1. Safety instructions 1.1 General safety instruction These operating instructions apply to the UAC 30-RF device. These machines are to be handled solely by personnel qualified according to EN 60204-1. The enclosed, separate safety instructions are to be strictly observed.
Explanation of symbols Caution! Be sure to read this! This information is crucial to warranting the product’s function. Failure to observe may result in a defect. Safety instruction / warning This information serves achieving safe operation. If you fail to observe it, the operator’s safety will not be warranted.
2. Commissioning 2.1 Prior to commissioning Verify mains voltage. The voltage of the power supply has to match the details on the rating plate. § Check the tool before use. § The tool must be mounted centrically and positioned at the stop. §...
Switching off Pressing the ON/OFF switch unlocks it so the machine turns off. 2.3 Technical data Supply voltage (see spare part list) 230V 50/60 Hz Power input 500 W Power output 300 W Idle speed 3 500 – 30 000 min -1 Max.
After a cooling time of approx. 10-20 sec., the machine is ready to operate again. Switch it of and on again to reactivate the electronic constant-speed control. When the device is at operating temperature, the temperature-dependent overload protection will react sooner. 3.2 Insertion tools Only use insertion tools whose maximum permissible rotation speed is equal to or higher than the idle speed of the device.
The grinding tools must rotate perfectly true. Do not continue to use out-of- true. Test run! Check grinding tools prior to using them. The grinding tool must be mounted perfectly and rotate freely. Perform test run without load for at least 30 seconds.
4. Maintenance / service 4.1 Preventive maintenance 4.1.1 Changing the brush Unplug power supply prior to any maintenance work. The machine is equipped with two carbon brushes. Change the brushes as follows: Fig. 1 Fig. 2 Unscrew fastening screw (Pos. 23) Pull the switch cap (Pos.2) back a little.
4.3 Repair Should the unit should ever fail, despite careful manufacturing and testing, have it repaired by an authorized service centre. If it is necessary to replace the power cable, this must be done by the manufacturer or his representative in order to avoid any safety hazards. There shall not be any warranty claims in case of damage / consequential damage caused by abnormal handling, improper use, failure to observe the maintenance and services instructions as well as handling by non-...