Download Print this page

Samlexpower SDC-30 Instruction Manual page 2

24 vdc to 12vdc converter

Advertisement

SPECIFICATIONS
CAUTION! : THERE IS NO ISOLATION BETWEEN THE INPUT AND THE OUTPUT.
INPUT AND OUTPUT HAVE A COMMON NEGATIVE
Input to output isolation
Input voltage
Output voltage
Output voltage regulation
Input current at no load
Output current
Continuous
Current limit *
*Note: In current limit condition, the output voltage will drop if the
current drawn increases beyond the current limit value of 35 A
Output ripple and noise
Efficiency
Operating ambient temperature -
Humidity
Protections:
- Overload
- Cooling
- Over heating
- Reverse polarity
- Over voltage
Input side fuse
Safety and EMC Standards:
- Emission
- Immunity
- Automotive directive
Input / output connections
Weight
Dimensions (H x W x D)
Warranty
NOTE: Specifications are subject to change without notice
SDC30-August2006
Not isolated. Input and output connections have a common negative
20 to 32 VDC
13.8 VDC ± 0.1 V
Less than 3%
25 mA
30 A
35A
less than 50 mV RMS
Approx. 92%
o
-20 to +30
C (derate linearly to zero at 70º C)
Max. 95%, non condensing
By current limiting
Temperature controlled fan
Drop in output voltage
Fuse protection, 30 A
Varistor (also protects against load dump)
30 A (inside the unit)
EN50081-1
EN50082-1
95/45/EC
Terminal Block - 6.3 mm male flat tab, quick connect
1.5 lbs / 0.6 Kg
1.9" x 3.5" x 5.9" / 49 x 88 x 151 mm
2 years
Samlex America Inc.
110-17 Fawcett Road
Coquitlam BC Canada V3K 6V2
Telephone: (604) 525-3836

Advertisement

loading

This manual is also suitable for:

06174