+6282366660856 pH/ORP-3500 pH/ORP Transmitting controller Operation manual V1.1 Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
Page 2
*Without the influence on the operation, any small change or improvement on the products by the manufacturer will not be notified separately. Please make the object as the standard Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
+6282366660856 Ⅰ.GENERAL pH/ORP-3500 series is a kind of popular and cost-effective online pH and ORP controller , with plug-in pH/ORP-1220 sensor, which have good measurement accuracy, anti-interference,easy to install and operation features. White backlight LCD screen,several operations, easy for operation Be compatible for six kinds of buffer solution(10.00,9.18,7.00,6.86,4.00,4.01)
1. Put the instrument in dry environment and the water-drop or moisture will cause the damage or measurement error; 2. Pay more attention on the power supply before wiring connection. Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
Top view Side view 2.1 Installation of instrument pH/ORP-3500 series is adopted panel mounted type, which could be installed easily. Please follow the steps: 1. Put the instrument into the fixed hole 44mmX92mm(HxW) 2. Then push the quick clamp along with the trench and fasten the instrument.
(I+、I-)Instrument mode mA output terminal Connect the receiving terminal of the temp.sensor(red) TEMP-I Connect grounding terminal of the temp. sensor (black) TEMP-G Empty terminal Connect pH or ORP sensor BNC connector Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
+6282366660856 2.3Diagram of 4-20mA output Instrument mode Transmitting mode Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
+6282366660856 2.4 Relay control connection Relay ON/OFF contact component control wiring diagram 2.5 Control mode Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
+6282366660856 2.6Installation of sensor Adapter Connection cap The middle fixed cap (for selection) Chemical probe Sensitive glass membrane (glass bulb) 2.6.1Assembling and replacement Location key Location slot Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
Cause the probe lose effectiveness,pollute the pure water meantime.,make the conductivity under probe downstream of pH probe rise hugely. Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
You could set the relative parameter after connect the instrument and sensor. Please enter into the setting mode to check and set the relative parameters for your first use. These parameters are in different menus. Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
Page 14
◆Measurement mode:Normal display、transient display ◆Setting mode:Parameter setting Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
Some parameters have been set before ex-factory. If the test environment changes (such as replacement of electrode, reset the alarm setting), please check the parameter which is in different menus. The specific content and operations as following: Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
, and save and enter into the next menu setting by pressing 3.2.5 Low-limit alarm setting Same operation as the high-limit alarm setting, and press after setting. Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
3. When the “C10.0” and pH blinks,it means to enter into the buffer solution selection; press “ ”and enter into the next calibration menu. 4. Put the clean sensor into the buffer solution for 3-5 minutes. Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
Press “ ”for 3 seconds under pH measurement status,input the corresponding mV value in different buffer solution, press “ ”to save and enter into the main menu. Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
2. Sensitive glass film (glass bubble) is forbidden to use when the medium with hydrofluoric acid, fluorion and high-concentration sulfion. 3. pH/ORP sensors are not allowed to measure any organic solution which will Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
B. check the connection right or not C. unusual power C. powered by the standard data supply D. reset the transferred volume D. wrong transfer volume Ⅵ、COMPLETE SET Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
P202/203 sensor Channel or reservoir P16 used for submersible installation P202/203 sensor reaction still or material tank P17 used for flange installation Accessories for fold P202/203 sensor Wastewater pool oraeration tank Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...
Page 22
+6282366660856 submersible installation Floating accessories P202/203 sensor Channel, river aquacultural Jacket (protection High temp. glass Bio-pharmaceuticals and part)accessories sensor oodfermentation Noble metal Metallurgy orfloatation system pH/ORP1220B protection sensor Chemitech IT Perdana | Solution For Your Trouble | Service Laboratorium Instrument...