Download Print this page

Norgren NC-MP-4A4B-12DLA/AL1403 Operation Manual

Io link master profinet

Advertisement

Quick Links

Operation Manual
IO Link Master - PROFINET
NC-MP-4A4B-12DLA/AL1403
Before starting work read these instructions.
This manual contains proprietary information. No part of this
publication may be reproduced, transcribed or transmitted
in any form without the written consent of the publisher.
Every effort has been made to ensure that the information
contained in this manual is accurate. All rights reserved.

Advertisement

loading

Summary of Contents for Norgren NC-MP-4A4B-12DLA/AL1403

  • Page 1 Operation Manual IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 Before starting work read these instructions. This manual contains proprietary information. No part of this publication may be reproduced, transcribed or transmitted in any form without the written consent of the publisher.
  • Page 2 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 Contents 1. Preliminary note 1.1. Legal and copyright information 1.2. Purpose of the document 1.3. Explanation of Symbols 1.4. Modification history 2. Safety instructions 2.1. General 2.2. Required background knowledge 2.3. Safety symbols on the device 2.4.
  • Page 3 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 9.1.4. IoT: Configure the interface to LR AGENT or LR SMARTOBSERVER 9.1.5. Fieldbus: Configure IP settings 9.1.6. IO-Link ports: Activate data transfer to LR AGENT or LR SMARTOBSERVER 9.1.7. IO-Link ports: Set the operating mode Pin 2 (UA) 9.1.8.
  • Page 4 1.1. Legal and copyright information © All rights reserved by IMI Norgren. No part of this manual may be reproduced and used without the consent of IMI Norgren. All product names, pictures, companies or other brands used on our pages are the property of the respective rights owners: •...
  • Page 5 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 1.3. Explanation of Symbols WARNING Warning of serious personal injury. Death or serious irreversible injuries may result. CAUTION Warning of personal injury. Slight reversible injuries may result. NOTICE Warning of damage to property Important note...
  • Page 6 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 2. Safety instructions Content General Required background knowledge Safety symbols on the device Tampering with the unit 2.1. General The plant manufacturer is responsible for the safety of the plant in which the device is installed.
  • Page 7 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 3. Intended use Content Permitted use Prohibited use 3.1. Permitted use The IO-Link master serves as a gateway between intelligent IO-Link devices and the PROFINET network. The device is designed for use without a control cabinet in the plant construction.
  • Page 8 4.1. Parameter setting The device provides the following configuration options: • Parameter setting of the IO-Link master of the NC-MP-4A4B-12DLA/AL1403 with parameter setting software LR DEVICE and/or PROFINET projection software • Parameter setting of the connected IO-Link devices (sensors, actuators) with parameter setting software LR DEVICE and/or PROFINET projection software •...
  • Page 9 The device has a voltage output (XD2) to supply an additional device. This makes it possible to supply several Norgren NC range devices with one voltage source (daisy chain). This device is “powered by ifm”. In all electronic interfaces, this device will OM-IO-Link Master.09...
  • Page 10 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 5. Mounting Content Installing the device 5.1. Installing the device ‣ Disconnect power before installation. ‣ Please observe the maximum tightening torque. ‣ Use a plane mounting surface for installation. ‣ Fix the unit to the mounting surface using 2 M5 mounting screws and washers.
  • Page 11 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 6. Electrical connection Content Notes Connect PROFINET ports IO-Link Port connection Ground the device Connect the device 6.1. Notes A qualified electrician must connect the unit. ‣ The national and international for regulations setting up electrical equipment must be complied with.
  • Page 12 IO Link Master - PROFINET NC-MP-4A4B-12DLA NC-MP-4A4B-12DLA/AL1403 > Connect PROFINET ports 6.2. Connect PROFINET ports ► Connect the device via the M12 socket XF1 and/or XF2 with the ‣ Connect the device via the M12 socket XF1 and/or XF2 with the PROFINET PROFINET network (e.g.
