Summary of Contents for GenixGreen ES-BOX1

  • Page 1 ES-BOX1 (5120WH) ALL-IN-ONE SOLAR ESS USER MANUAL 3.2KVA INVERTER 5KWH LFP BATTERY...
  • Page 2: Table Of Contents

    CONTENT ABOUT THIS MANUAL........................ CATALOG..........................SCOPE............................SAFETY DESCRIPTIONS ..................... INTRODUCTION........................... FUNCTION..........................BASIC SYSTEM STRUCTURE.................... 3. WIFI CONNECTIVITY INSTALLATION..........................UNPACKING AND INSPECTION..................PREPARE..........................INSTALL UNIT......................... AC INPUT/OUTPUT CONNECTION................... PV CONNECTION......................... FINAL ASSEMBLY......................... OPERATION........................... POWER SWITCH........................OPERATION AND DISPLAY PANEL.................. LCD DISPLAY ICONS......................LCD SETTING........................
  • Page 3: About This Manual

    ABOUT THIS MANUAL CATALOG This manual describes how to assemble, install, operate the units and how to troubleshoot of this unit. Please read this manual carefully before installation and operation. Keep this manual for future reference. SCOPE This manual provides safety guidelines of installation, and the information on tools and wiring. SAFETY INSTRUCTION WARNING: This chapter contains important safety and operating instructions.
  • Page 4 3. On‐grid with energy storage. 4. Configurable AC/Solar Charger priority via LCD setting. 5. Smart battery charger design for optimized battery performance. 6. Compatible to mains voltage or generator power. 7. Overload, over temperature, short circuit protection, fault record, history record. 8.
  • Page 5: Wifi Connectivity

    Product Overview 1.Carry Handle 2.Device switch 3.Battery BMS switch 4.AC Charge Input Port 8.LCD operate touch display 5.AC Output Port 6.PV Charge Input Port 7.Movable wheels screen 3. WIFI Connectivity (Optional) This system come equipped with integrated Wi-Fi capability which makes it very easy to integrate into a home network.
  • Page 6: Installation

    INSTALLATION 4.1 UNPACKING AND INSPECTION Before installation, please inspect the unit. Be sure that everything in the package is not damaged. The following items inside of package would be received. 01.All-in-one solar system 02.User manual 4.2 PREPARATION. Please remove the two screws on the back cover of the device before opening it. 4.3 INSTALLATION SITES SELECTION.
  • Page 7 WARNING!: It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below. Model Gauge Cable (mm2) Torque Value 3.2KVA 8AWG 1.2 Nm WARNING: Because this system is non-isolated, only three types of PV modules are acceptable: single-crystalline, poly crystalline with class A‐rated and CIGS modules.
  • Page 8: Final Assembly

    4.6 FINAL ASSEMBLY After connecting all wires, please put bottom cover back by screwing screws. 5. OPERATION 5.1 POWER ON/OFF Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch(located on the button of the case) to turn on the unit. 5.2 OPERATION AND DISPLAY PANEL The operation and display panel, shown in below chart, it is on the front panel of the system.
  • Page 9: Lcd Display Icons

    1. PV input information Fault indicator 2. Operation information About button 3. CT power 10. History button 4. AC/INV indicator 11. Setting button 5. AC Input /Grid power information 12. Diagram button 6. Charging indicator Battery information 7. AC Output information 5.3 LCD DISPLAY ICONS Icon Description...
  • Page 10 PV voltage ,current and power Battery voltage and current information Indicates the DC/AC inverter circuit is working Parallel status Inverter working status Volume icon CT Power This button includes LCD, inverter, MPPT version, inverter model This button includes generation, event, help The setting button include language, working mode, input, output, battery, charge, PV, parallel, date and time, Grid, peak valley, and other function settings...
  • Page 11: Lcd Setting

