  • Page 1 Magnetic-Inductive Flow Velocity Sensor UMF2 Operating Manual Please read the instructions carefully and store them in a save space Heinrichs Messtechnik GmbH OPERATING MANUAL PIT / UMF2B January 2021...
  • Page 2: Table Of Contents

    Heinrichs Messtechnik GmbH Contents INTRODUCTION .................................4 Shipping and storage; product inspection ........................4 Warranty ....................................4 III. Maintenance, Repair and Hazardous substances..................... 4 Disposal ....................................4 Supplementary operating instructions ........................4 STEPS PRIOR TO OPERATION ........................5 IDENTIFICATION ..............................6 APPLICATION ..............................7 MODE OF OPERATION AND SYSTEM DESIGN....................8...
  • Page 3 Heinrichs Messtechnik GmbH OPTIONS…………………………………………………………………………..……………………………………………………..18 10.1 Removal and installation under process pressure ....................18 10.2 PIT (Sensor) Ingress protection IP68 .......................... 18 10.2.1 Wiring diagram for remote installation ....................... 19 RETURNING THE METER ..........................20 11.1 Declaration of Decontamination ..........................21 DECLARATION OF CONFORMITY ........................
  • Page 4: Introduction

    11 “Returning the Meter”. before returning the device to Heinrichs Messtechnik. The operator is liable for any substance removal or personal damage costs arising from inadequate cleaning of a device sent for repair.
  • Page 5: Steps Prior To Operation

    The device is to be installed and serviced by a qualified technician only. The UMF2B transmitter is to be used exclusively to measure volume flow or flow velocity, in conjunction with a Heinrichs Messtechnik EPS, PIT or PITE sensor.
  • Page 6: Identification

    Heinrichs Messtechnik GmbH 2 Identification Hersteller: Heinrichs Messtechnik GmbH Robert-Perthel-Strasse 9 D-50739 Köln Deutschland Fon: +49 221 49708-0 Fax: +49 221 49708-178 Internet: www.heinrichs.eu E-Mail: info@heinrichs.eu Produkttyp: Magnetic – inductive flow sensor based upon Faraday’s law of induction Produktname: Sensortyp:...
  • Page 7: Application

    Heinrichs Messtechnik GmbH 3 Application The magnetic-inductive flow velocity sensor PIT-UMF2 is used to measure or monitor the volume flow of liquids with and without solids concentration, slurries, pastes and other electrically conductive media while minimizing pressure drops. The medium must possess a conductivity of at least 20 µS/cm.
  • Page 8: Mode Of Operation And System Design

    Heinrichs Messtechnik GmbH 4 Mode of Operation and System Design 4.1 Mode of operation It was back in 1832 that Faraday suggested utilizing the principle of electromagnetic induction for measuring flow velocities. His experiments in the Thames, though unsuccessful due to superimposed polarization effects, are nonetheless regarded as the first ones in the field of magnetic-inductive flow measurement.
  • Page 9: System Design

    The PIT-*** sensor can be operated with all transmitters for magnetic-inductive flow meters manufactured by Heinrichs Messtechnik. The sensor is installed (inserted) into the pipe while the transmitter is mounted directly on top of the sensor or separate remote, depending on the equipment design.
  • Page 10: Remote Installation Of The Transmitter

    4.2.2 Remote installation of the transmitter Heinrichs Messtechnik recommends this type of installation when there is little space or the medium temperatures are high. The sensor and the transmitter are connected by a field coil and an electrode cable. The electrode cable must be shielded and protected against disturbing interferences.
  • Page 11: Characteristics

    Heinrichs Messtechnik GmbH 5 Characteristics Accuracy  1.5 % of measured value plus  0.5 % of URV Conductivity of fluid  20 µS/cm Influence of ambient temperature Pulse output  0, 05% pro 10K Current output  0, 1% pro 10K...
  • Page 12: Conditions Of Use

    Heinrichs Messtechnik GmbH 6 Conditions of use 6.1 Installation conditions Disturbing elements (e.g. shut-off and control valves) are to be arranged downstream from the sensor. If this is not possible, flow conditioners must be installed so that no vortexes can reach the pipe section of the sensor.
  • Page 13: Grounding

    Heinrichs Messtechnik GmbH 6.1.3 Grounding For safety reasons and to ensure faultless operation of the magnetic-inductive flow meter, earthing of the flow sensor is important. In accordance with VDE 0100, Part 540, the earthing connections must be connected to the grounding conductor.
  • Page 14: Medium Temperature And Pressure

    Heinrichs Messtechnik GmbH 6.4 Medium temperature and pressure 6.4.1 Direct mounted transmitter Version Medium temperature Pressure PIT-S ( SS / PTFE) -20°C to 80°C 16 bar PIT-A ( PFA) -20°C to 80°C 40 bar 6.4.2 Remote mounted transmitter Version Medium temperature...
  • Page 15: Dimensions/Weight

    Heinrichs Messtechnik GmbH 7 Dimensions/weight 7.1 PIT-UMF2 dimensional drawing for remote transmitter Transmitter with terminal connection box (all dimensions in mm ) Weight: 3, 6 kg Nominal Diameter Transmitter with directly connected cable ( up to 10 m) Length of sensor Ød:...
  • Page 16: Pit-** Dimensional Drawing With Direct Mounted Transmitter Umf2

    Heinrichs Messtechnik GmbH PIT-** dimensional drawing with direct mounted transmitter UMF2 (all dimensions in mm ) Weight: 5, 5 kg Nominal Diameter Length of sensor Ød: Diameter of sensor Length of socket weld fitting Ød1 Version PIT-A (PFA) 150-600 163mm...
  • Page 17: Power Supply / Electrical Connection

    Heinrichs Messtechnik GmbH 8 Power supply / electrical connection See name plate or Operating Instructions of the corresponding transmitter. 9 Safety information 9.1 Intended use The PIT-UMF2 flow meter may be used only for flow measurements of fluids whose conductivity exceeds 20µS/cm.
  • Page 18: Options

    Heinrichs Messtechnik GmbH 10 Options 10.1 Removal and installation under process pressure In some cases it might be necessary to remove and reinstall the PIT sensor head for cleaning when the pipe is under process pressure. A special retraction device can be used for this purpose.
  • Page 19: Wiring Diagram For Remote Installation

    Heinrichs Messtechnik GmbH 10.2.1 Wiring diagram for remote installation The outer shield hast o be connected to the metalized cable glands at both ends. The inner shields are connected to each other and are plugged into the terminal with the label “Schirm / shield”.
  • Page 20: Returning The Meter

    Heinrichs Messtechnik GmbH 11 Returning the Meter If all attempts to return the device to an operational condition have failed, contact our service department to arrange the return of your device for repair. Before sending the device back for repair or servicing, please ensure the following steps have been performed: Always enclose a fully completed declaration of decontamination.
  • Page 21: Declaration Of Decontamination

    Heinrichs Messtechnik GmbH 11.1 Declaration of Decontamination Company name: ..............Address: ................Department: ................ Contact person: ..............Phone: .................. The enclosed Coriolis flow meter Model: ..........................was operated using the following fluid: ........................... In as much as this fluid is water-hazardous / toxic / corrosive / combustible / a health hazard /...
  • Page 22: Declaration Of Conformity

    Heinrichs Messtechnik GmbH 12 Declaration of Conformity Page 22 of 23 Operating Manual PIT / UMF2B...
  • Page 23 Heinrichs Messtechnik GmbH Operating Manual PIT / UMF2B Page 23 of 23...