Argo-Hytos TSE3-D Operating Instructions Manual

Electronic pressure switch

Advertisement

Quick Links

Operating instructions - Electronic pressure switch
TSE3-D
Contents
1 Preliminary note ............................................................................................................................................ 1
1.1 Symbols used ........................................................................................................................................... 1
2 Safety instructions ........................................................................................................................................ 1
3 Functions and features .................................................................................................................................. 2
3.1 Applications ............................................................................................................................................. 2
4 Function ......................................................................................................................................................... 2
4.1 Communication, parameter setting, evaluation ................................................................................... 2
4.2 Switching function .................................................................................................................................. 2
4.3 Analogue function .................................................................................................................................. 3
4.4 IO-Link ...................................................................................................................................................... 3
5 Installation ..................................................................................................................................................... 3
6 Electrical connection ..................................................................................................................................... 4
7 Operating and display elements .................................................................................................................. 4
8 Menu .............................................................................................................................................................. 5
8.1 Menu structure: main menu ................................................................................................................... 5
8.2 Explanation of the menu ........................................................................................................................ 5
8.2.1 Explanation of the menu level 1 ....................................................................................................... 5
8.2.2 Explanation of the menu level 2 ....................................................................................................... 6
9 Parameter setting ......................................................................................................................................... 6
9.1 Parameter setting in general ................................................................................................................. 6
9.2 Configure display (optional) .................................................................................................................. 8
9.3 Set output signals ................................................................................................................................... 8
9.3.1 Set output functions .......................................................................................................................... 8
9.3.2 Define switching limits for the hysteresis function ........................................................................ 8
9.3.3 Define switching limits for the window function ........................................................................... 8
9.3.4 Scaling of the analogue value .......................................................................................................... 8
9.4 User settings (optional) .......................................................................................................................... 9
9.4.1 Set delay for the switching outputs ................................................................................................. 9
9.4.2 Set output logic for the switching outputs ..................................................................................... 9
9.4.3 Set damping for the switching signal .............................................................................................. 9
9.4.4 Damping for analogue output .......................................................................................................... 9
9.4.5 Zero-point calibration ........................................................................................................................ 9
9.4.6 Read min/max values for the system pressure ................................................................................ 9
9.4.7 Reset all parameters to factory setting ............................................................................................ 9
9.4.8 Set colour change of the display ...................................................................................................... 9
9.4.9 Graphical depiction of the colour change of the display ..............................................................10
10 Operation ..................................................................................................................................................11
10.1 Read set parameters ...........................................................................................................................11
10.2 Self-diagnosis / error indications .......................................................................................................11
11 Technical data and scale drawing ............................................................................................................12
11.1 Setting ranges .....................................................................................................................................12
11.2 Further technical data .........................................................................................................................12
12 Factory setting ..........................................................................................................................................12

1 Preliminary note

Symbols used

1.1
Instructions
>
Reaction, result
[...]
Designation of keys, buttons or indications
Cross-reference
Important note
Non-compliance may result in malfunction or interference
Information
Supplementary note
2 Functions and features
› Please read this document prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions.
› If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property can occur.
› Check the compatibility of the product materials with the media to be measured in all applications.
› Correct condition of the device for the operating time can only be guaranteed if the device is only used for media to which the wetted
materials are sufficiently resistant → 3.1 Applications.
The responsibility whether the measurement device is suitable for the respective application lies with the operator.
The manufacturer assumes no liability for consequences of misuse by the operator.
Improper installation and use of the devices result in a loss of the warranty claims.
Page 1
More information at www.argo-hytos.com
Subject to change · TSE3-D_9193_1en_09/2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TSE3-D and is the answer not in the manual?

