Installation Guide is a supplement to the Blue Brute Installation Guide. ™ ™ 1. ASSEMBLY INSTRUCTIONS 2. INTRODUCTION Proper assembly of Eagle Loc 900RL requires: • Inspect and clean bell, gasket, and spigot • Installing the Insertion Stop on the spigot (Required) •...
Page 7
Figure 2: The end plugs in these pipes keep dirt and other foreign material out of the bell. NOTICE: Eagle Loc 900RL gaskets SHOULD ONLY BE REMOVED OR INSTALLED at a TEMPERATURE ABOVE 40 F. If the gaskets are below that temperature, they should be warmed up prior to installation.
Ensure that the spigot is clean removing all dirt, dust, water, pipe lubrication, etc. Eagle Loc 900RL comes with two assembly mark lines on the spigot end of the pipe. These dual lines indicate the maximum and minimum depth of insertion of the spigot into the bell.
The bell should be braced in order to allow the free end to move laterally under steady pressure using a pry bar or other suitable means. EAGLE LOC 900RL™ INSTALLATION GUIDE UPDATED MARCH 2021...
Page 10
Do not push the spigot farther into the bell as this reduces the rotational flexibility at the joint and causes unnecessary stress on the bell. UPDATED MARCH 2021 EAGLE LOC 900RL™ INSTALLATION GUIDE...
Page 11
CORRECT ASSEMBLY WITHOUT THE JM EAGLE INSERTION STOP Eagle Loc 900RL comes with two assembly mark lines on the spigot end of the pipe. These dual lines indicate the maximum and minimum depth of insertion of the spigot into the bell.
Figure 8 Alternatively, assembly tools may be used that prevent the assembly forces from moving previously installed pipe. Examples of these tools are shown in Figure 9, 10, and 11 on next page. EAGLE LOC 900RL™ INSTALLATION GUIDE UPDATED MARCH 2021...
Page 13
Figure 10: This assembly tool is called the Eagle Claw and is available from Pro Pipe Solutions. Figure 11: This assembly tool uses a chain wrapped around the bell and a lever bar to make the joint. EAGLE LOC 900RL™ INSTALLATION GUIDE UPDATED MARCH 2021...
Page 14
Align the bell and spigot for straight assembly Straight alignment was maintained during assembly Assembly stopped when the spigot contacts the insertion stop Previously assembled pipe did not move when subsequent joints were made UPDATED MARCH 2021 EAGLE LOC 900RL™ INSTALLATION GUIDE...
Page 15
NOTES: EAGLE LOC 900RL™ INSTALLATION GUIDE...
Page 16
NOTES: EAGLE LOC 900RL™ INSTALLATION GUIDE...
Page 17
NOTES: EAGLE LOC 900RL™ INSTALLATION GUIDE...
Page 18
GLOBAL HEADQUARTERS: REGIONAL OFFICE: 5200 West Century Blvd Nine Peach Tree Hill Road Los Angeles, CA 90045 Livingston, NJ 07039 T: 800.621.4404 T: 973.535.1633 F: 800.451.4170 www.JMEagle.com F: 973.533.41785 D E L I V E R I N G G O O D WAT ER T O Y O U UPDATED MAY 2019...
Need help?
Do you have a question about the EAGLE LOC 900RL and is the answer not in the manual?
Questions and answers