    5.4 LCD SETTING After press function button, the unit will enter setting mode. Set password:1155 Illustrate Button Function Main Diagra Display Return to the default display screen Interface Chinese: Chinese display Language English: English Display AC: (default) AC will provide power to the load as the first priority,solar charging the battery.
  • Page 12 AC Width Range: (Default) 120-280Vac Input AC narrow range: 170-280Vac Output Voltage: (Default) 230Vac、220Vac 、240Vac Output frequency: (Default)50Hz 、60Hz Output Battery Type: Lithium battery Bulk charging voltage: 48v mode:56.0vdc(default) setting range:48V to 60V User Floating charge voltage:48v mode:54.0vdc(default) setting range:48V to 60V setting increase or decrease of 0.1V Low Vol Disconnect: 48v mode :44.0vdc(default) Setting range:36v to 50v...
  • Page 13 Total Charge: (default 10A) setting range is 10A to 90A,the increment or decrement is 10A per click. Note: Total Charge=Solar Charging Current+Utility Charging current AC Charge:( default 10A)setting range is 0A to 60A,the increment or Charge decrement is 10A per click. current Note: when the AC charging current is set to ‘0A’, if PV, battery and Utility exist at the same time, the PV will only charge the battery and the...
  • Page 14: Fault Reference Code

    5.5 FAULT REFERENCE CODE Fault code Fault event Bus voltage is too high Inverter voltage is too high Inverter voltage is too low Bus soft start failure Overload fault Output short circuited or over temperature Battery voltage is too low Inverter soft start failure Bus voltage is too low Battery voltage is too high...
  • Page 15: Warning Indicator

    5.6 WARNING INDICATOR Warning code Warning Event Battery voltage is too low Input voltage is too low Input voltage is too high Overload Over temperature Fan is locked when inverter is on Battery voltage is too high PV voltage is too low PV voltage is too high 6.
  • Page 16 Warning code 06 Fan fault Replace the fan Internal temperature of Check whether the environment inverter component is over around the equipment well Warning code 05 100°C ventilated Check if spec and quantity of The battery voltage is too batteries are meet requirements Fault code 07 high Buzzer beeps...
  • Page 17: Specification

    7. SPECIFICATIONS Table 1 Solar Mode Specifications MODEL 3.2KVA Normal DC voltage 48vdc Max PV array power 2500W Rated output power 3200W Max PV open circuit voltage 450VDC PV operating voltage range 120-450VDC PV normal operating voltage 280-360VDC Normal output voltage 230VAC Output voltage range 230 ±...
  • Page 18 Table 2 Line Mode Specifications Input Voltage Waveform Pure Sine wave (AC or generator) Normal Input Voltage 230Vac 120Vac±7V(wide range) Low Loss Voltage 170Vac±7V(narrow range) 130Vac±7V(wide range) Low Loss Return Voltage 180Vac±7V(narrow range) High Loss Voltage 280Vac±7V High Loss Return Voltage 270Vac±7V Max AC Input Voltage 300Vac...
  • Page 19 Table 3 Charge Mode Specifications INVERTER MODEL 3.2KVA Charging Algorithm 3-Step Charging Mode Charging Current 10/20/30/40/50/60Ap (@V =230Vac) Bulk Charging Voltage 48.0-60.0vdc (Default:56 vdc ) Floating Charging Voltage 48.0-60.0vdc (Default:54vdc) Charging Curve Max. charging current(Solar+AC) Over-charging voltage 60vdc Table 4 Battery Specification Type LiFePO4 Nominal Energy...
  • Page 20 Table 5 Inverter Mode Specifications Battery system voltage 51.2V Waveform Pure Sine wave Output Voltage Regulation 230Vac±5% Output Frequency 50/60Hz±1Hz Peak Efficiency ≥90% Power factor 20s@101%~120% load ,10s@121%~150% load, 3- Overload Protection 6s@≥150% load ≤10ms typical (UPS); 20ms typical (Appliances) Transfer time ≤10ms(UPS);...
  • Page 21 Warranty Card Thank you very much for choosing the ES-BOX1 (5120WH). Our company provides you with 3 years warranty period which begins on the date of purchase Warranty: please present the warranty card and fill in the relevant information in detail when a warranty service is requested.