Questions and answers

Summary of Contents for Argo-Hytos TSE3-D

  • Page 1: Table Of Contents

    The responsibility whether the measurement device is suitable for the respective application lies with the operator. The manufacturer assumes no liability for consequences of misuse by the operator. Improper installation and use of the devices result in a loss of the warranty claims. Page 1 More information at www.argo-hytos.com Subject to change · TSE3-D_9193_1en_09/2019...
  • Page 2: Functions And Features

    FE = window When set to the window function the set and reset points have a fixed hysteresis of 0.25 % of the final value of the measuring span. Strana 2 More information at www.argo-hytos.com Subject to change · TSE3-D_9193_1en_09/2019...
  • Page 3: Analogue Function

    In addition communication is possible via a point-to-point connection with a USB adapter cable. Further information about IO-Link at www.argo-hytos.com → „Products“ → „Pressure Switches“ → „TSE3-D“. Device-specific information You can find the IODDs necessary for the configuration of the IO-Link unit and detailed information about process data structure, diagnostic information and parameter addresses at www.argo-hytos.com →...
  • Page 4: Electrical Connection

    - Setting of the parameter values (scrolling by holding pressed; incremental by pressing once). 12: Alphanumeric display, 4 digits - Display of the current system pressure. - Indication of the parameters and parameter values. Strana 4 More information at www.argo-hytos.com Subject to change · TSE3-D_9193_1en_09/2019...
  • Page 5: Menu

    Analogue end point for system pressure: measured value at which 20 mA / 10 V are provided. AEP2 Prerequisite: OUT2 setting is [I] or [U]. Extended functions / opening of menu level 2. Page 5 More information at www.argo-hytos.com Subject to change · TSE3-D_9193_1en_09/2019...
  • Page 6: Explanation Of The Menu Level 2

    If [C.Loc] is displayed when an attempt is made to modify a parameter value, a parameter setting process is active via the IO-Link communication (temporary locking). If [S.Loc] is displayed, the sensor is permanently locked via software. This locking can only be removed with a parameter setting software. Strana 6 More information at www.argo-hytos.com Subject to change · TSE3-D_9193_1en_09/2019...
  • Page 7 • Leaving the menu level To leave the menu level: ► Press [▲] + [▼] simultaneously. > Menu level 2 changes to level 1 or level 1 changes to display. Page 7 More information at www.argo-hytos.com Subject to change · TSE3-D_9193_1en_09/2019...
  • Page 8: Configure Display (Optional)

    ► Select [AEP2] and set the value at which 20 mA / 10 V is provided. Minimum distance between ASP2 and AEP2 = 20 % of the measuring span (scaling factor 5). Strana 8 More information at www.argo-hytos.com Subject to change · TSE3-D_9193_1en_09/2019...
  • Page 9: User Settings (Optional)

    ► Select [cFL] and set the lower limit value (only possible when [r-cF] or [G-cF] were activated). > The setting range corresponds to the measuring range and its maximum limit is [cFH]. Page 9 More information at www.argo-hytos.com Subject to change · TSE3-D_9193_1en_09/2019...
  • Page 10: Graphical Depiction Of The Colour Change Of The Display

    OUT1 / OUT2 Measured value outside FL1 ... FH1 Measured value outside FL1 ... FH1 and FL2 ... FH2; and FL2 ... FH2; Display = red Display = green Strana 10 More information at www.argo-hytos.com Subject to change · TSE3-D_9193_1en_09/2019...
  • Page 11: Operation

    ► Contact the manufacturer. Err flashes Internal fault / malfunction. *) F = fault W = warning **) The output remains deactivated as long as the excessive current / short circuit continues. Page 11 More information at www.argo-hytos.com Subject to change · TSE3-D_9193_1en_09/2019...
  • Page 12: Technical Data And Scale Drawing

    Ambient temperature: -25 ... +80 °C in case of cULus -25 … +60 °C Medium temperature: -25 ... +80 °C Further technical data and scale drawing at: www.argo-hytos.com 12 Factory setting Factory setting User setting 25% MEW*** 23% MEW*** 75% MEW***...