Kongskilde FAST Assembling Instructions And Maintenance

Oil-fired air heater

Advertisement

Quick Links

OIL-FIRED
AIR HEATER
FAST
TECHNICAL INFORMATION
ASSEMBLING INSTRUCTIONS
USE AND MAINTENANCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FAST and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kongskilde FAST

  • Page 1 OIL-FIRED AIR HEATER FAST TECHNICAL INFORMATION ASSEMBLING INSTRUCTIONS USE AND MAINTENANCE...
  • Page 2 CONFORMITY...
  • Page 3 FAST heaters are produced according to : • Machinery Directive 89/392/CEE, 91/368/CEE, 93/44/CEE and 93/68/CEE • Low Voltage Directive 73/23/CEE. RANGE MODEL FAST 35 FAST 60 FAST 95 FAST 110 Dear Customer,...
  • Page 4: Warranty

    The heater is very quiet and safe specialy when maintenance is made by our KONGSKILDE Technical Service. The instruction manual contains important information that must be followed to install...
  • Page 5 INDEX Page 1 Conformity 2 Range 3 Warranty 4 Index 5 General notions 6 Safety rules 7 Description of the heater 8 Identification 9 Parts 10 Sizes 11 Combustion chamber size 12 Technical data 13 Handling and transport 14 Location 15 Head 16 Ducting 17 Fixed protection...
  • Page 6: Safety Rules

    3) The FAST heater must be installed by a qualified installer according to the laws in force 14) KONGSKILDE will not be held responsible...
  • Page 7: Description Of The Heater

    It is not allowed to scatter, abandon or leave within childrens reach any packaging (such as DESCRIPTION OF THE HEATER The FAST heater functions by using the thermal The thermal exchange occurs when the air flow, energy produced through combustion.
  • Page 8 • Centrifugal with suction inlets, noiseproof, high performance, single voltage electrical motor directly connected centrifugal fan. IDENTIFICATION The FAST heater be identified through are marked, it is positioned directly inside the burner Technical Data plate where all technical specifications cabinet.
  • Page 9 If the data plate is damaged or lost it is KONGSKILDE Technical Service. necessary to request a duplicate from the AIR HEATER Code Model Serial plate number Country Thermal input Thermal oytput Air flow (+20°C) Electrical feeding Motor power Maximum current of motor...
  • Page 10: Technical Data

    Size (mm) FAST 35 FAST 60 FAST 95 FAST 110 1.050 1.120 1.220 1.400 1.600 1.700 1.885 2.000 1.175 1.305 1.430 1.570 ∅ Chimney SIZE OF COMBUSTION CHAMBER The heat exchanger has 3 smoke rings and the combustion chamber has the following size:...
  • Page 11: Handling And Transport

    FAST 35 FAST 60 FAST 95 FAST 110 Thermal input 46,8 71,1 93,0 104,6 kcal/h 40.300 61.200 80.000 90.000 Thermal output 42,2 64,4 83,9 94,2 kcal/h 36.300 55.400 72.100 81.090 Efficiency 90,1 90,5 90,1 90,1 Combustion chamber volume 48,8 77,4...
  • Page 12 The heaters must only be handled by personnel If using a fork lift make sure that the fork is inserted properly equipped with machinery capable of handling correctly in the slots between the side supports. the weight of the heater. BEWARE! When moving the heater manually, make sure there is When handling or moving the heater it is important to...
  • Page 13 • that it must be positioned in a room with air When installing the FAST heater it is important to ventilation according to the Laws in force. keep in mind that : •...
  • Page 14: Fixed Protections

    Inclination Of flaps DUCTING It is possible, by ducting, to send some of the hot air to other rooms through a hole ( ∅ 150 for the models FAST and ∅ 300 for the models 35/60 FAST 95/110) situated on the superior panel on of the head.
  • Page 15: Control Board

    The heater is equipped with an electrical board, a fan For the connections use the socket positioned motor, thermostats and a burner already connected: externally according to the specific electrical diagram. Therefore connections concern general electrical feeding system. 1. 3 pin plug 2.
  • Page 16 CAPTION Voltage indicator Burner terminal board Limit indicator Burner Burner lock-out indicator MGV Fan terminal board Heating / stop / fan switch Fan group Room thermostat Outside socket Limit thermostat IMT* Magnetic switch Fan thermostat External piece – Not supplied with the heater TANK...
  • Page 17 The FAST heater is equipped with a tank that not necessarily must be installed inside the heater (if the tank is positioned far away we can supply a closing panel) 1. Closing panel 2. Tank FILLING THE TANK • Take off the burner panel •...
  • Page 18: Starting And Stopping

    Electrical Burner Pump Delavan model feed head regulation pressure Nozzle regulation (bar) (G.P.H) 230V 50Hz ∼ FAST 35 REG 5 1.00 60°W 230V 50Hz ∼ FAST 60 R40G10S 1.50 60°W 230V 50Hz ∼ FAST 95 R40G10S 1.75 60°W 230V 50Hz ∼...
  • Page 19: Maintenance

    • Check the fan stops automatically Starting the heater for the first time: • Close the room thermostat contact: the burner starts its cycle and following the pre-purge the flame ignites ATTENTION • When starting for the first time it is possible that the Check that the fan starts one minute after burner stops because fuel does not immediately flow...
  • Page 20 We suggest to clean the heat exchanger at least once a year. Please follow the instructions below: FAST 35/60 • Remove the rear panel. • Remove the fixing screws of inspection panels.
  • Page 21 SERVICING Installment, starting and maintentance operations for If you need help for maintenance or repairs please the KONGSKILDE air heaters shall be carried out by directly contact KONGSKILDE Technical Service, who qualified technicians. will address you to the nearest Servicing Agency.
  • Page 22 MALFUNCTIONS, CAUSES AND The burner switches off REMEDIES when working regularly even when the room temperature is lower than the temperature set on the thermostat MALFUNCTION PROBABLE CAUSE RECOMMENDED REMEDIES The burner does not start No power Check position of general power switch Check the line Check connections...
  • Page 23 Faulty thermostat Replace the thermostat Replace or integrate with an appropriately rated appliance The thermal power of the heater is The heater operates continuosly insufficient to heat the environment without reaching the required temperature Adjust to the power indicated in the chart The fuel consumption is lower than normal The heat exchanger is dirty...
  • Page 24 Please note that all details and specifications contained herein are correct at the time of going to print. However, due to continuous technical improvement, KONGSKILDE A/S reserves the right to change specifications at any time without prior notice. Always consult the data plate on the heater.

Table of Contents