  • Page 13 Wiring Notes: electrically designed for this. • The power supply of the connected IO-Link devices may only be provided via the NC-MP-4A4B-12DLA/AL1403 The additional digital input of ports X5 … X8 (pin 2) meet the requirements of type 2 behavior •...
  • Page 14 NC-MP-4A4B-12DLA IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 > Ground the device 6.4. Ground the device The FE potential is connected to the following points of the device: The FE potential is connected to the following points of the device: Upper mounting lug of the housing •...
  • Page 15 66 / IP 67 (→ Accessories (→ S. 51)). Optional: Supply of additional devices (Daisy chain): Optional: Supply of additional devices (Daisy chain): ‣ Connect additional Master to M12 socket X32 of the NC-MP-4A4B-12DLA/AL1403 (Daisy- ► Connect additional Master to M12 socket X32 of the NC-MP- chain function).
  • Page 16 IO Link Master - PROFINET NC-MP-4A4B-12DLA NC-MP-4A4B-12DLA/AL1403 Operating and display elements 7. Operating and display elements Content Content Overview ............................... 17 Overview LED indicators ............................18 > LED indicators Overview Status LEDs Status LEDs RDY, BF and SF (→ (→ S. 18)) Status LEDs RDY, BF and SF (→...
  • Page 17 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 7.2. LED indicators The device only has the following LED indicators: 7.2.1. Status LEDs The RDY LED shows the status of the gateway. The BF LED (Bus Failure) shows the status of the PROFINET connection. The SF LED (System Failure) shows the status of the system.
  • Page 18 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 7.2.3. Voltage supply The port for the voltage supply (XD1) has the LEDs with the designation US and UA. The LEDs indicate the status of the supply voltage. Status LED Description green Supply voltage US is connected...
  • Page 19 NC-MP-4A4B-12DLA/AL1403 8. Setup When the supply voltages have been switched on, the NC-MP-4A4B-12DLA/AL1403 starts with the factory settings. The LEDs signal the current operating status of the device and the ports (→ LED indicators (→ S. 18)). 8.1. Parameter setting options The device can be configured with the following options: •...
  • Page 20 Firmware: Reboot the device Configure IO-Link devices On delivery, the NC-MP-4A4B-12DLA/AL1403 is configured with the factory settings (→ Factory Settings (→ S. 50)). Required software: LR DEVICE (1.6.x or higher) (Part.-no.: QA0011/QA0012) This device is “powered by ifm”. In all electronic interfaces, this device will OM-IO-Link Master.020...
  • Page 21 An active VPN connection blocks the access of the parameter setting software LR DEVICE to the PROFINET interface of the NC-MP-4A4B-12DLA/AL1403. ‣ Deactivate the VPN connection in order to be able to access the NC-MP-4A4B-12DLA/AL1403 with the LR DEVICE. This device is “powered by ifm”. In all electronic interfaces, this device will OM-IO-Link Master.021...
  • Page 22 For parameter setting with LR DEVICE, the IO-Link master and the PC used for parameter setting must be configured for the same IP address range. To access the NC-MP-4A4B-12DLA/AL1403 with LR DEVICE: 1. Preparations ‣ Install LR DEVICE on the PC (→ User documentation “LR DEVICE”) ‣...
  • Page 23 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 9.1.3. IoT: Configure access rights The access rights define which instance may read and / or write the parameter data, process data and event/diagnostic messages. In order to configure the access rights to the IO-Link master: ‣...
  • Page 24 500 ... 2147483647 [Application Tag] Source identifier of the IO-Link master in the structure of LR AGENT or Factory setting: NC-MP-4A4B-12DLA/AL1403 LR SMARTOBSERVER (String32) After changing the parameter [Port LR Agent or SMARTOBSERVER] or [Application Tag], it may take 120 seconds before the device establishes a new TCP connection.
  • Page 25 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 9.1.6. IO-Link ports: Activate data transfer to LR AGENT or LR SMARTOBSERVER The user can decide separately for each IO-Link port whether the process data of the connected IO-Link devices should be transferred to LR AGENT or LR SMARTOBSERVER.
  • Page 26 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 9.1.8. IO-Link Ports: restrict current intensity For the IO-Link ports X1...X4, the following features can be set: • Max. current intensity of the supply voltage US • Max. current intensity of the supply voltage UA For the IO-Link ports X5...X8, the following features can be set:...
