Advertisement

Quick Links

DIGITAL THERMOMETER
MODEL: KFT-03/KFT-04
User manual
V1.4
Appreciate for you to purchase the
product. In order to use the product
properly, please read the instruction
carefully. And Keep it in hand to check.
In order to use the product exactly,
please read and take a full understand
the safety precautions in this
instruction.
Expected use. The body temperature
measured is displayed through thermistor.

Safety Precaution

Represented in the instructions for warning signs,
its purpose for you is to use this product fully and
correctly, and prevent the harm to you and others.
Warning signs and the meaning as following.
Incorrect use will cause the possibility of
Caution
casualties.
Incorrect use will cause the possibility of
casualties or damage of goods.
*The damage of goods are are refers to the relevant housing,
property and livestock, pet damage.
SIGNS
Said notice, the attention of the specific content
in' 'or near, in words or pictures. (left mark) said
'note burst'.
Said prohibits, the prohibits of the specific content
in' 'or near, in words or pictures. (left mark) said
'general prohibition'.
Said must obey, the obey of the specific content
in' 'or near, in words or pictures. (left mark) said
'general imperative'.
IP54
Dust protection and Waterproof level.
Please refer to the instruction manual.

SPECIFICATION

-Model No.: KFT-03/KFT-04
-Display: LCD,3.5digits, 16mmx7mm
-Temperature measurement: thermistor
-Apply for: Oral / Axillary / Rectal
-Temperature measuring time: 1 minute
-Accuracy: ±0.1℃ (±0.2℉)
-Resolution: 0.1℃ (0.1℉)
-Measurement scope:
32.0℃~42.9℃ (90.0℉~109.9℉)
Temperature<32.0℃ (90.0℉) display L℃ (L ℉)
Temperature>42.9℃ (109.9℉) display H℃ (H℉)
-Waterproof level: IP54
-Memory records: 1 set
-Low voltage Indication
-Automatically turn-off function (8 min)

NOTICE BEFORE THE MEASUREMENT

When the room temperature is above 34℃ (93.2℉), Please use the wet towel to cool the test parts before
the measurement.
When measured in the mouth and armpit
Please keep quiet in the following occasions
to get the correct temperature. Otherwise,
it will cause error.
After you get up, the body's temperature will rise
quickly, Please wait for a moment then test the
body's temperature.
Please test the body's temperature 30 minutes
later after sports and bath.
Please test the body's temperature 30 minutes
later after diet.
Measurement for children's temperature
It's best to measure the armpit temperature when
taking a child's temperature.
It's best to measure the armpit temperature when
the child is in sleeping.
Measurement when the child is sitting.
Measurements must be made by an adult with the
thermometer clamped between the arms to prevent
movement.
BODY TEMPERATURE MEASUREMENT
1.Press ON/OFF button to activate. The unit Would beep and display
This LCD display test will go on for around 2 seconds.
2.Then,the temperature taken last time would be displayed with
a "M" mars in the right corner.
3.When "Lo" and flashing ℃(℉) displays, the thermometer is ready for
temperature measuring.
4.The beep will sound when temperature measuring is complete.
5.Pres ON/OFF button of the unit. (The unit will automatically power off after
approximately 8 minutes after use.)
6.(For ℉ and ℃ switch function, hold the button for 3 seconds when turning on.)
PACKING: Your device is safe from damage during transport
packaging. Packaging and raw materials can be reused
or recycled circuit.
DEVICE: Do not disposal the device with your normal household
waste in the end of its life. Enquire about the options for
environmentally-friendly disposal.
BATTERY: Used batteries do not belong in household waste.
The batteries must be returned to a collection point for used
batteries.
Interference may occur In the vicinity of equipment marked with
the following symbol.
Type BF equipment.

HEALTH PRODUCT WARRANTY OF COCET

1.We will be offered one-year free warranty after you buy the health
product of COCET.
2.Free maintain won't be given under the following circumstance:
*The damage caused by dismantle or refit without authorized.
*The breakdown, row harm or damaged because of the move or drop.
*The damage caused by lack of maintain.
*The breakdown caused by the manipulation that hasn't follow the
requests of the Manual.
*The damage caused by the improper repair of a non-our-company
authorized store.
3.We will charge the cost to you when you need the repair service
beyond warranty.
4.Please take the product to sales point when you need the service of
warranty.
5.If it is necessary, you can ask our technicians to provide the circuit
diagram and the data of repairable components when you make the
service of warranty.
KANGFU MEDICAL EQUIPMENT FACTORY
Address: NO. 380 Ningkang East Road,
Yueqing City, Zhejiang Province, China.
Tel: 0577-62579668
Web: www.cocet.com.cn
Email: cocet@cocet.com.cn
Luxus Lebenswelt GmbH
Kochstr. 1, 47877, Willich, Germany
0049-1715605732
Year of Manufacture: See Product Label
-Validity: 3 years, (Battery not included)
-Power source and voltage: DC 1.5V, LR41 or AG3
-Battery life: Approx. 1200 times or 1 year
-Dimension: 128mm×19mm×11mm
-Unit weight: Approx. 9.4g including battery
-Work environment:
Temperature: 5℃~40℃ (41℉~104℉);
Humidity: 15%RH~85%RH;
Atmospheric pressure: 70KPa~106KPa;
-Transport/Storage condition:
Temperature: -20℃~55℃ (-4℉~131℉);
Humidity: 10%RH~85%RH;
Atmospheric pressure: 70KPa~106KPa;
*if there is any specification change for the product,
without prior notice.
Measurement in Oral
The following occasions will cause the body's
temperature rises or fails and will get the
incorrect temperature.
Please measurement 30 minutes later
after smoking.
Please don't drink the cold or hot drinks in
30 minutes before measurement.
Measurement in the armpit
The following occasions will cause the
underarm sweat and will get the incorrect
temperature.
Stay in the bed with covers too much time.
Please use dry towel to wipe the underarm
sweat before the measurement.
Clamp the armpit too much time.
Please use dry towel to wipe the underarm
sweat before the measurement.
In 30 minutes after diet.
Please use dry towel to wipe the underarm
sweat before the measurement.
SIGNS
after-sale service center

