Indoor model
Function
Indoor unit power supply
w
Capacity
Air flow(High/Med. /Low )
Power outlet
Running current
Power input
Power factor
Starting current
Fan motor current
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Air direction
w
Sound level(High/Med. /Low )
w
Fan speed(High/Med. /Low )
Fan speed regulator
Thermistor RT11(at25:)
Thermistor RT12(at25:)
Outdoor model
Outdoor unit power supply
Capacity
Dehumidification
Outdoor air flow
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Compressor motor current
Fan motor current
Coefficient of performance(C.O.P)
Model
Output
Winding
resistance(at20:)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Sound level
Fan speed
Fan speed regulator
Refrigerant filling
capacity(R22)
Refrigerating oil (Model)
Thermistor RT61(at0:)
NOTE: Test conditions are based on ISO 5151.
Cooling : Indoor DB27°C WB19°C
Outdoor DB35°C WB24°C
Indoor-Outdoor piping length 5m
w Reference value
MSC-07RV -
MSC-07RV -
Cooling
Single phase
220-240V,50Hz
w
w
K /h
474/384 /294
A
A
0.17
W
%
93.6-85.8
A
A
0.17
RC4V19-LA
WHT-BLK 413
"
BLK-RED 334
mm
850O278O191
kg
w
w
w
dB
36/31 /26
w
w
rpm
950/790 /640
k"
k"
MUH-07RV -
Single phase
220-240V,50Hz
kW
2.2
R/h
0.8
K /h
1620-1752
A
A
3.13-3.03
W
675-715
A(kW)
%
98.0-98.3
A
A
2.92-2.81
A
0.21-0.22
3.10-2.93
RH-130VGCT
W
650
C-R 4.18
"
C-S 5.76
RA6V23-FB
WHT-BLK 353
"
BLK-RED 321
mm
788o540o255
kg
dB
rpm
710-760
kg
0.85
cc
300 (MS56)
k"
33.18
MSC-09RV -
E4
MSC-09RV -
E5
Heating
Cooling
Single phase
220-240V,50Hz
w
w
w
w
504/414 /336
474/384 /294
10
35
93.6-85.8
RC4V19-LA
WHT-BLK 413
BLK-RED 334
850O278O191
9
5
w
w
w
35/30 /26
36/31 /26
w
w
w
w
1000/850 /710
950/790 /640
3
10
10
MUH-09RV -
E4
Single phase
220-240V,50Hz
2.5
2.5
1.1
1620-1752
10
2.98-2.88
3.93-3.83
645-685
845-885
98.4-99.1
97.7-96.3
25
2.77-2.66
3.72-3.61
0.21-0.22
3.68-3.47
2.84-2.72
RH-165VGCT
C-R 3.30
C-S 5.80
RA6V23-FB
WHT-BLK 353
BLK-RED 321
780o540o255
33
47
710-760
1
300 (MS56)
Heating : Indoor
Outdoor DB 7°C / WB 6°C
12
MSC-12RV -
E4
MSC-12RV -
E5
Heating
Cooling
Single phase
220-240V,50Hz
w
w
w
w
504/414 /336
588/468 /360
10
0.17
35
0.17
RC4V19-GA
WHT-BLK 375
BLK-RED 294
850O278O191
9
5
w
w
w
w
35/30 /26
39/34 /29
w
w
w
1000/850 /710
1020/850 /690
3
10
10
MUH-12RV -
E4
Single phase
220-240V,50Hz
3.1
3.4
1.6
1656-1758
10
4.13-3.93
5.56-5.71
885-905
1180-1260
97.4-95.9
96.5-91.9
25
3.92-3.71
5.27-5.39
3.37-3.30
2.79-2.62
RH-220VHAT
800
RA6V33-DB
WHT-BLK 301
BLK-RED 332
780o540o255
33
47
1
0.85
520 (MS56)
33.18
DB20°C
E4
E5
Heating
w
w
w
642/516 /402
10
0.19
40
95.7-87.7
0.19
10
5
w
w
w
39/34 /29
w
w
w
w
1100/920 /750
3
10
10
E4
4.0
10
5.76-5.91
1220-1310
96.3-92.4
35
5.47-5.59
0.29-0.32
3.17-2.96
1050
C-R 2.13
C-S 3.91
38
49
810-840
1
1.19
33.18