  • Page 27 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 9.1.9. IO-Link ports: Set the operating mode Pin 4 pin 4 of the IO-Link-Ports X1 ... X8 supports the following operating modes: • Disabled: no data transmission to pin 4 (C/Q) of the IO-Link port •...
  • Page 28 [Type compatible V1.1 device with Restore] [Vendor ID] ID of the manufacturer that is to be validated 0...65535 Factory setting: 0# IMI Norgren: 310 [Device ID] ID of the IO-Link device that is to be validated 0...16777215 Factory setting: 0 ‣...
  • Page 29 *... Parameter only changeable, if the connection to the PROFINET controller is closed ‣ Save changed values on the device. 9.1.12. Info: Show device information To read the general information of the IMI Norgren IO-Link master: ‣ Select [Info] menu. > The menu page shows the current settings.
  • Page 30 > The menu page shows the current settings. ‣ Click on [Reboot] to reboot the device. > LR DEVICE reboots the IMI Norgren IO-Link master. This device is “powered by ifm”. In all electronic interfaces, this device will OM-IO-Link Master.030 appear as AL1403.
  • Page 31 2. Add IO-Link device ‣ Under [ONLINE]: Click on the required IO-Link master. > LR DEVICE automatically detects the IO-Link devices connected to the IO-Link master (e.g. IMI Norgren sensor KG5065). 3. Configure IO-Link device ‣ Mouse click on the port to which the IO-Link device is connected.
  • Page 32 ‣ Use the help function of the PROFINET projection software! 9.2.1. Install GSD Files IMI Norgren provides a GSD file to map the IO-Link masters of the AL14 device family in the PROFINET projecting software. The user can download the GSD file from the IMI Norgren website (→ www.IMI-Norgren.com).
  • Page 33 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 9.2.2. Integrate the IO-Link master in the project Using the installed GSD file, the IO-Link master can be added to a project. ‣ Create a new project / open an existing project. ‣ Open the [Devices & networks] view.
  • Page 34 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 9.2.3. Configure the IO-Link master Content IO-Link Master: Set operating mode IO-Link Master: Set the module parameters Access to the configuration of the IO-Link master via the following slots: Slot Description Profile of the IO-Link master...
  • Page 35 > The device catalogue is open. ‣ in the project: Double click on NC-MP-4A4B-12DLA/AL1403 > The window [Device overview] of the NC-MP-4A4B-12DLA/AL1403 appears. ‣ In the device catalogue: Drag the required module from the [Module] folder to slot [1]. > The selected profile is loaded with the preset IOLM proxy module.
  • Page 36 > The device catalogue is open. ‣ in the project: Double click on NC-MP-4A4B-12DLA/AL1403 > The window [Device overview] shows the slot configuration of the NC-MP-4A4B-12DLA/AL1403. ‣ Select slot [1 IOLM proxy]. > The window [Properties] > [General] shows properties of the IO-Link master.
  • Page 37 > The profile of the IO-Link master is set. > The device catalogue is open. > The [Device overview] view of the NC-MP-4A4B-12DLA/AL1403 is activated. ‣ In the device catalogue: Drag the required IOLD proxy module from the [Submodules] folder and drop it on the slot of the port.
  • Page 38 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 IO-Link Ports: Parameter setting The different IOLD proxy modules have specific parameter sets. IOLD proxy modules Port Parameter Digital Input Digital Input Digital Output Digital Output IO-Link Input IO-Link Output IO-Link Input + without PD...
  • Page 39 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 9.2.5. Configure IO-Link devices The NC-MP-4A4B-12DLA/AL1403 supports the configuration of the connected IO-Link devices via the PROFINET application. The configurable parameters depend on the IO-Link device that is used. Configurable parameters of the IO-Link devices: →...
  • Page 40 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 9.2.7. Read I&M datasets I&M0 provide the user with device-specific basic information. This ensures reliable identification of the device, the device’s hardware and software components as well as the manufacturer. The datasets I&M1 to 3 offer the programmer the possibility to store project-specific information on the device.
  • Page 41 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 10. Operation Content Use web-based management 10.1. Use web-based management The device has an integrated web server The web server generates a website with the following data: • Status information of the ports • Diagnostic information of the device •...
