREMENTS Allow sufficient space for airflow and service of the unit. See Table 5 and Figure 5 for the required minimum distances between the unit, walls or ceilings. Table 3—Performance and Specifications Outdoor Condensing Unit Model DHMZ218DA DHMZ327DA DHMZ436DA Power supply 208-230/ 1/60 208-230/ 1/60...
Conversion Joints: The outdoor unit includes a package of conversion joints to facilitate installation of the various fan coil sizes. These joints are to be connected to the outdoor unit as needed to match the line set size. Table 4—Conversion Joints No.
FIGURE 5 - Clearances Air-inlet Air-outlet Table 5 Clearances MINIMUM VALUE Reference in. (mm) 24 (609) 24 (609) 24 (609) 4 (101) 6 (152) NOTE: Outdoor Unit must be mounted at least 2in (50mm) above the maximum anticipated snow depth. FIGURE 6 Clearances for multiple units...
INSTALLATION GUIDE Up to four fan coil units can be connected to one outdoor unit. S Avoid sags in the piping to prevent the formation of oil traps. Refer to the product data for approved combinations. Insulate each tube with minimum 3/8in. (10 mm) wall thermal pipe insulation.
INSTALL ALL POWER AND INTERCONNECTING DRAIN CONNECTIONS WIRING TO OUTDOOR UNIT Install drains must meet local sanitation codes. 1. Mount the outdoor power disconnect. Install the outdoor unit drain joint 2. Run power wiring from the main box to the disconnect per Fit the seal into the drain joint, then insert the drain joint into the NEC and local codes.
CONNECTION DIAGRAMS Indoor Indoor Indoor Unit A Indoor Unit B Unit A Unit B Power Supply Power Supply Ground Ground Signal Signal High High 208-230-1-60 208-230-1-60 Voltage Voltage CONNECTING CABLE CONNECTING CABLE 208-230-1-60 OUTDOOR TO INDOOR FIELD POWER SUPPLY OUTDOOR TO INDOOR L1(B) L2(B)S(B) L1(A) L2(A)
SYSTEM VACUUM AND CHARGE 10. Reference Table 5 when additional charge is needed. CAUTION Disconnect the charge hoses and manifold gauge. Using a hexagonal wrench, fully open all the gas and liquid UNIT DAMAGE service valves for the size 18 and all the Master Gas and Liquid service valves for sizes 27−36 (see Fig.
Page 15
START−UP Deep Vacuum Method The deep vacuum method requires a vacuum pump capable of pulling a vacuum of 500 microns and a vacuum gauge capable of CAUTION accurately measuring this vacuum depth. The deep vacuum method is the most positive way of assuring a system is free of air and DO NOT apply power to the outdoor unit if the Master liquid water (see Fig.