i7CxxA-C03-EVK-S1; i7AxxA-C01-EVK-S1 Evaluation Kit Manual for i7A and i7C Non-Isolated DC-DC Series Contents Introduction ........................ 2 Ordering Information ....................2 General Features ....................... 3 Turn-on / Turn-off module by switch ................4 Change Output Voltage ..................... 4 When using external clock (SYNC function only for i7C) .......... 4 Capture output ripple/noise waveform ...............
2. Ordering Information TDK-Lambda offers a wide variety of non-isolated dc-dc power modules in the i7X series. Not every product is currently available in an evaluation kit. The table below includes description and ratings which should help in selecting the most applicable evaluation kit.
3. General Features • Screw Terminals for secured input and output connections • Toggle switch for Remote ON/OFF • Test points / Scope probe hook-ups for ease of measurement • Trim Potentiometer for adjusting the output voltage setting • Component PCB pad provisions for: Input fuse, input inductor, additional input and output capacitance*, output header connector for optional features and signals.
4. Turn-on / Turn-off module by switch Change position of toggle switch”S1” to “CLOSE” turns-on the power supply unit. 5. Change Output Voltage Turn screw on trimmer pot “VR1” to change the output voltage. Turn clockwise to decrease output voltage. Turn counter clockwise to increase output voltage.