  • Page 42 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 11. Maintenance, repair and disposal Content Cleaning process Update the firmware Exchanging the IO-Link device The operation of the unit is maintenance-free. ‣ Dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations when it is no longer used.
  • Page 43 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 11.2. Update the firmware The new firmware is installed via the device’s web interface. ‣ During the firmware update, ensure that the device is connected to the supply voltages US and UA. Before the firmware update: ‣...
  • Page 44 ‣ Disconnect the old IO-Link device from the IO-Link master. ‣ Connect the new IO-Link device with the same IO-Link port of the NC-MP-4A4B-12DLA/AL1403. > The IO-Link master transfers the parameter values from the data memory to the new IO-Link device.
  • Page 45 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 12. Factory Settings In the factory settings, the device has the following parameter settings: Parameter Factory setting [IP address] 0.0.0.0 [Subnet mask] 0.0.0.0 [IP gateway address] 0.0.0.0 [Host name] blank Data Storage empty This device is “powered by ifm”. In all electronic interfaces, this device will OM-IO-Link Master.045...
  • Page 46 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 13. Accessories List of accessories of NC-MP-4A4B-12DLA/AL1403: → www.Norgren.com > Product page > Accessories This device is “powered by ifm”. In all electronic interfaces, this device will OM-IO-Link Master.046 appear as AL1403. All firmware and electronic files are provided by ifm.
  • Page 47 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 14. Appendix Content Technical data PROFINET 14.1. Technical data Content Application Electrical data Inputs/outputs Inputs Outputs Interfaces Environmental conditions Approvals / tests Mechanical data Electrical connection 14.1.1. Application Application Application I/O modules for field applications Daisy-chain function Voltage supply;...
  • Page 48 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 14.1.2. Electrical data Electrical data Operating voltage [V] 20...30 DC; (US; according to SELV/PELV) Current consumption [mA] 300...3900; (US) protection class Additional voltage supply[V] 20...30 DC; (UA) Sensor supply US Total current rating [A] Current rating per port [A] 2;...
  • Page 49 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 NC-MP-4A4B-12DLA NC-MP-4A4B-12DLA > > Derating without daisy chain Derating with daisy chain Derating with daisy chain -30 -20 -10 0 -30 -20 -10 0 10 20 30 40 50 60 10 20 30 40 50 60...
  • Page 50 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 14.1.3. Inputs/outputs Inputs/outputs total number of inputs and outputs 24; (configurable) Number of inputs and outputs Number of digital inputs: 12; Number of outputs: 12 14.1.4. Inputs Inputs Number of digital inputs 12; (IO-Link Port Class A: 4 x 2;...
  • Page 51 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 14.1.6. Interfaces Interfaces Communication interface Ethernet; IO-Link Ethernet Max.current load per output [mA] 2000 Transmission standard 10Base-T; 100Base-TX Transmission rate [MBit/s] 10; 100 Protocol PROFINET IO Factory settings • IP address: 0.0.0.0 • Subnet mask: 0.0.0.0 •...
  • Page 52 Voltage supply IN XD1 IO Link Master - PROFINET Wiring + 24 V DC (US) NC-MP-4A4B-12DLA > Connector M12 (L-coded) NC-MP-4A4B-12DLA/AL1403 GND (UA) 14.1.10 Electrical connection Voltage supply IN XD1 Wiring + 24 V DC (US) GND (US) > GND (UA)
  • Page 53 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 14.2. PROFINET Content Device structure Parameter data Cyclic data Acyclic data 14.2.1. Device structure Slot Subslot Label Description 0x8000 Parameter PROFINET-IO 0x8001 X1 P1 Parameter Port XF1 0x8002 X1 P2 Parameter Port XF2 IOLM proxy →...
  • Page 54 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 14.2.2. Parameter data Content IOLM proxy module Parameters of the IOLM proxy modules IOLD proxy modules Parameters of the IOLD proxy modules IOLM proxy module Module IO-Link Master Proxy Description 8 Ports IO-Link Master Proxy 8P...
  • Page 55 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 Parameters of the IOLM proxy modules Parameter Description Possible values [Enable Port Diagnosis] Enable / disable diagnostic data of the port Disabled disabled Enabled enabled [Port Configuration without Enable configuration of the IO-Link ports via IODD...
