Bosch WIW28302GB User Manual And Installation Instructions page 40

Table of Contents

Advertisement

en Cleaning and servicing
Since water may remain in the
1.
drain pump, unscrew the pump
cap carefully.
The filter insert in the pump
housing may become stuck due
to coarse particles of dirt.
Loosen the dirt and remove the
filter insert.
Clean the interior, the thread on
2.
the pump cap and the pump hous-
ing.
Ensure that the impeller in the
3.
drain pump can rotate.
40
Screw the pump cap as far as it
4.
will go.
90°
The handle on the pump cap must
be in a vertical position.
Insert the pump cap and screw it
5.
on as far as it will go.
90°
The handle on the pump cap must
be in a vertical position.
Install the base panel.
6.

Advertisement