TAKING AN ORAL TEMPERATURE

1.Place the probe tip under the tongue
as near as possible to the heat pocket.
LCD up
Heat pocket
The side up
Bi-Bi-Bi-Bi
2.Approximate
measuring time: 1 minute.
Please keep quiet in measurement process
to keep the precisely measurement. It is
recommended to continue measuring for
about 10 seconds after the digital
thermometer alarm then remove.

TAKING A RECTAL TEMPERATURE

Apply a water-soluble lubricant to the probe cover. Gently insert the probe (0.5to 1
inch) into the rectum. Never try to force the thermometer past any resistance. Hold the
thermometer in place until the beep sounds.
Approximate measuring time: 1 minute.

REPLACING THE BATTERIES

Replace the battery as is shown:
The symbol is displayed
together with other ones
and flashing as frequency of 1Hz, the buzzer
alarm will be invalid and no measurement display.
If any of the above-mentioned circumstances
occurs, please exchange the battery avoid the
temperature error.
If do not use the product for a long time (more
than 90 days).
Please take out the battery for safekeeping.
Please dispose of the discarded batteries in
accordance with the relevant environmental
protection regulations of the city.

WARNING

It is very dangerous for the self judgment and treatment that
only by the measuring result, so please be sure to follow the
doctor's instruction.
*Self judgment could result in deterioration.
Please use simple disinfection in medical alcohol on after
use.
A hot bath, long exposure by the sun and strenuous exercise
should not be measured immediately, otherwise it may cause
the measured value to be higher than the actual temperature.
After sleep with water pillow or water sac or just back home
in winter, if take the measurement immediately may get the
measurement result to be low.
No not disassemble and repair your thermometer at will.
No not place the thermometer in a place that is prone to
splashing, high temperature, humidity, direct sunlight,
dust, or corrosion. This product can not be used in the
above environment.
At the end of the service life of this product, do not discard
it together with furniture garbage. Please hand over used
batteries to the appropriate recycling point according to
national and local regulations.

CONTRAINDICATIONS

*When the child himself measures, it may lead to
accidental injury.
*Accidentally swallowed the battery, please contact the
doctor immediately.
*Please don't use if the after swimming, bathing.
*Measurement sites such as inflammation, trauma,
postoperative local lesions can not be used.

ADVICE

*Please don't use this product in any other position except Oral
Axillary and Rectal.
*Please don't collide,break,tread and shake the body of product.
*Please don't use this product in the environment with serious
electromagnetic interference.
*Please don't dismantle,repair and reform the product.
*Please note don't let the liquid (alcohol,drip,hot water and so on) into.
*All the operate without follow advice will lead to the incorrect result
of test.
*Cleaning and disinfection methods: Before and after the use of a
75 % alcohol cotton ball to wipe the probe area of the thermometer,
dry with a soft cloth. Clean the thermometer regularly once a month.

PARTS NAME

TAKING AN AXILLARY TEMPERATURE

1.Place the probe in the middle of the
armpit, up to resist and clamp.
If the thermometer is placed
from above, it will not be able to
reach the center of the armpit.
If the thermometer is placed
landscape position ,
the sensor will reveal.
The test point of the
center of the armpit
2.Approximate
measuring time: 5 minutes.
Please keep quiet in measurement process
to keep the precisely measurement. It is
recommended to continue measuring for
about 30 seconds after the digital
thermometer alarm then remove.
The replace method of battery
1. Place the thermometer back up and pull-out
the battery cover.
2. Take out the battery by a tool and replace the new one.
3. Put back the battery cover.
Bi-Bi-Bi-Bi

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KFT-03 and is the answer not in the manual?

Questions and answers

Summary of Contents for COCET KFT-03

  • Page 1 Please hand over used Expected use. The body temperature batteries to the appropriate recycling point according to HEALTH PRODUCT WARRANTY OF COCET measured is displayed through thermistor. national and local regulations. 1.We will be offered one-year free warranty after you buy the health CONTRAINDICATIONS product of COCET.
  • Page 2 Inquire at where P is the maximum output power COCET for details on this measurement data. We reserve the right to make technical and design changes in rating of the transmitter in watts (W) the course of continuous product improvement.
  • Page 3 Gebruiksaanwijzing Mat Care Zwangerschapstest Strip Lees deze gebruiksaanwijzing aandachtig door, voordat je de test uitvoert • Vang wat urine op in een schoon, droog bakje (afbeelding 1/2). Let op: gebruik ochtendurine als je vóór de menstruatiedatum test. • Haal de test uit het witte sachet. •...
  • Page 4 Afhankelijk van aantal per verpakking: Opvangbakje voor urine Klok of timer voor de wachttijd Wat te doen bij een negatief resultaat? Als het resultaat negatief is (1 lijn), is er geen hCG waargenomen en ben je waarschijnlijk niet zwanger. Het kan zijn dat je te vroeg getest hebt of je kunt je hebben een week uitblijft en je nog steeds een negatief testresultaat ondervindt, is het verstandig contact op te nemen met je huisarts.

This manual is also suitable for:

Kft-04

Table of Contents