  • Page 56 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 IOLD proxy modules Content Port modules: I/O Mode Port modules: Mix Mode Port modules: I/O Mode Module Port Mode Process data IO-Link 1 I / 1 O Byte + PQI IO-Link 1 byte input data and 1 byte output data and PQI...
  • Page 57 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 Port modules: Mix Mode Module Port Mode Process data IO-Link 1 I / 1 O Byte + PQI IO-Link 1 byte input data and 1 byte output data and PQI IO-Link 1 I / 15 O Byte + PQI...
  • Page 58 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 Parameters of the IOLD proxy modules Parameter Description Possible values [Enable Port Diagnosis] Enable / disable diagnostic messages of Disabled disabled the port Enabled* enabled [Enable Process Alarm] enable/disable process alarms Disabled disabled Enabled*...
  • Page 59 128 milliseconds [Vendor ID] ID of the manufacturer that is to be validated 0* ... 65535 ID of the manufacturer of the IO-Link device (Norgren: 310) [Device ID] ID of the IO-Link device that is to be validated 0* ... 16777215...
  • Page 60 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 14.2.3. Cyclic data Content IOLM Proxy: IO Mode IOLM Proxy: Mix Mode IOLM Proxy: Mix Mode with Energy Monitoring IOLD Proxy: IO-Link n I / m O + PQI IOLD Proxy: Digital Output IOLD Proxy: Digital Input...
  • Page 61 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 IOLM Proxy: Mix Mode Input data: 1 byte Byte (offset) Contents Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Port X8: Digital Port X7: Digital Port X6: Digital...
  • Page 62 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 Byte (offset) Contents Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 n+11 Port X1: Actuator Current [mA] (MSB) n+12 Port X1: Actuator Current [mA] (LSB) n+13...
  • Page 63 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 [Supply Voltage Actuator [mV]] voltage value of the supply voltage UA (value in mV) 2 bytes 0x0000 ... 0xFFFF [Supply Current Actuator [mA]] Current intensity value of the supply voltage UA (value in mA) 2 bytes 0x0000 ...
  • Page 64 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 Port modules: I/O Mode Input data: Byte Contents IO-Link input data (n bytes) Port Qualifier Information (→ Mapping: Port Qualifier Information (PQI) (→ S. 72)) Legend: n ... Number of bytes on input data (n = [0, 1, 2, 4, 8, 16, 32])
  • Page 65 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 Mapping: Port Qualifier Information (PQI) DevErr DevComm PortActive SubstDev NewPar res. res. Legend: [NewPar] 1 bit no IO-Link device parameter update detected IO-Link device parameter detected [SubstDev] 1 bit No exchange IO-Link device detected (identical serial number)
  • Page 66 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 14.2.4. Acyclic data Content I&M datasets Diagnostic and alarms I&M datasets The NC-MP-4A4B-12DLA/AL1403 supports the following I&M datasets (I&M = Identification & Maintenance): I&M0 (Slot 0) Variable Description Access Size Vendor ID IO-Link ID of the manufacturer...
  • Page 67 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 I&M3 (Slot 0) Variable Description Access Size Descriptor Description of the device (ASCII, padded with spaces) r/w ... read and write I&M0 (Slot 1) Variable Description Access Size Vendor ID IO-Link ID of the manufacturer...
  • Page 68 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 Diagnostic and alarms ECD code Name Description Type 0x02 EVNT_CODE_M_PDU_CHECK Receive frame with CRC error Alarm 0x1B EVNT_CODE_S_RETRY Repetitions detected Alarm 0x1E EVNT_CODE_P_SHORT Short circuit on C/Q cable detected Diagnostics 0x1F EVNT_CODE_P_SENSOR Error in the sensor supply...
  • Page 69 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 15. Index Accessories General Acyclic data Ground the device Appendix Application I&M datasets Approvals / tests I&M0 (Slot 0) I&M0 (Slot 1) Cleaning process I&M1 (Slot 0) Configuration I&M2 (Slot 0) Configure IO-Link devices 31, 39 I&M3 (Slot 0)
  • Page 70 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 IO-Link supply IOLM Proxy Read and write process data IO Mode Read I&M datasets Mix Mode Remarks Mix Mode with Energy Monitoring Required background knowledge IOLM proxy module Safety instructions Configure access rights Safety symbols on the device...
  • Page 71 IO Link Master - PROFINET NC-MP-4A4B-12DLA/AL1403 Notes This device is “powered by ifm”. In all electronic interfaces, this device will OM-IO-Link Master.071 appear as AL1403. All firmware and electronic files are provided by ifm. 01/21...